Biomechanical Evaluation of Proximal Hamstring Repair: All-Suture Anchor Versus Titanium Suture Anchor

被引:5
|
作者
Otto, Alexander [1 ,2 ,3 ]
DiCosmo, Alyssa M. [1 ]
Baldino, Joshua B. [1 ]
Mehl, Julian [1 ,2 ]
Obopilwe, Elifho [1 ]
Cote, Mark P. [1 ]
Imhoff, Andreas B. [1 ,2 ]
Beitzel, Knut [1 ,2 ,4 ]
Mazzocca, Augustus D. [1 ,2 ]
Coyner, Katherine [1 ,2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[2] Tech Univ Munich, Dept Orthopaed Sports Med, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
[4] ATOS Orthoparc Klin Koln, Cologne, Germany
关键词
proximal hamstring avulsion; hip; all-suture anchor; titanium suture anchor; biomechanics; proximal hamstring repair; SURGICAL REPAIR; AVULSION INJURIES; TENDON RUPTURES; OUTCOMES; SPORTS; ORIGIN; TAPE;
D O I
10.1177/2325967119892925
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal hamstring avulsions are severe tendon injuries and are commonly sports-related. Open and endoscopic techniques as well as different anchor configurations have already been described for proximal hamstring repair. Novel all-suture anchors have been developed to provide decreased bone loss during placement and reduced occupied bone volume when compared with titanium suture anchors. Hypothesis: Complete proximal hamstring avulsions repaired with all-suture anchors will demonstrate equal load to failure and comparable displacement under cyclic loading when compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Complete proximal hamstring avulsions were created in 18 paired cadaveric specimens (mean +/- SD age, 63.0 +/- 10.4 years). Either all-suture anchors or titanium suture anchors were used for repair. Cyclic loading from 10 to 125 N at 1 Hz was performed for 1500 cycles with a material testing machine. Displacement was assessed along anterior and posterior aspects of the tendon repair with optical tracking. Specimens were loaded to failure at a rate of 120 mm/min. Displacement, load to failure, and repair construct stiffness were compared between matched pairs with the Wilcoxon signed-rank test. Correlations were determined by Spearman rho analysis. Results: The all-suture anchors showed significantly higher load-to-failure values when compared with the titanium anchor repairs (799.64 +/- 257.1 vs 573.27 +/- 89.9 N; P = .008). There was no significant difference in displacement between all-suture anchors and titanium suture anchors at the anterior aspect (6.60 +/- 2.2 vs 5.49 +/- 1.1 mm; P = .26) or posterior aspect (5.87 +/- 2.08 vs 5.23 +/- 1.37 mm; P = .678) of the repaired hamstring tendons. Conclusion: All-suture anchors demonstrated similar displacement and superior load to failure when compared with titanium suture anchors.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Biomechanical evaluation of a hybrid suture and anchor-based hip capsular repair
    Degen, Ryan M.
    Pasic, Nick
    Baha, Pardis
    Getgood, Alan
    Burkhart, Timothy A.
    CLINICAL BIOMECHANICS, 2021, 81
  • [42] Retrospective Comparative Analysis of Clinical and Functional Outcome After Arthroscopic Bankart Repair using All-Suture Anchor and Metal Anchor
    Jain, V
    Gupta, H.
    Mehta, N.
    Joshi, D.
    Ajay
    Kataria, H.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2024, 18 (01) : 11 - 18
  • [43] All-Suture Anchor Settling After Arthroscopic Repair of Small and Medium Rotator Cuff Tears
    Ro, Kyunghan
    Rhee, Sung-Min
    Kim, Jung Youn
    Kim, Myung Seo
    Kim, Jong Dae
    Lee, Hojin
    Rhee, Yong Girl
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (14): : 3483 - 3490
  • [44] Biomechanical comparison of screw-in suture anchor–suture combinations used for Bankart repair
    Brad S. Sparks
    John Nyland
    Akbar Nawab
    Ethan Blackburn
    Ryan Krupp
    David N. M. Caborn
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 321 - 327
  • [45] All-Suture Anchor Onlay Fixation for Medial Patellofemoral Ligament Reconstruction: A Biomechanical Comparison of Fixation Constructs
    Smith, Benjamin L.
    Bedi, Asheesh
    Hauck, Oliver L.
    Wijdicks, Coen A.
    Riboh, Jonathan C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2024, 12 (11)
  • [46] Mini-Open Subpectoral Biceps Tenodesis With an All-Suture Anchor
    Christian, David R.
    Redondo, Michael L.
    Cvetanovich, Gregory L.
    Beer, Adam J.
    Cole, Brian J.
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 105 - 109
  • [47] A biomechanical assessment of a novel, low-cost all-suture anchor in a flexor digitorum profundus model
    Prasai, Tanup
    Huntington, Lachlan S.
    Ackland, David
    Tham, Stephen K. Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (06) : 654 - 656
  • [48] Editorial Commentary: Size Matters: Biomechanical Analysis of All-Suture Suture-Anchor Fixation Compared to Conventional Suture Anchors and Interference Screws for Biceps Tenodesis
    Taylor, Samuel A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (06): : 1769 - 1770
  • [49] BIOMECHANICAL COMPARISON OF OPEN TRANSOSSEOUS VERSUS ARTHROSCOPIC SUTURE ANCHOR REPAIR OF THE SUBSCAPULARIS TENDON
    Wheeler, Daniel J.
    Garabekyan, Tigran
    Lugo, Roberto
    Buckley, Jenni M.
    Lotz, Marielena
    Lotz, Jeffrey C.
    Ma, C. Benjamin
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 679 - 680
  • [50] A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries
    Spang, Jeffrey T.
    Weinhold, Paul S.
    Karas, Spero G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 509 - 514