Prediction of boron concentrations in blood from patients on boron neutron capture therapy

被引:0
|
作者
Shibata, Y
Matsumura, A [1 ]
Yamamoto, T
Akutsu, H
Yasuda, S
Nakai, K
Nose, T
Yamamoto, K
Kumada, H
Hori, N
Ohtake, S
机构
[1] Univ Tsukuba, Dept Neurosurg, Tsukuba, Ibaraki 3058575, Japan
[2] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
关键词
boron neutron capture therapy; BSH; glioblastoma; prompt gamma ray analysis; radiation therapy;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In boron neutron capture therapy, blood boron concentration is the key factor to calculate radiation dose, however, blood sampling is difficult during neutron irradiation. Materials and Methods: The prediction of blood boron concentrations for BNCT treatment planning has been prospectively investigated using patient data obtained at first craniotomy after the infusion of a low dose of sodium undecahydroclosododecaborate. Results: The boron biodistribution data showed a biexponential pharmacokinetic profile. If the final boron concentration at 6 or 9 hours after the end of the infusion is within the 95% confidence interval of the prediction, direct prediction from biexponential fit will reduce the error of blood boron concentrations during irradiation to around 6%. Conclusion: Actual boron concentrations during BNCT were reasonably and accurately predictable from the test data.
引用
收藏
页码:5231 / 5235
页数:5
相关论文
共 50 条
  • [31] Boron analysis and boron imaging in biological materials for Boron Neutron Capture Therapy (BNCT)
    Wittig, Andrea
    Michel, Jean
    Moss, Raymond L.
    Stecher-Rasmussen, Finn
    Arlinghaus, Heinrich F.
    Bendel, Peter
    Mauri, Pier Luigi
    Altieri, Saverio
    Hilger, Ralf
    Salvadori, Piero A.
    Menichetti, Luca
    Zamenhof, Robert
    Sauerwein, Wolfgang A. G.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 68 (01) : 66 - 90
  • [32] The accelerator neutron source for boron neutron capture therapy
    Kasatov, D.
    Koshkarev, A.
    Kuznetsov, A.
    Makarov, A.
    Ostreinov, Yu
    Shchudlo, I.
    Sorokin, I.
    Sycheva, T.
    Taskaev, S.
    Zaidi, L.
    18TH INTERNATIONAL CONFERENCE PHYSICA.SPB, 2016, 769
  • [33] Fast Neutron Beams for Boron Neutron Capture Therapy?
    Wolber, Gerd
    Zeitschrift fur Medizinische Physik, 2004, 14 (01): : 55 - 63
  • [34] Capillary neutron optics for boron neutron capture therapy
    Xiao, QF
    Sharov, VA
    Gibson, DM
    Chen, H
    Mildner, DFR
    Downing, RG
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 399 - 406
  • [35] A Compact Neutron Source for Boron Neutron Capture Therapy
    S. V. Golubev
    I. V. Izotov
    S. V. Razin
    A. V. Sidorov
    V. A. Skalyga
    Radiophysics and Quantum Electronics, 2017, 59 : 682 - 689
  • [36] A COMPACT NEUTRON SOURCE FOR BORON NEUTRON CAPTURE THERAPY
    Golubev, S. V.
    Izotov, I. V.
    Razin, S. V.
    Sidorov, A. V.
    Skalyga, V. A.
    RADIOPHYSICS AND QUANTUM ELECTRONICS, 2017, 59 (8-9) : 682 - 689
  • [37] Design of a neutron target for boron neutron capture therapy
    Wang J.
    Kong H.
    Li D.
    He Jishu/Nuclear Techniques, 2024, 47 (04):
  • [38] Utilizing neutron generators in boron neutron capture therapy
    Metwally, Walid A.
    Adel, Yumna
    Dalah, Entesar Z.
    Al-Omari, Husam
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [39] Imaging of boron in tissue at the cellular level for boron neutron capture therapy
    Arlinghaus, HF
    Spaar, MT
    Switzer, RC
    Kabalka, GW
    ANALYTICAL CHEMISTRY, 1997, 69 (16) : 3169 - 3176
  • [40] Boron neutron capture therapy for glioblastoma: improvement of boron biodistribution by hyaluronidase
    Haselsberger, K
    Radner, H
    Pendl, C
    CANCER LETTERS, 1998, 131 (01) : 109 - 111