How important is sample alignment in planar biaxial testing of anisotropic soft biological tissues? A finite element study

被引:7
|
作者
Fehervary, Heleen [1 ]
Vastmans, Julie [1 ]
Sloten, Jos Vander [1 ]
Famaey, Nele [1 ]
机构
[1] Katholieke Univ Leuven, Biomech Sect, Leuven, Belgium
关键词
Constitutive modeling; Planar biaxial testing; Rakes; Rail shear testing; Parameter fitting; FE simulations; Unknown sample orientation;
D O I
10.1016/j.jmbbm.2018.06.024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite element models of biomedical applications increasingly use anisotropic hyperelastic material formulations. Appropriate material parameters are essential for a reliable outcome of these simulations, which is why planar biaxial testing of soft biological tissues is gaining importance. However, much is still to be learned regarding the ideal methodology for performing this type of test and the subsequent parameter fitting procedure. This paper focuses on the effect of an unknown sample orientation or a mistake in the sample orientation in a planar biaxial test using rakes. To this end, finite element simulations were conducted with various degrees of misalignment. Variations to the test method and subsequent fitting procedures are compared and evaluated. For a perfectly aligned sample and for a slightly misaligned sample, the parameters of the Gasser-Ogden-Holzapfel model can be found to a reasonable accuracy using a planar biaxial test with rakes and a parameter fitting procedure that takes into account the boundary conditions. However, after a certain threshold of misalignment, reliable parameters can no longer be found. The level of this threshold seems to be material dependent. For a sample with unknown sample orientation, material parameters could theoretically be obtained by increasing the degrees of freedom along which test data is obtained, e.g. by adding the data of a rail shear test. However, in the situation and the material model studied here, the inhomogeneous boundary conditions of the test set-ups render it impossible to obtain the correct parameters, even when using the parameter fitting method that takes into account boundary conditions. To conclude, it is always important to carefully track the sample orientation during harvesting and preparation and to minimize the misalignment during mounting. For transversely isotropic samples with an unknown orientation, we advise against parameter fitting based on a planar biaxial test, even when combined with a rail shear test.
引用
收藏
页码:201 / 216
页数:16
相关论文
共 42 条
  • [1] Mechanical characterization of anisotropic planar biological soft tissues using finite indentation: Experimental feasibility
    Cox, Martijn A. J.
    Driessen, Niels J. B.
    Boerboorn, Ralf A.
    Bouten, Carlijn V. C.
    Baaijens, Frank P. T.
    JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 422 - 429
  • [2] A contact finite element formulation for biological soft hydrated tissues
    Donzelli, PS
    Spilker, RL
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1998, 153 (1-2) : 63 - 79
  • [3] Contact finite element formulation for biological soft hydrated tissues
    Rensselaer Polytechnic Inst, Troy, United States
    Comput Methods Appl Mech Eng, 1-2 (63-79):
  • [4] Finite element simulation of elastohydrodynamic lubrication of soft biological tissues
    Moghani, Taraneh
    Butler, James P.
    Lin, Judy Li-Wen
    Loring, Stephen H.
    COMPUTERS & STRUCTURES, 2007, 85 (11-14) : 1114 - 1120
  • [5] Mechanical characterization of anisotropic planar biological soft tissues using large indentation: A computational feasibility study
    Cox, Martijn A. J.
    Driessen, Niels J. B.
    Bouten, Carlijn V. C.
    Baaljens, Frank P. T.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (03): : 428 - 436
  • [6] Modeling of biological tissues with anisotropic hyperelastic laws - Theoretical study and finite element analysis.
    Peyraut, Francois
    Renaud, Christine
    Labed, Nadia
    Feng, Zhi-Qiang
    COMPTES RENDUS MECANIQUE, 2009, 337 (02): : 101 - 106
  • [7] Single shot quantitative polarized light imaging system for rapid planar biaxial testing of soft tissues
    Blair, Michael J.
    Quinn, Kyle P.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [8] Mixed porohyperelastic theory and finite element models for soft hydrated biological tissues
    Simon, B.R.
    Liu, J.
    Nichol, J.
    Kaufmann, M.V.
    Williams, S.K.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 741 - 742
  • [9] Planar biaxial testing of soft biological tissue using rakes: A critical analysis of protocol and fitting process
    Fehervary, Heleen
    Smoljkic, Marija
    Sloten, Jos Vander
    Famaey, Nele
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 135 - 151
  • [10] Finite element implementation of a generalized Fung-elastic constitutive model for planar soft tissues
    Sun, W
    Sacks, MS
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2005, 4 (2-3) : 190 - 199