摘要
Medium voltage (MV) synchronous machines (SMs) are expected to ride through adjustable speed drive (ASD) faults, excitation faults, system faults/disturbances and supply transfers. Models suitable for direct-on-line and ASD ride-through simulations are discussed. Case studies, simulation and test results are presented for an 11 kV ASD for 17 MW SMs and for a 55 MW SM. It is shown that line fed and ASD fed SMs can survive system faults and voltage dips without additional compensation or energy storage. ASD fed SMs have far better survivability characteristics than line fed SMs. SMs can ride through ASD faults associated with fault tolerant schemes when correctly configured. Boundary supply transfer angles are determined to eliminate unacceptable transients. Aspects requiring special attention for SMs in addition to the induction motor (IM) ride-trough requirements are high-lighted. Recommendations are provided to improve availability of ASD started/driven SMs.
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 50 条
  • [41] Low-Voltage Ride-Through Simulation for Microgrid Systems
    Foruzan, Elham
    Algrain, Marcelo C.
    Asgarpoor, Sohrab
    2017 IEEE INTERNATIONAL CONFERENCE ON ELECTRO INFORMATION TECHNOLOGY (EIT), 2017, : 260 - 264
  • [42] Dual 3-Phase Bridge Multilevel Inverters for AC Drives with Voltage Sag Ride-through Capability
    Pires, Vitor Fernao
    Monteiro, Joaquim
    Silva, Jose Fernando
    ENERGIES, 2019, 12 (12)
  • [43] Ride-through alternatives for adjustable-speed drives - Computational analysis
    Belchior, FN
    Oliveira, JC
    Leao, PCA
    Souto, OCN
    2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, : 1032 - 1036
  • [44] Microgrid protection considering low voltage ride-through of IIDG
    Han H.
    Mu L.
    Zhang F.
    Guo W.
    Mu, Longhua (lhmu@tongji.edu.cn), 1600, Chinese Society for Electrical Engineering (37): : 110 - 119
  • [45] Study of Low Voltage Ride-through Capability in DC Distribution
    Jin Y.
    Xu X.
    Dianwang Jishu/Power System Technology, 2023, 47 (12): : 5108 - 5119
  • [46] A novel combined approach to voltage sag ride-through and current waveform improvement for adjustable-speed drives
    Xu, JH
    Al-Haddad, K
    Sicard, P
    Rajagopalan, V
    PESC 2001: 32ND ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2001, : 1315 - 1320
  • [47] Low Voltage Ride-Through of a Synchronous Reluctance Generator Based Variable Speed Wind Energy Conversion System
    Basak, Rupam
    Bhuvaneswari, G.
    2018 IEEMA ENGINEER INFINITE CONFERENCE (ETECHNXT), 2018,
  • [48] Fault Ride-Through Capability of Voltage-Controlled Inverters
    Piya, Prasanna
    Ebrahimi, Mohammad
    Karimi-Ghartemani, Masoud
    Khajehoddin, Sayed Ali
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (10) : 7933 - 7943
  • [49] A Virtual Synchronous Generator Low-Voltage Ride-Through Control Strategy Considering Complex Grid Faults
    Yin, Jun
    Chen, Ziang
    Qian, Weichen
    Zhou, Shengyu
    APPLIED SCIENCES-BASEL, 2025, 15 (04):
  • [50] Fault Ride-Through Control of Medium-Voltage Converters With LCL Filter in Distributed Generation Systems
    Meyer, Robert
    Zlotnik, Alexander
    Mertens, Axel
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (05) : 3448 - 3456