Absorbance-based detection of arsenic in a microfluidic system with push-and-pull pumping

被引:8
|
作者
Karakuzu, Betul [1 ]
Gulmez, Yekta [1 ]
Tekin, H. Cumhur [1 ,2 ]
机构
[1] Izmir Inst Technol, Dept Bioengn, TR-35430 Izmir, Turkey
[2] METU MEMS Ctr, TR-06520 Ankara, Turkey
关键词
Microfluidic chip; Arsenic detection; Push-and-pull pumping; Gold nanoparticles; SPECTROPHOTOMETRIC DETERMINATION; GOLD NANOPARTICLES; DRINKING-WATER; BANGLADESH; ADSORPTION; GENERATION; OXIDATION; TOXICITY; REMOVAL; METALS;
D O I
10.1016/j.mee.2021.111583
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Rapid and portable analysis of arsenic (As) contamination in drinking water is very important due to its adverse health effects on humans. Available commercial detection kits have shown low sensitivity and selectivity in analysis, and also they can generate harmful by-products. Microfluidic-based approaches allow portable analysis with gold nanoparticles (AuNPs) as labels. However, they need complex surface modification steps that complicate detection protocols. Due to the lack of precise sensing and affordable solution, we focused on developing a microfluidic platform that uses a push-and-pull pumping method for sensitive detection of As. In this detection principle, a sample is introduced in the microfluidic channel modified with -SH functional groups where As can bind. Then, AuNPs are given in the channel and AuNPs bind on free -SH functional groups which are not allocated with As. Absorbance measurements are conducted to detect AuNPs absorbed on the surfaces and the resulting absorbance value is inversely proportional with As concentration. The method enables detection of As down to 2.2 mu g/L concentration levels in drinking water, which is well-below the allowed maximum As concentration of 10 mu g/L in the drinking waters by the World Health Organization (WHO). The paper reveals that multiple push-and-pull pumping of fixed volume of sample and AuNPs with a syringe pump can improve the binding efficiency in the microfluidic channel. With this technique, low amounts of sample (1 mL) and short total assay time (25 min) are sufficient to detect As.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Lead Time and Inventory Decisions in a Push-and-Pull System
    Xu, H.
    Zhu, S. X.
    Liu, L.
    IEEM: 2008 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1-3, 2008, : 1078 - +
  • [2] Push-and-Pull Switching: Window Switching based on Window Overlapping
    Xu, Quan
    Casiez, Gery
    CHI2010: PROCEEDINGS OF THE 28TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, VOLS 1-4, 2010, : 1335 - +
  • [3] A 3D printing assisted microfluidic absorbance-based measurement system for biological assay
    Kumar, Ankit
    Nath, Prathul
    Das, Neeladrisingha
    Chatterjee, Manisha
    Roy, Partha
    Satapathi, Soumitra
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (08)
  • [4] A hybrid microfluidic chip-based capillary electrophoresis system with UV absorbance detection
    Cao, XD
    Fang, Q
    Fang, ZL
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (07): : 1231 - 1234
  • [5] Sequential Push-Pull Pumping Mechanism for Washing and Evacuation of an Immunoassay Reaction Chamber on a Microfluidic CD Platform
    Thio, Tzer Hwai Gilbert
    Ibrahim, Fatimah
    Al-Faqheri, Wisam
    Soin, Norhayati
    Bador, Maria Kahar
    Madou, Marc
    PLOS ONE, 2015, 10 (04):
  • [6] Single-balloon push-and-pull enteroscopy system: does it work? A single-center, 3-year experience
    M. E. Riccioni
    R. Urgesi
    R. Cianci
    C. Spada
    E. C. Nista
    G. Costamagna
    Surgical Endoscopy, 2011, 25 : 3050 - 3056
  • [7] Single-balloon push-and-pull enteroscopy system: does it work? A single-center, 3-year experience
    Riccioni, M. E.
    Urgesi, R.
    Cianci, R.
    Spada, C.
    Nista, E. C.
    Costamagna, G.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (09): : 3050 - 3056
  • [8] SINGLE-BALLOON PUSH-AND-PULL ENTEROSCOPY SYSTEM: DOES IT WORK? A SINGLE-CENTRE THREE-YEAR-EXPERIENCE
    Riccioni, M.
    Cianci, R.
    Spada, C.
    Urgesi, R.
    Nista, E.
    Costamagna, G.
    DIGESTIVE AND LIVER DISEASE, 2010, 42 : S169 - S169
  • [9] Single-Balloon Push-and-Pull Enteroscopy System: Does It Work? A Single-Centre Three-Year-Experience
    Riccioni, Maria Elena
    Spada, Cristiano
    Cianci, Rosella
    Urgesi, Riccardo
    Costamagna, Guido
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB320 - AB320
  • [10] Comparative study on push and pull production system based on Anylogic
    Zheng, Ni
    Lu Xiaochun
    ECBI: 2009 INTERNATIONAL CONFERENCE ON ELECTRONIC COMMERCE AND BUSINESS INTELLIGENCE, PROCEEDINGS, 2009, : 455 - 458