Evaluation of hydrogen peroxide in rainwater in downtown Sao Paulo

被引:0
|
作者
Santos, M. A. [1 ]
Pedrotti, J. J. [1 ]
Fornaro, A. [1 ]
机构
[1] Univ Presbiteriana Mackenzie, Dept Quim, Rua Consolacao 896, BR-01302907 Sao Paulo, Brazil
来源
基金
巴西圣保罗研究基金会;
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The concentration of hydrogen peroxide (H2O2) in rainwater samples collected between April 2003 and April 2004 in downtown Sao Paulo were determined. The concentrations of H2O2 ranged from 2.29 to 48.6 mu mol L-1, with an average value (n = 70) of 13.1 (+/- 11.3) mu mol L-1. The higher concentrations were observed in spring and summer. The volume-weighted mean (VWM) of the free H+ was 6.5 mu mol L-1, corresponding to a pH of 5.2. The analysisOf SO42-, NO3-, and HCOO-, in the same set of samples, showed an average concentration of 11.7 (+/- 10.9), 20.0 ( +/- 18.0), and 6.18 ( +/- 12.4) mu mol L-1, respectively. The HCOO- concentrations showed correlation (r = 0.43) with H2O2,which can indicate reactions in aqueous phase where these two species are formed.
引用
收藏
页码:119 / +
页数:3
相关论文
共 50 条
  • [21] Economic impacts of Sao Paulo downtown rehabilitation: a simplified approach with micro-foundations
    Biderman, Ciro
    Hermann, Bruno
    Cotelo, Fernando
    REGIONAL STUDIES, 2017, 51 (09) : 1362 - 1373
  • [22] LOW INCOME HOUSING, SQUATTING AND PROPERTY IN DOWNTOWN SAO PAULO: THE TRAJECTORY OF A FAMILY AND A BUILDING
    Cymbalista, Renato
    REVISTA DE DIREITO DA CIDADE-CITY LAW, 2020, 12 (04): : 508 - 527
  • [23] Mortality in Sao Paulo, Sao Paulo, Brazil
    不详
    PUBLIC HEALTH REPORTS, 1904, 19 (47) : 2431 - 2431
  • [24] Determination of hydrogen peroxide in rainwater in a miniaturised analytical system
    Marle, L
    Greenway, GM
    ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) : 20 - 25
  • [25] Chemiluminescence flow sensor for the monitoring of hydrogen peroxide in rainwater
    Qin, W
    Zhang, ZJ
    Chen, HH
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1997, 66 (03) : 191 - 200
  • [26] THE CONTRIBUTION OF RAINWATER TO VARIABILITY IN SURFACE HYDROGEN-PEROXIDE
    COOPER, WJ
    SALTZMAN, ES
    ZIKA, RG
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1987, 92 (C3): : 2970 - 2980
  • [27] A postoccupancy evaluation of workplaces in Sao Paulo, Brazil
    Ornstein, SW
    ENVIRONMENT AND BEHAVIOR, 1999, 31 (04) : 435 - 462
  • [28] An international evaluation of DARE in Sao Paulo, Brazil
    Shamblen, Stephen R.
    Courser, Matthew W.
    Abadi, Melissa H.
    Johnson, Knowlton W.
    Young, Linda
    Browne, Thomas J.
    DRUGS-EDUCATION PREVENTION AND POLICY, 2014, 21 (02) : 110 - 119
  • [29] Urban mobility infrastructures as public spaces: The uses of Se subway station in downtown Sao Paulo
    Martin, Cristiana
    URBAN STUDIES, 2023, 60 (15) : 3110 - 3125
  • [30] ALFAFA EVALUATION IN REGION OF SAO CARLOS, SAO PAULO STATE, BRAZIL
    Rassini, Joaquim Bartolomeu
    Ferreira, Reinaldo de Paula
    Moreira, Adonis
    Vilela, Duarte
    BOLETIM DE INDUSTRIA ANIMAL, 2007, 64 (04): : 289 - 293