High pressure CO2 reduces the wet heat resistance of Bacillus subtilis spores by perturbing the inner membrane

被引:13
|
作者
Rao, Lei [1 ,2 ,3 ]
Wang, Yongtao [2 ,3 ]
Chen, Fang [2 ,3 ]
Hu, Xiaosong [1 ,2 ,3 ]
Liao, Xiaojun [1 ,2 ,3 ]
Zhao, Liang [2 ,3 ,4 ]
机构
[1] China Agr Univ, Coll Food Sci & Nutr Engn, Beijing Adv Innovat Ctr Food Nutr & Human Hlth, Beijing 100083, Peoples R China
[2] Natl Engn Res Ctr Fruit & Vegetable Proc, Beijing Key Lab Food Nonthermal Proc, Beijing 100083, Peoples R China
[3] Minist Agr, Key Lab Fruit & Vegetable Proc, Beijing 100083, Peoples R China
[4] China Agr Univ, Xinghua Ind Res Ctr Food Sci & Human Hlth, Xinghua 225700, Jiangsu, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Bacillus subtilis; Spores; High pressure CO2; Heat resistance; CARBON-DIOXIDE PASTEURIZATION; THERMAL-STABILITY; BACTERIAL-SPORES; SINGLE SPORES; INACTIVATION; GERMINATION; ACTIVATION; MECHANISM; FOODS; STERILIZATION;
D O I
10.1016/j.ifset.2020.102291
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Spores of wild-type Bacillus subtilis PS533 were treated by wet heat at 75 degrees C for 30 min, and high pressure CO2 (HPCD) at 6.5 MPa and 30 degrees C or 75 degrees C for 30 min. The spores were analyzed for wet heat resistance (85 degrees C, 90 degrees C, 95 degrees C) and typical germination events including DPA release and cortex hydrolysis, inner membrane permeability, and germination triggered by nutrient (L-valine and AGFK) or non-nutrient (dodecylamine and high pressure at 150 MPa or 550 MPa) germinants. The results showed that (i) HPCD-treated spores exhibited reduced wet heat resistance compared to the untreated or wet heat-treated spores; (ii) HPCD-treated spores did not undergo typical germination events such as DPA release or cortex hydrolysis compared to normally germinated spores; (iii) HPCD-treated spores released more metal ions and exhibited decreased ability to maintain DPA, indicating that the permeability of inner membrane of HPCD-treated spores was increased; (iv) HPCD-treated spores exhibited reduced germination rate when triggered by L-valine or 150 MPa, but increased germination rate when triggered by dodecylamine or 550 MPa, suggesting that the fluidity of the inner membrane of HPCD-treated spores might be increased. These results indicated that HPCD could reduce the wet heat resistance of spores, and this resistance decrease was probably due to the modification of the inner membrane caused by HPCD. Industrial relevance: The extremely high wet heat resistance of spores makes them a significant problem in the thermal processing of foods. Thus, it of great interest to develop a process to reduce the wet heat resistance of spores. In this work, we found that HPCD can significantly reduce the wet heat resistance of B. subtilis spores, and this was achieved by perturbing the inner membrane of spores. These results can improve our understanding of the inactivation mechanism of spores by HPCD, and also provide an alternative approach for spore inactivation in foods.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Mechanism of Bacillus subtilis spore inactivation by and resistance to supercritical CO2 plus peracetic acid
    Setlow, B.
    Korza, G.
    Blatt, K. M. S.
    Fey, J. P.
    Setlow, P.
    JOURNAL OF APPLIED MICROBIOLOGY, 2016, 120 (01) : 57 - 69
  • [22] Zeolite membrane for CO2 removal:: Operating at high pressure
    Sebastian, Victor
    Kumakiri, Izumi
    Bredesen, Rune
    Menendez, Miguel
    JOURNAL OF MEMBRANE SCIENCE, 2007, 292 (1-2) : 92 - 97
  • [23] Zeolite membrane for CO2 removal:: operating at high pressure
    Sebastian, Victor
    Kumakiri, Izumi
    Bredesen, Rune
    Menendez, Miguel
    DESALINATION, 2006, 199 (1-3) : 464 - 465
  • [24] High-level iron mitigates fusaricidin-induced membrane damage and reduces membrane fluidity leading to enhanced drug resistance in Bacillus subtilis
    Yu, Wen-Bang
    Ye, Bang-Ce
    JOURNAL OF BASIC MICROBIOLOGY, 2016, 56 (05) : 502 - 509
  • [25] High pressure/temperature membrane contactors for CO2 capture processes
    Volkov, A.
    Vasilevsky, V.
    Lysenko, A.
    Runstraat, A.
    Matson, S.
    Khotimskiy, V.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 332 - 334
  • [26] Inactivation of bacteria and spores by pulse electric field and high pressure CO2 at low temperature
    Spilimbergo, S
    Dehghani, F
    Bertucco, A
    Foster, NR
    BIOTECHNOLOGY AND BIOENGINEERING, 2003, 82 (01) : 118 - 125
  • [27] Hydrolases in supercritical CO2 and their use in a high-pressure membrane reactor
    Ž. Knez
    M. Habulin
    M. Primožič
    Bioprocess and Biosystems Engineering, 2003, 25 : 279 - 284
  • [28] Ionic Liquid Embedded in Polymeric Membrane for High Pressure CO2 Separation
    Mohshim, Dzeti Farhah
    Mukhtar, Hilmi
    Man, Zakaria
    PRES15: PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2015, 45 : 1423 - 1428
  • [29] Carbon membrane gas separation of binary CO2 mixtures at high pressure
    Kruse, N.
    Schiesser, Y.
    Kaemnitz, S.
    Richter, H.
    Voigt, I.
    Braun, G.
    Repke, J. U.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 164 : 132 - 137
  • [30] CO2 desorption using high-pressure bipolar membrane electrodialysis
    Eisaman, Matthew D.
    Alvarado, Luis
    Larner, Daniel
    Wang, Peng
    Littau, Karl A.
    ENERGY & ENVIRONMENTAL SCIENCE, 2011, 4 (10) : 4031 - 4037