Indoor particulate matter (PM2.5) in Malaysian academic building: Elemental characterization and source apportionment

被引:0
|
作者
Isa, Intan Idura Mohamad [1 ]
Abd Wahid, Nurul Bahiyah [1 ]
Jamhari, Anas Ahmad [2 ]
Isa, Irma Izani Mohamad [3 ]
Latif, Mohd Talib [4 ]
机构
[1] Univ Pendidikan Sultan Idris, Fac Sci & Math, Dept Biol, Tanjung Malim 35900, Perak, Malaysia
[2] Univ Sultan Zainal Abidin, Fac Hlth Sci, Sch Biomed Sci, Terengganu, Malaysia
[3] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Biomed Sci, Serdang, Selangor, Malaysia
[4] Univ Kebangsaan Malaysia, Fac Sci & Technol, Dept Earth Sci & Environm, Bangi, Selangor, Malaysia
关键词
PM2.5; aerosols; source apportionment; indoor air pollution; trace metals; water-soluble ionic species; HEALTH-RISK ASSESSMENT; HEAVY-METALS; KUALA-LUMPUR; ROAD DUST; URBAN; PM10; SURFACTANTS; AIR; SCHOOLS; CITY;
D O I
10.1080/15275922.2022.2125106
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aims to determine the elemental compositions of indoor particulate matter (PM2.5) in two selected academic buildings, with emphasis on source apportionment using a multivariate receptor model. PM2.5 samples were collected from lecture halls, laboratories and lecturer offices at the Ministry of Health Training Institute of Sungai Buloh (S1) and the Ministry of Health Training Institute of Sultan Azlan Shah (S2). Sampling took place over 8 h using a low volume sampler (LVS). In this study, various scientific methods such as standard methods for air quality analysis as well as Principal Component Analysis (PCA) and Multiple Linear Regression (MLR) were applied in order to investigate the elemental characterizations and source apportionment of PM2.5, respectively. The PM2.5 compositions for water-soluble ionic species (WSIS) and trace metals were analysed using ion chromatography (IC) and inductively coupled plasma-mass spectrometry (ICP-MS), respectively. Results showed that the mean PM2.5 concentration at S1 (108 +/- 39.5 mu g m(-3)) was higher than S2 (91.1 +/- 36.6 mu g m(-3)). PCA-MLR analysis revealed that biomass burning (48%) and building material/crustal origin (81%) were the major sources of indoor PM2.5 for S1 and S2, respectively. Modifications and improvements to ventilation systems could be implemented in order to maintain a good health of the building occupants as outside sources may contribute to the presence of pollutants in these buildings.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Elemental Composition and Sources of Fine Particulate Matter (PM2.5) in Delhi, India
    S. K. Sharma
    T. K. Mandal
    Bulletin of Environmental Contamination and Toxicology, 2023, 110
  • [42] Characterization and Source Apportionment of PM2.5 Based on the Online Observation in Tianjin
    Xiao Z.-M.
    Xu H.
    Li L.-W.
    Li P.
    Yuan J.
    Tang M.
    Yang N.
    Zheng N.-Y.
    Chen K.
    Huanjing Kexue/Environmental Science, 2020, 41 (10): : 4355 - 4363
  • [43] Source apportionment and elemental composition of PM2.5 and PM10 in Jeddah City, Saudi Arabia
    Khodeir, Mamdouh
    Shamy, Magdy
    Alghamdi, Mansour
    Zhong, Mianhua
    Sun, Hong
    Costa, Max
    Chen, Lung-Chi
    Maciejczyk, Polina
    ATMOSPHERIC POLLUTION RESEARCH, 2012, 3 (03) : 331 - 340
  • [44] Source apportionment of water-soluble organic matter in PM2.5 in Shenzhen
    Sun, Yi-Fei
    Li, Meng-Lin
    Jiang, Jia-Hao
    Dai, Jing
    Gao, Mao-Shang
    Huang, Xiao-Feng
    He, Ling-Yan
    Zhongguo Huanjing Kexue/China Environmental Science, 2020, 40 (05): : 1869 - 1876
  • [45] Does the elemental composition of indoor and outdoor PM2.5 accurately represent the elemental composition of personal PM2.5?
    Brokamp, Cole
    Rao, M. B.
    Fan, Zhihua
    Ryan, Patrick H.
    ATMOSPHERIC ENVIRONMENT, 2015, 101 : 226 - 234
  • [46] Indoor PM2.5 in Santiago, Chile, spring 2012: Source apportionment and outdoor contributions
    Barraza, Francisco
    Jorquera, Hector
    Valdivia, Gonzalo
    Montoya, Lupita D.
    ATMOSPHERIC ENVIRONMENT, 2014, 94 : 692 - 700
  • [47] Indoor air concentrations of particulate matter (PM10 and PM2.5) in German schools
    Fromme, H.
    Dietrich, S.
    Twardella, D.
    Heitmann, D.
    Schierl, R.
    Kiranoglu, M.
    Liebl, B.
    Air Pollution XIV, 2006, 86 : 393 - 399
  • [48] Heavy metals in atmospheric fine particulate matter (PM2.5) in Dhaka, Bangladesh: Source apportionment and associated health risks
    Rahat, Md Masudur Rahman
    Rumman, Riadul
    Ferdousi, Farhana Khanam
    Zhao, Shizhen
    Siddique, Md Abu Bakar
    Zhang, Gan
    Liu, Guorui
    Habib, Ahsan
    ENVIRONMENTAL RESEARCH, 2025, 271
  • [49] Chemical composition of fine mode particulate matter (PM2.5) in an urban area of Delhi, India and its source apportionment
    Sharma, S. K.
    Mandal, T. K.
    URBAN CLIMATE, 2017, 21 : 106 - 122
  • [50] Characteristics and source apportionment of PM2.5 in Jiaxing, China
    Zhipeng Zhao
    Sheng Lv
    Yihua Zhang
    Qianbiao Zhao
    Lin Shen
    Shi Xu
    Jianqiang Yu
    Jingwen Hou
    Chengyu Jin
    Environmental Science and Pollution Research, 2019, 26 : 7497 - 7511