A comprehensive exergy-based evaluation on cascade absorption-compression refrigeration system for low temperature applications - exergy, exergoeconomic, and exergoenvironmental assessments

被引:120
|
作者
Mousavi, Seyed Ali [1 ]
Mehrpooya, Mehdi [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
Cascade utilization; Low-temperature applications; Hybrid refrigeration; Exergy analysis; Exergoeconomic analysis; Exergoenvironmental analysis; WATER PRODUCTION PROCESS; CO2 POWER CYCLE; MULTIOBJECTIVE OPTIMIZATION; ENVIRONMENTAL-ANALYSES; ENERGY; HYDROGEN; HEAT; STEAM; WASTE; PLANT;
D O I
10.1016/j.jclepro.2019.119005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main target of present work is to assess a new cascade absorption-compression refrigeration system from the exergy, exergoeconomic, and exergoenvironmental standpoints. The combined system is simulated by Aspen HYSYS V10, and Matlab software. This hybrid system is able to supply a cooling duty of 60.65 kW with a coefficient of performance of 0.226. Also, the evaporation temperature of this system is calculated to be -54.62 degrees C. In order to analysis the energy quality and performance of this process, an exergy assessment is conducted. Based on the gained outcomes of exergy evaluation, the total exergy efficiency of process is computed to be 69%. As well as, the overall exergy destruction rate is obtained by 83.4 kW, and the greatest value of irreversibility is found to be in the rectifier (16.05 kW). In continue, to evaluate the process economically, the exergoeconomic evaluation is carried out. It was found that the rectifier has the largest amount of investment cost rate (2.817 $/h). As well as, the highest values of relative cost difference (r) and exergoeconomic factor (f) are related to the compressor and gas heat exchanger, respectively. The environmental impacts of hybrid system are determined by combining life cycle assessment and exergy evaluation (exergoenvironmental method). According to the achieved outcomes, it can be noticed that rectifier and low - pressure pump have the largest and least values of environmental impact. At the final stage of this research, to evaluate the interaction between environmental, technical, and economical aspects of process, the 3D parametric assessment is conducted on devices of the auto - cascade refrigeration system. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Energy and exergy analysis of proposed compression-absorption refrigeration assisted by a heat-driven turbine at low evaporating temperature
    Chen, Wei
    Li, Zoulu
    Sun, Qiang
    Zhang, Bin
    ENERGY CONVERSION AND MANAGEMENT, 2019, 191 : 55 - 70
  • [32] Investigation of a Hybridized Cascade Trigeneration Cycle Combined with a District Heating and Air Conditioning System Using Vapour Absorption Refrigeration Cooling: Energy and Exergy Assessments
    Agberegha, Larry Orobome
    Aigba, Peter Alenoghena
    Nwigbo, Solomon Chuka
    Onoroh, Francis
    Samuel, Olusegun David
    Bako, Tanko
    Der, Oguzhan
    Ercetin, Ali
    Sener, Ramazan
    ENERGIES, 2024, 17 (06)
  • [33] Energy, Exergy, Economic, Exergoeconomic, and Exergoenvironmental (5E) Analyses and Optimization of a Novel Three-Stage Cascade System Based on Liquefied Natural Gas Cold Energy
    Wu, Jingjing
    Shang, Liyan
    Pan, Zhen
    Zhou, Li
    ENERGY TECHNOLOGY, 2022, 10 (07)
  • [34] An innovative hybrid structure of solar PV-driven air separation unit, molten carbonate fuel cell, and absorption-compression refrigeration system (Process development and exergy analysis)
    Ghorbani, Bahram
    Rahnavard, Zahra
    Ahmadi, Mohammad Hossein
    Jouybari, Alireza Khatami
    ENERGY REPORTS, 2021, 7 : 8960 - 8972
  • [35] Exergy and economic analyses of an innovative integrated system for cogeneration of treated biogas and liquid carbon dioxide using absorption-compression refrigeration system and ORC/Kalina power cycles through geothermal energy
    Ebrahimi, Armin
    Ghorbani, Bahram
    Ziabasharhagh, Masoud
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 158 : 257 - 281
  • [36] Energy- and exergy-based optimal designs of a low-temperature industrial waste heat recovery system in district heating
    Fito, Jaume
    Hodencq, Sacha
    Ramousse, Julien
    Wurtz, Frederic
    Stutz, Benoit
    Debray, Francois
    Vincent, Benjamin
    ENERGY CONVERSION AND MANAGEMENT, 2020, 211
  • [37] Energy and exergy performance evaluation of a three-stage auto-cascade refrigeration system using low-GWP alternative refrigerants
    Qin, Yanbin
    Li, Nanxi
    Zhang, Hua
    Liu, Baolin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 126 : 66 - 75
  • [38] Thermodynamic and exergy evaluation of an innovative hydrogen liquefaction structure based on ejector-compression refrigeration unit, cascade multi-component refrigerant system, and Kalina power plant
    Jouybari, Alireza Khatami
    Ilinca, Adrian
    Ghorbani, Bahram
    Rooholamini, Sajedeh
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (62) : 26369 - 26393
  • [39] Exergy destruction characteristics of a transcritical carbon dioxide two-stage compression/ejector refrigeration system for low-temperature cold storage
    Yang, Dazhang
    Li, Yang
    Xie, Jing
    Wang, Jinfeng
    ENERGY REPORTS, 2022, 8 : 8546 - 8562
  • [40] Investigation of an efficient and environmentally-friendly CCHP system based on CAES, ORC and compression-absorption refrigeration cycle: Energy and exergy analysis
    Razmi, Amirreza
    Soltani, M.
    Torabi, M.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 195 (1199-1211) : 1199 - 1211