Evaluation of intra-aneurysmal hemodynamics after flow diverter placement in a patient-specific aneurysm model

被引:9
|
作者
Balasso, Andrea [1 ]
Bauer, Jan S. [1 ]
Liebig, Thomas [2 ]
Dorn, Franziska [2 ]
Zimmer, Claus [1 ]
Liepsch, Dieter [3 ]
Prothmann, Sascha [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-80290 Munich, Germany
[2] Univ Cologne, Dept Neuroradiol, D-50931 Cologne, Germany
[3] Munich Univ Appl Sci, Munich, Germany
关键词
Stent; flow diversion; endovascular; non-Newtonian fluid; laser Doppler anemometry; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; SACCULAR ANEURYSMS; STENT; ARTERY; RECONSTRUCTION; THROMBOSIS; RUPTURE; STRESS;
D O I
10.3233/BIR-14019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
BACKGROUND: The growth and rupture of cerebral aneurysms is intrinsically related to the hemodynamics prevailing in the diseased area. Therefore, a better understanding of intra-aneurysmal hemodynamics is essential for developing effective treatment methods. OBJECTIVE: The intention of this study was to evaluate the intra-aneurysmal flow and flow reduction induced by flow diverters in a true-to-scale elastic aneurysm model, obtained from real patient data. METHODS: Based on the computed tomography angiography (CTA) data of a fusiform aneurysm of a 34 year old patient, an elastic silicon rubber model of the aneurysm was produced. A physiologic pulsatile flow was created with a circulatory experimental set-up, and a non-Newtonian perfusion fluid was used as a substitute for human blood. Hemodynamics were measured by LDA before and after flow diverter implantation. RESULTS: Implantation of a flow diverter device resulted in a reduction of intra-aneurysmal maximum flow velocities of 97.8% at the inflow zone, 89.1% in the dome and 89.3% at the outflow zone, when compared to the native model. A significant reduction of 94% in the mean intra-aneurysmal velocity was found. CONCLUSIONS: This promising methodology can optimize patient treatment and will correlate with computational simulations to evaluate their reliability.
引用
收藏
页码:341 / 354
页数:14
相关论文
共 50 条
  • [21] The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry
    Franziska Dorn
    Franz Niedermeyer
    Andrea Balasso
    Dieter Liepsch
    Thomas Liebig
    Neuroradiology, 2011, 53 : 267 - 272
  • [22] CFD to Quantify Idealized Intra-Aneurysmal Blood Flow in Response to Regular and Flow Diverter Stent Treatment
    Sanches, Augusto Fava
    Shit, Suprosanna
    Oezpeynirci, Yigit
    Liebig, Thomas
    FLUIDS, 2022, 7 (08)
  • [23] Critical Influence of Framing Coil Orientation on Intra-Aneurysmal and Neck Region Hemodynamics in a Sidewall Aneurysm Model COMMENTS
    Nozaki, Kazuhiko
    Baimeedi, Praveen R.
    Ture, Ugur
    Murayama, Yuichi
    NEUROSURGERY, 2010, 67 (06) : 1702 - 1702
  • [24] Computational Hemodynamic Analysis Of Intra-Aneurysmal Effects Due To Flow Diverter Stent Deployment Conformation
    Dinh Huy
    Chien Aichi
    STROKE, 2022, 53
  • [25] Intra-aneurysmal thrombus modification after flow-diversion
    Zanaty, Mario
    Jabbour, Pascal M.
    Sader, Roula Bou
    Chalouhi, Nohra
    Tjoumakaris, Stavropoula
    Rosenwasser, Robert H.
    Gonzalez, L. Fernando
    JOURNAL OF CLINICAL NEUROSCIENCE, 2015, 22 (01) : 105 - 110
  • [26] Effects of Variations of Flow and Heart Rate on Intra-Aneurysmal Hemodynamics in a Ruptured Internal Carotid Artery Aneurysm During Exercise
    Sarrami-Foroushani, Ali
    Esfahany, Mohsen Nasr
    Rad, Hamidreza Saligheh
    Firouznia, Kavous
    Shakiba, Madjid
    Ghanaati, Hossein
    IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (01)
  • [27] Evaluation of intra-aneurysmal blood flow: Investigation of the flow in experimental aneurysms
    Asakura, F
    Tenjin, H
    Matsumoto, K
    Ueda, S
    INTERVENTIONAL NEURORADIOLOGY, 1998, 4 : 77 - 80
  • [28] Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment
    Kulcsar, Z.
    Houdart, E.
    Bonafe, A.
    Parker, G.
    Millar, J.
    Goddard, A. J. P.
    Renowden, S.
    Gal, G.
    Turowski, B.
    Mitchell, K.
    Gray, F.
    Rodriguez, M.
    van den Berg, R.
    Gruber, A.
    Desal, H.
    Wanke, I.
    Ruefenacht, D. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 20 - 25
  • [29] Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage
    Froelich, Andreas Maximilian
    Nawka, Marie Teresa
    Ernst, Marielle
    Frischmuth, Isabell
    Fiehler, Jens
    Buhk, Jan-Hendrik
    PLOS ONE, 2018, 13 (02):
  • [30] An experimental model for the acute and chronic evaluation of intra-aneurysmal pressure
    Faries, PL
    Sanchez, LA
    Marin, ML
    Parsons, RE
    Lyon, RT
    Oliveri, S
    Veith, FJ
    JOURNAL OF ENDOVASCULAR SURGERY, 1997, 4 (03): : 290 - 297