Evaluation of Anti-dsDNA Antibody Tests: Crithidia luciliae Immunofluorescence Test, Immunoblot, Enzyme-linked Immunosorbent Assay, Chemiluminescence Immunoassay

被引:7
|
作者
Yang, Jin-young [1 ]
Oh, Eun-Jee [1 ]
Kim, Yonggoo [1 ]
Park, Yeon-Joon [1 ]
机构
[1] Catholic Univ Korea Sch Med, Dept Lab Med, Seoul, South Korea
来源
KOREAN JOURNAL OF LABORATORY MEDICINE | 2010年 / 30卷 / 06期
关键词
Anti-dsDNA; Crithidia luciliae immunofluorescence test; ELISA; Chemiluminescence immunoassay; Immunoblot assay; SYSTEMIC-LUPUS-ERYTHEMATOSUS; DOUBLE-STRANDED DNA; ANTINUCLEAR AUTOANTIBODIES; DEFINED SPECIFICITIES; RHEUMATIC DISEASES; LABORATORY ASSAYS; LINE IMMUNOASSAY; ELISA; DIAGNOSIS; CLASSIFICATION;
D O I
10.3343/kjlm.2010.30.6.675
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background : Anti-double stranded DNA antibody (anti-dsDNA) test is useful for the diagnosis and monitoring of systemic lupus erythematosus (SLE). Although several methods are available, none of them is completely satisfactory and differences among them have been reported. We evaluated the diagnostic performance of 6 commercial kits for anti-dsDNA detection. Methods : A total of 142 sera (SLE [N=74], other systemic rheumatic diseases [N=50], other diseases [N=18]) were tested by 6 different assay kits using different antigenic sources of DNA: Crithidia luciliae immunofluorescence test (CLIFF), salmon testes (immunoblot, IB), human (ELISA l), salmon testes with nucleosome linker (ELISA II), plasmid (ELISA III), and synthetic oligonucleotides (chemiluminescence immunoassay, CLIA). Results : With manufacturers' cut-off values, 6 test kits showed sensitivities of 55.4-91.9%. ELISA I had a greater sensitivity than the other five assays (P<0.001). The specificities of ELISA II, ELISA Ill, CLIA, and CLIFF were higher than those of ELISA I and IB (P<0.05). In ROC curve analysis, 3 ELISA kits and CLIA showed AUC values of 0.845-0.893, and revealed no significant differences among them (P>0.05). With cut-off values set at 95% of specificity, ELISA II had a higher sensitivity than ELISA III (63.5% vs. 41.9%, P<0.05). IB had poor concordance rates with other assays (42.0-65.0%). Pearson correlation coefficients among 4 quantitative assays were 0.667-0.798. Conclusions : Six different assays showed various performances depending on the methods and cut-off values used. Except IB, the other five assays can be used for the detection of anti-dsDNA. (Korean J Lab Med 2010;30:675-84)
引用
收藏
页码:675 / 684
页数:10
相关论文
共 50 条
  • [31] Preparation of anti-sulfamethazine antibody and establishment of enzyme-linked immunosorbent assay for sulfamethazine
    China Institute of Atomic Energy, P.O.Box 275-39, Beijing 102413, China
    Yuanzineng Kexue Jishu, 2008, SUPPL. (63-67):
  • [32] ENZYME-LINKED IMMUNOSORBENT-ASSAY - A RAPID REPRODUCIBLE TEST FOR THE MEASUREMENT OF RABIES ANTIBODY
    NICHOLSON, KG
    PRESTAGE, H
    JOURNAL OF MEDICAL VIROLOGY, 1982, 9 (01) : 43 - 49
  • [33] Evaluation of vircell enzyme-linked immunosorbent assay and indirect immunofluorescence assay for detection of antibodies against Legionella pneumophila
    Diederen, BMW
    Kluytmans, JAJW
    Peeters, MF
    CLINICAL AND VACCINE IMMUNOLOGY, 2006, 13 (03) : 361 - 364
  • [34] Preparation of an anti-thiamethoxam monoclonal antibody for development of an indirect competitive enzyme-linked immunosorbent assay and a colloidal gold immunoassay
    Ye, Liya
    Wu, Xiaoling
    Xu, Liguang
    Zheng, Qiankun
    Kuang, Hua
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 1173 - 1183
  • [35] Multicentric evaluation of the DiaMed enzyme-linked immunosorbent assay malaria antibody test for screening of blood donors for malaria
    Elghouzzi, M. -H.
    Senegas, A.
    Steinmetz, T.
    Guntz, P.
    Barlet, V.
    Assal, A.
    Gallian, P.
    Volle, P.
    Chuteau, C.
    Beolet, M.
    Berrebi, S.
    Filisetti, D.
    Doderer, C.
    Abdelrahman, T.
    Candolfi, E.
    VOX SANGUINIS, 2008, 94 (01) : 33 - 40
  • [36] Enzyme-linked immunosorbent assay IgG: Antibody avidity test for single sample serologic evaluation of measles vaccines
    deSouza, VAUF
    Pannuti, CS
    Sumita, LM
    deAndrade, HF
    JOURNAL OF MEDICAL VIROLOGY, 1997, 52 (03) : 275 - 279
  • [37] Comparative study of indirect immunofluorescence, enzyme-linked immunosorbent assay, and the Tzanck smear test for the diagnosis of pemphigus
    Zhou, Tingting
    Fang, Siyue
    Li, Chunlei
    Hua, Hong
    JOURNAL OF ORAL PATHOLOGY & MEDICINE, 2016, 45 (10) : 786 - 790
  • [38] ANTINUCLEAR ANTIBODY SCREENING IN AIH SHOULD BE PERFORMED BY INDIRECT FLUORESCENT IMMUNOASSAY BUT NOT BY ENZYME-LINKED IMMUNOSORBENT ASSAY
    Takahashi, Hiroki
    Nakagawa, Ryo
    Nakano, Masanori
    Saeki, Chisato
    Kuniyasu, Yushi
    Zeniya, Mikio
    HEPATOLOGY, 2011, 54 : 910A - 910A
  • [39] ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR THE INDIRECT ANTI-HUMAN GLOBULIN TEST
    OSBORNE, WRA
    GIBLETT, ER
    ACTA HAEMATOLOGICA, 1980, 63 (03) : 124 - 127
  • [40] ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR EVALUATION OF ANTIBODY TO CANINE-DISTEMPER VIRUS
    NOON, KF
    ROGUL, M
    BINN, LN
    KEEFE, TJ
    MARCHWICKI, RH
    APPEL, MJ
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1980, 41 (04) : 605 - 609