Improvement of non-small-cell lung cancer staging by means of positron emission tomography

被引:36
|
作者
Albes, JM
Lietzenmayer, R
Schott, U
Schülen, E
Wehrmann, M
Ziemer, G
机构
[1] Univ Tubingen, Abt Thorax Herz & Gefasschirurg, Div Thorac Cardiac & Vasc Surg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Div Diagnost Radiol, Tubingen, Germany
[3] Univ Tubingen, Dept Internal Med, D-7400 Tubingen, Germany
[4] Univ Tubingen, Dept Pathol, Tubingen, Germany
[5] Univ Tubingen, Div Nucl Med, Tubingen, Germany
来源
THORACIC AND CARDIOVASCULAR SURGEON | 1999年 / 47卷 / 01期
关键词
D O I
10.1055/s-2007-1013107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Exact staging of ipsi- and contralateral mediastinal lymph-node metastases (N 1/2 vs. N3) is essential for the therapeutic strategy in non-small-cell lung cancer (NSCLC). CT and mediastinoscopy are the standards of reference for N staging. However, even with these combined measures the extent of invasion of mediastinal lymph nodes can remain vague. (18)FDG Positron Emission Tomography ((18)FDG-PET) has recently been shown to detect invaded nodes with high accuracy. The purpose of this study was to evaluate (18)FDG-PET as an aid in N staging. Methods: 27 patients with suspected NSCLC were clinically staged by means of CT, bronchoscopy, mediastinoscopy, and bone scintigraphy, Additionally,(18)FDG-PET was performed preoperatively for analysis of topography of invaded lymph nodes. CT and (18)FDG-PET were evaluated in a blinded fashion. Surgical therapy was performed with radical lymphadenectomy, CT N staging as well as PET N staging results were compared with the pathological diagnoses (pTN). Specificity, sensitivity, and accuracy of CT and PET in N staging were calculated. Results: 14 squamous-cell carcinomas, 10 adenocarcinomas, and 3 non-malignant tumors were found. In 8 patients no invasion was found (NO), in 13 patients an ipsilateral invasion (N1/2), and in 3 patients a contralateral invasion (N3). In the correct detection of N1/2 the sensitivity of CT and of PET was 0.77, the specificity of CT and of PEI was 0.79. The accuracy of CT was 0.74 and of PET 0.78, By combining CT and PET accuracy was 0.85. Conclusions: Adequate preoperative LN staging is possible with both CT and (18)FDG-PET. The accuracy, however, can be improved by a combination of CT and (18)FDG-PET.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [41] Coincidence positron emission tomography using a gamma camera for the staging of non-small cell lung cancer
    Old, SE
    Balan, KK
    Coulden, RAR
    Gilligan, D
    Parry-Jones, DR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1158 - 1158
  • [42] Gamma camera positron emission tomography (MIT) in staging non-small cell lung cancer (NSCLC).
    Old, SE
    Balan, KK
    Coulden, R
    Gilligan, D
    Parry-Jones, DR
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 246P - 247P
  • [43] False-negative rate after positron emission tomography/computer tomography scan for mediastinal staging in cI stage non-small-cell lung cancer
    Gomez-Caro, Abel
    Boada, Marc
    Cabanas, Maria
    Sanchez, Marcelo
    Arguis, Pedro
    Lomena, Francisco
    Ramirez, Josep
    Molins, Laureano
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (01) : 93 - 100
  • [44] Integrated positron emission tomography and computed tomography in preoperative lymph node staging of non-small cell lung cancer
    Xu Na
    Wang Mengzhao
    Zhu Zhaohui
    Zhang Yingqiang
    Jiao Yang
    Fang Weigang
    CHINESE MEDICAL JOURNAL, 2014, 127 (04) : 607 - 613
  • [45] Integrated positron emission tomography and computed tomography in preoperative lymph node staging of non-small cell lung cancer
    Xu Na
    Wang Mengzhao
    Zhu Zhaohui
    Zhang Yingqiang
    Jiao Yang
    Fang Weigang
    中华医学杂志(英文版), 2014, 127 (04) : 607 - 613
  • [46] Overestimation of the prognostic significance of SUV measurement by positron emission tomography for non-small-cell lung cancer - Reply
    Komaki, R
    Sasaki, R
    Allen, PK
    JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (27) : 6800 - 6800
  • [47] Role of Positron Emission Tomography in the Early Prediction of Response to Chemotherapy in Patients With Non-Small-Cell Lung Cancer
    Skoura, Evangelia
    Datseris, Ioannis E.
    Platis, Ioannis
    Oikonomopoulos, Georgios
    Syrigos, Konstantinos N.
    CLINICAL LUNG CANCER, 2012, 13 (03) : 181 - 187
  • [48] Impact of FDG-labelled positron emission tomography imaging on the management of non-small-cell lung cancer
    Salminen, E
    Mac Manus, M
    ANNALS OF MEDICINE, 2001, 33 (06) : 404 - 409
  • [49] Positron emission tomography in the management of non-small cell lung cancer
    Vansteenkiste, JF
    Stroobants, SG
    HEMATOLOGY-ONCOLOGY CLINICS OF NORTH AMERICA, 2004, 18 (01) : 269 - +
  • [50] Positron emission tomography (PET) of non-small cell lung cancer
    Haberkorn, U
    LUNG CANCER, 2001, 34 : S115 - S121