Experimental and numerical study on net section resistance of high strength steel staggered bolted connections

被引:13
|
作者
Lin, Xue-Mei [1 ,2 ]
Yam, Michael C. H. [1 ,2 ]
Chung, Kwok-Fai [2 ,3 ]
Ke, Ke [4 ]
He, Qun [1 ,2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Chinese Natl Engn Res Ctr Steel Construct, Hong Kong Branch, Hong Kong, Peoples R China
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Chongqing Univ, Sch Civil Engn, Key Lab New Technol Construct Cities Mt Area, Chongqing, Peoples R China
关键词
High strength steel; Staggered bolted connections; Net section resistance; Reliability analysis; Finite element analysis; Experimental investigation; FRACTURE-BEHAVIOR; CALIBRATION; STRESS; DESIGN; MODEL;
D O I
10.1016/j.engstruct.2021.113111
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the structural behaviour and ultimate strength of high strength steel (HSS) staggered bolted connections under tension. A total of 33 HSS (Q690 and Q960) and 15 Q345 staggered bolted connection specimens were tested. All specimens failed in net section fracture through the staggered path. The predicted net section resistance based on the s2/4g rule was achieved by most of the HSS specimens. For the specimens with a small bolt pitch to gauge (s/g) ratio, the connection efficiency (i.e., the ratio between the test ultimate load and the calculated net section resistance) exceeded 1.0 and decreased gradually with an increasing s/g ratio. Compared with the mild steel (MS) specimens, in general the HSS specimens have lower connection efficiency and overall deformation capability. Subsequently, the structural behaviour of the test specimens was investigated using finite element (FE) analysis to further interpret the test observations. The results of the test and the FE analysis indicated that for the HSS specimens, effective stress redistribution along the staggered net section was observed although the ductility and the ratio of tensile strength to yield strength (fu/fy) of HSS material are relatively lower than those of the MS material. In addition, it was also observed that the biaxial state of stress that existed in the plate area between the staggered bolt holes was influenced by the s/g ratio, which would affect the ultimate strength of the test specimens. A reliability analysis of the HSS specimens test results was carried out to re-evaluate the partial factor adopted in the design equation of the net section resistance of HSS (up to S700) in EN 1993-1-12. The analysis results of the limited test data showed that the net section resistance of HSS staggered bolted connections was predicted conservatively by the current design equation with a partial factor of 1.25.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Finite element analysis and experimental study on high strength bolted friction grip connections in steel bridges
    Huang, Yong-hui
    Wang, Rong-hui
    Zou, Jin-hua
    Gan, Quan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (06) : 803 - 815
  • [22] Experimental study on bearing capacity of Q460 high-strength steel bolted connections
    Q460高强钢螺栓连接承载性能试验研究
    2018, Chinese Society of Civil Engineering (51):
  • [23] Experimental study on static behaviour of high-strength weathering steel bolted bearing type connections
    Nie S.
    Li J.
    Sun X.
    Cheng Z.
    Yang B.
    Wang H.
    Chen Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (06): : 107 - 118
  • [24] Experimental and numerical study on high-strength steel flange-welded web-bolted connections under fire conditions
    Qiang, Xuhong
    Shu, Yue
    Jiang, Xu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 192
  • [25] Testing and design of stainless steel staggered bolted connections
    dos Santos, Joao de J.
    Liang, Yating
    Zhao, Ou
    de Andrade, Sebastiao A. L.
    de Lima, Luciano R. O.
    Gardner, Leroy
    Vellasco, Pedro C. G. da S.
    ENGINEERING STRUCTURES, 2021, 231
  • [26] Investigation of block shear strength of high strength steel bolted connections
    Lin, Xue-Mei
    Yam, Michael C. H.
    Ke, Ke
    He, Qun
    Chung, Kwok-Fai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [27] Analytical Study on Yield Resistance for Staggered Arranged High Strength Bolted Frictional Joints
    Qian, Lin
    Sakura, Ryo
    Yamaguchi, Takashi
    Hayashi, Gen
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 1412 - 1419
  • [28] Experimental study on fatigue property of Q460 high-strength steel and its bolted connections
    Guo H.
    Huang Y.
    Liu Y.
    Jian Z.
    2018, Science Press (39): : 165 - 172
  • [29] Experimental study on fatigue behavior of Q690D high-strength steel bolted connections
    Q690D高强钢螺栓连接疲劳性能试验研究
    Liu, Yunhe (liuyunhe1968@163.com), 2018, Chinese Society of Civil Engineering (51):
  • [30] Experimental Study on the Slip Behaviour of Stainless Steel High-Strength Bolted Connections with a New Surface Treatment
    Zhang, Tianxiong
    Bu, Yidu
    Wang, Yuanqing
    Chen, Zhihua
    He, Wei
    MATERIALS, 2022, 15 (16)