A Novel L-Lactate Sensor Based on Enzyme Electrode Modified with ZnO Nanoparticles and Multiwall Carbon Nanotubes

被引:0
|
作者
Wang, Y. T. [1 ]
Bao, Y. J. [1 ]
Lou, L. [1 ]
Li, J. J. [1 ]
Du, W. J. [1 ]
Zhu, Z. Q. [1 ]
Peng, H. [1 ]
Zhu, J. Z. [1 ]
机构
[1] E China Normal Univ, Inst Adv Interdisciplinary Res, Shanghai 200062, Peoples R China
来源
2010 IEEE SENSORS | 2010年
关键词
GLUCOSE-OXIDASE; AMPEROMETRIC BIOSENSOR; IMMOBILIZATION; NANORODS; MATRIX;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A highly sensitive and stable L-Lactate sensor based on the synergic action of multi-wall carbon nanotube (MWCNTs) and ZnO nanoparticles has been developed. The unique sandwich-like layer structure (PDDA/LOD/ZnO/MWCNTs) provides a favorable microenvironment to keep the bioactivity of LOD and prevent enzyme molecule leakage. Therefore, the proposed L-Lactate biosensor exhibited good analytical performances including high sensitivity and selectivity with satisfactory stability to amperometric determination of L-Lactate. The results indicated that the proposed PDDA/LOD/ZnO/MWCNTs film was an attractive matrix for the immobilization of LOD enzymes to fabricate biosensors.
引用
收藏
页码:33 / 37
页数:5
相关论文
共 50 条
  • [41] Dataset on fabrication of an improved L-lactate biosensor based on lactate oxidase/cMWCNT/CuNPs/PANI modified PG electrode
    Dagar, Kusum
    Pundir, C. S.
    DATA IN BRIEF, 2018, 17 : 1163 - 1167
  • [42] Simultaneous determination of dihydroxybenzene isomers based on thionine functionalized multiwall carbon nanotubes modified electrode
    Liu, Yuanxiang
    Wang, Weiwei
    Wei, Huan
    Li, Jiawei
    Lu, Xiaoquan
    Liu, Xiuhui
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (05) : 667 - 674
  • [43] Simultaneous determination of dihydroxybenzene isomers based on thionine functionalized multiwall carbon nanotubes modified electrode
    Yuanxiang Liu
    Weiwei Wang
    Huan Wei
    Jiawei Li
    Xiaoquan Lu
    Xiuhui Liu
    Journal of Applied Electrochemistry, 2014, 44 : 667 - 674
  • [44] Disposable L-lactate biosensor based on a screen-printed carbon electrode enhanced by graphene
    Tu, Dandan
    He, Yu
    Rong, Yuanzhen
    Wang, You
    Li, Guang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (04)
  • [45] Modified Au nanoparticles-imprinted sol-gel, multiwall carbon nanotubes pencil graphite electrode used as a sensor for ranitidine determination
    Rezaei, B.
    Lotfi-Forushani, H.
    Ensafi, A. A.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 : 113 - 119
  • [46] A novel dopamine electrochemical sensor based on multiwall carbon nanotubes-cetyltrimethylammonium bromide/nitrogen doped ultra-thin carbon nanosheets composites modified glassy carbon electrode
    Zhang, Li
    Wu, Feng
    Zou, Qiongyu
    Fei, Junjie
    Xie, Yixi
    MICROCHEMICAL JOURNAL, 2023, 195
  • [47] Modified Au Nanoparticles/Imprinted Sol-Gel/Multiwall Carbon Nanotubes Pencil Graphite Electrode as a Selective Electrochemical Sensor for Papaverine Determination
    Rezaei, Behzad
    Esfahani, Melody Hamedian
    Ensafi, Ali A.
    IEEE SENSORS JOURNAL, 2016, 16 (19) : 7037 - 7044
  • [48] Electrochemical determination of Tannins using multiwall carbon nanotubes modified glassy carbon electrode
    Lü, SF
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2004, 40 (07) : 750 - 754
  • [49] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [50] Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    Salimi, A
    Hallaj, R
    Khayatian, GR
    ELECTROANALYSIS, 2005, 17 (10) : 873 - 879