Absorbance-based detection of arsenic in a microfluidic system with push-and-pull pumping

被引:8
|
作者
Karakuzu, Betul [1 ]
Gulmez, Yekta [1 ]
Tekin, H. Cumhur [1 ,2 ]
机构
[1] Izmir Inst Technol, Dept Bioengn, TR-35430 Izmir, Turkey
[2] METU MEMS Ctr, TR-06520 Ankara, Turkey
关键词
Microfluidic chip; Arsenic detection; Push-and-pull pumping; Gold nanoparticles; SPECTROPHOTOMETRIC DETERMINATION; GOLD NANOPARTICLES; DRINKING-WATER; BANGLADESH; ADSORPTION; GENERATION; OXIDATION; TOXICITY; REMOVAL; METALS;
D O I
10.1016/j.mee.2021.111583
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rapid and portable analysis of arsenic (As) contamination in drinking water is very important due to its adverse health effects on humans. Available commercial detection kits have shown low sensitivity and selectivity in analysis, and also they can generate harmful by-products. Microfluidic-based approaches allow portable analysis with gold nanoparticles (AuNPs) as labels. However, they need complex surface modification steps that complicate detection protocols. Due to the lack of precise sensing and affordable solution, we focused on developing a microfluidic platform that uses a push-and-pull pumping method for sensitive detection of As. In this detection principle, a sample is introduced in the microfluidic channel modified with -SH functional groups where As can bind. Then, AuNPs are given in the channel and AuNPs bind on free -SH functional groups which are not allocated with As. Absorbance measurements are conducted to detect AuNPs absorbed on the surfaces and the resulting absorbance value is inversely proportional with As concentration. The method enables detection of As down to 2.2 mu g/L concentration levels in drinking water, which is well-below the allowed maximum As concentration of 10 mu g/L in the drinking waters by the World Health Organization (WHO). The paper reveals that multiple push-and-pull pumping of fixed volume of sample and AuNPs with a syringe pump can improve the binding efficiency in the microfluidic channel. With this technique, low amounts of sample (1 mL) and short total assay time (25 min) are sufficient to detect As.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Efficient Hybrid Push-Pull Based P2P Media Streaming System
    Keong, Chee Yik
    Hoong, Poo Kuan
    Ting, Choo-Yee
    2011 IEEE 17TH INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED SYSTEMS (ICPADS), 2011, : 735 - 740
  • [42] Design of push-pull chromophores based on the incorporation of transition metal acetylides in the main π-conjugated system
    Fillaut, Jean-Luc
    Luc, Jerome
    Sahraoui, Bouchta
    2007 ICTON MEDITERRANEAN WINTER CONFERENCE, 2007, : 3 - +
  • [43] Novel thiazoline-phenothiazine based "push-pull" molecules as fluorescent probes for volatile acids detection
    Chaudhary, Shweta
    Mukherjee, Madhubani
    Paul, Tanmoy K.
    Taraphder, Srabani
    Milton, Marilyn D.
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 397
  • [44] 8-Hydroxyquinoline based push-pull azo dye: Novel colorimetric chemosensor for anion detection
    Arslan, Omer
    Aydiner, Burcu
    Yalcin, Ergin
    Babur, Banu
    Seferoglu, Nurgul
    Seferoglu, Zeynel
    JOURNAL OF MOLECULAR STRUCTURE, 2017, 1149 : 499 - 509
  • [45] A microfluidic system for saliva-based detection of infectious diseases
    Chen, Zongyuan
    Mauk, Michael G.
    Wang, Jing
    Abrams, William R.
    Corstjens, Paul L. A. M.
    Niedbala, R. Sam
    Malamud, Daniel
    Bau, Haim H.
    ORAL-BASED DIAGNOSTICS, 2007, 1098 : 429 - 436
  • [46] Aquaculture pathogens detection based on microfluidic system with magnetic isolation
    Guo, Jianjiang
    Zhang, Rongbiao
    Yang, Ning
    Sun, Jian
    Xu, Peifeng
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2015, 46 (04): : 277 - 281
  • [47] Fluorescent dyes for moisture detection in organic solvents: Push-pull based phenothiazine aldehydes with large Stokes shifts
    Sachdeva, Tanisha
    Milton, Marilyn Daisy
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 402
  • [48] Design of detection module in laser pumping system based on virtual instrument
    Ke, Chaofan
    Peng, Xiang
    Xu, Shengchen
    Yu, Song
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2013, 42 (12): : 3315 - 3319
  • [49] Development of Reversible Acid-Base Detection Reagents Based on Push-pull Type Aminonaphthyridine and Aminoquinoline Derivatives
    Matsumoto, Shota
    Umeno, Tomohiro
    Usui, Kazuteru
    Karasawa, Satoru
    BUNSEKI KAGAKU, 2022, 71 (03) : 119 - 131
  • [50] New portable smartphone-based PDMS microfluidic kit for the simultaneous colorimetric detection of arsenic and mercury
    Motalebizadeh, Abbas
    Bagheri, Hasan
    Asiaei, Sasan
    Fekrat, Nasim
    Afkhami, Abbas
    RSC ADVANCES, 2018, 8 (48) : 27091 - 27100