Commutability and interchangeability of commercial quality control materials with feline plasma for common biochemical analytes

被引:10
|
作者
Baral, Randolph M. [1 ,2 ]
Dhand, Navneet K. [2 ]
Freeman, Kathleen P. [3 ]
机构
[1] Paddington Cat Hosp, 210 Oxford St, Paddington, NSW 2021, Australia
[2] Univ Sydney, Fac Vet Sci, Sydney, NSW, Australia
[3] IDEXX Labs Ltd, Wetherby, England
关键词
Biochemistry analyzer; clinical chemistry; linear regression; Passing-Bablok; reference materials; residuals; REFERENCE INTERVALS; CLINICAL-CHEMISTRY; VALUES; SPECIFICATIONS; LABORATORIES; STRATEGIES; GUIDELINES; BREEDS;
D O I
10.1111/vcp.12357
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
BackgroundSpecies-specific plasma or serum pools are considered the ideal standard material for quality control materials (QCM) instead of commercially available human QCM. However, using plasma or serum pools is limited by volume restrictions, degradation over time, and a narrow range of analyte concentrations. Concentrations of QCM analytes should be consistent or commutable with those from species-specific plasma/serum samples, and the precision from plasma pools should be comparable or interchangeable with commercial human QCM. ObjectivesThe aims of this study were to determine the commutability and interchangeability of 2 levels of commercial QCM (MAS chemTRAK-H [CT]) with feline plasma pools (PP) from normal and renal disease cats measured using a commercial laboratory analyzer and a veterinary in-house analyzer. MethodsAgreement between the 2 analyzers was assessed for 16 analytes by correlation and Passing-Bablok regression analyses of feline plasma samples. The difference between each CT data point and the regression line (residuals) was determined and standardized, and CT were considered commutable' with PP if the standardized residual was within a range of -3 to 3. Coefficients of variation (CVs) for CT and PP for 16 analytes on 2 analyzers were compared by bootstrap analysis to determine interchangeability. ResultsMost CT analytes were within the range of patient plasma sample analytes, thus commutable. Only 2 analytes had equivalent precision for both levels of CT and both levels of PP, and 5 additional analytes had similar precision for at least one level of CT compared to at least one level of PP. ConclusionsThe QCM assessed is commutable to feline PP within the tested ranges for 2 particular analyzers. Commutability does not grant interchangeability.
引用
收藏
页码:300 / 310
页数:11
相关论文
共 37 条
  • [21] Comparisons of results between three in-house biochemistry analyzers and a commercial laboratory analyzer for feline plasma using multiple quality specifications
    Baral R.M.
    Dhand N.K.
    Krockenberger M.B.
    Govendir M.
    Comparative Clinical Pathology, 2015, 24 (5) : 1075 - 1089
  • [22] Suitability of quality control materials for prostate-specific antigen (PSA) measurement: inter-method variability of common tumor marker control materials
    Vucetic, Zivjena
    Dnistrian, Ann
    Nilsson, Olle
    Lilja, Hans G.
    Plebani, Mario
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (04) : 873 - 880
  • [23] Aggregated data from the same laboratories participating in two glucose external quality assessment schemes show that commutability and transfers of values to control materials are decisive for the biases found
    Gidske, Gro
    Sandberg, Sverre
    Fauskanger, Pernille
    Pelanti, Jonna
    Tollanes, Mette C. C.
    Solsvik, Anne E. E.
    Solvik, Una O.
    Vie, Wenche S. S.
    Stavelin, Anne
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (01) : 77 - 84
  • [24] Application of a six sigma model to evaluate the analytical performance of cerebrospinal fluid biochemical analytes and the design of quality control strategies for these assays: A single-centre study
    Liu, Qian
    Hu, Ming
    Yang, Fang
    Li, Yan
    Yang, Fumeng
    CLINICAL BIOCHEMISTRY, 2023, 114 : 73 - 78
  • [25] Atellica UAS 800 urine sediment analyzer compatibility with commercial quality control materials and urine preservative tubes
    Das, K.
    Lynch, M.
    CLINICA CHIMICA ACTA, 2019, 493 : S481 - S482
  • [26] Sperm quality and selected biochemical markers of seminal plasma at the beginning of the reproductive period of common carp, Cyprinus carpio L.
    Beata Irena Cejko
    Sławomir Krejszeff
    Sylwia Judycka
    Beata Sarosiek
    Mariola Dietrich
    Dariusz Kucharczyk
    Radosław Kajetan Kowalski
    Aquaculture International, 2014, 22 : 111 - 122
  • [27] Sperm quality and selected biochemical markers of seminal plasma at the beginning of the reproductive period of common carp, Cyprinus carpio L.
    Cejko, Beata Irena
    Krejszeff, Slawomir
    Judycka, Sylwia
    Sarosiek, Beata
    Dietrich, Mariola
    Kucharczyk, Dariusz
    Kowalski, Radoslaw Kajetan
    AQUACULTURE INTERNATIONAL, 2014, 22 (01) : 111 - 122
  • [28] Application of a six sigma model to evaluate the analytical performance of urinary biochemical analytes and design a risk-based statistical quality control strategy for these assays: A multicenter study
    Liu, Qian
    Bian, Guangrong
    Chen, Xinkuan
    Han, Jingjing
    Chen, Ying
    Wang, Menglin
    Yang, Fumeng
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (11)
  • [29] QUALITY ASSURANCE IN MEDICAL LABORATORIES - COMMERCIAL AVAILABILITY OF CONTROL MATERIALS SUITABLE FOR PRECISION TESTING AT THE MOST IMPORTANT DECISION LIMIT
    SCHELLENBERG, I
    AUSLANDER, W
    DAFONSECAWOLLHEIM, F
    SCHREIBER, G
    PTB-MITTEILUNGEN, 1992, 102 (06): : 472 - 480
  • [30] Development of genomic DNA quality control materials for genetic testing of disorders common in people of Ashkenazi Jewish descent
    Muralidharan, K.
    Wilson, J. Amos
    Butler, A. M.
    Dixon, J. B.
    Edelmann, L.
    Geller, L.
    Highsmith, W. E.
    Holtegaard, L. M.
    Kornreich, R.
    Rohlfs, E. M.
    Payeur, T. L.
    Sellers, T.
    Kalman, L. V.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 623 - 623