Aortic Valve Replacement in Octogenarians With Prior Cardiac Surgery

被引:12
|
作者
Timek, Tomasz A.
Turfe, Zaahir
Hooker, Robert L.
Davis, Alan T.
Willekes, Charles L.
Murphy, Edward T.
Bove, Theodore J.
Heiser, John C.
Patzelt, Lawrence H.
机构
[1] Michigan State Univ, Meijer Heart & Vasc Inst Spectrum Hlth, Dept Cardiothorac Surg, Coll Human Med,Grand Rapids Educ Partners, Grand Rapids, MI USA
[2] Michigan State Univ, Dept Surg, Grand Rapids, MI USA
来源
ANNALS OF THORACIC SURGERY | 2015年 / 99卷 / 02期
关键词
QUALITY-OF-LIFE; LONG-TERM SURVIVAL; AGED GREATER-THAN-OR-EQUAL-TO-80 YEARS; ELDERLY-PATIENTS; TRANSCATHETER; IMPLANTATION; OUTCOMES; RISK; INTERVENTIONS; METAANALYSIS;
D O I
10.1016/j.athoracsur.2014.08.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Transcatheter aortic valve implantation (TAVI) has been advocated for very elderly patients with aortic stenosis, and prior cardiac surgery as a less invasive treatment option. Although surgical aortic valve replacement (AVR) is safe and effective in selected elderly patients, the perioperative and mid-term outcomes of AVR in very elderly with prior cardiac surgery are unknown. Methods. The Society of Thoracic Surgeons (STS) Database at our center enrolled 3,735 patients after AVR since 1997. In this time interval, we identified 61 patients 80 years and older who underwent AVR for severe AS or failed aortic bioprosthesis after having prior cardiac surgery. All clinical parameters were derived from the STS database. Follow-up mortality was assessed using the Social Security Death Index. Results. The average age of the patients was 83 +/- 2 years, 77% were male, and 75% underwent an isolated coronary artery bypass graft (CABG) as their first cardiac procedure. The mean ejection fraction was 0.53 +/- 0.13. The CABG was performed concurrently in 49% of patients at the time of redo sternotomy and AVR. Stented bioprosthesis was implanted in 61% of patients and stentless in 39%. Perioperative mortality was 1.6% (1 of 61). One, 3, 5, and 7 year survival rates were 85%, 69%, 63%, and 43%, respectively. Patients with AVR only had similar survival to patients who underwent concomitant AVR and CABG. Type of aortic prosthesis did not influence postoperative survival. Conclusions. In selected patients over the age of 80 with history of prior cardiac surgery, AVR can be performed safely with very good mid-term outcomes. Age alone should not be exclusion criteria for surgical AVR in octogenarians with prior cardiac surgery. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:518 / 523
页数:6
相关论文
共 50 条
  • [41] Simultaneous Aortic and Mitral Valve Replacement in Octogenarians: A Viable Option?
    Maleszka, Ariane
    Kleikamp, Georg
    Zittermann, Armin
    Serrano, Maria R. G.
    Koerfer, Reiner
    ANNALS OF THORACIC SURGERY, 2008, 86 (06): : 1804 - 1808
  • [42] Aortic valve replacement for octogenarians: Are small valves bad? - Discussion
    Schaff, HV
    Medalion
    Kurlansky, PA
    Jamieson, WRE
    ANNALS OF THORACIC SURGERY, 1998, 66 (03): : 705 - 706
  • [43] Risk factors and survival after aortic valve replacement in octogenarians
    Mistiaen, W
    Van Cauwelaert, P
    Muylaert, P
    Wuyts, F
    Harrisson, F
    Bortier, H
    JOURNAL OF HEART VALVE DISEASE, 2004, 13 (04): : 538 - 544
  • [44] Valve Replacement for Moderate Aortic Stenosis in Octogenarians Undergoing Revascularization
    Lopez-Marco, Ana
    Tymko, Rebecca
    Von Oppell, Ulrich
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (04): : 405 - 411
  • [45] Conventional Aortic Valve Replacement in Octogenarians - A Single Center Experience
    Roberts, J. D.
    Troutman, G.
    Weiss, M.
    James, W. U.
    CARDIOLOGY, 2012, 121 (02) : 134 - 134
  • [46] Current Outcomes after Isolated Aortic Valve Replacement in the Octogenarians
    Senage, Thomas
    Marie, Basile
    Cueff, Caroline
    Rozec, Bertrand
    Pattier, Sabine
    Roussel, Jean-Christian
    Thierry, Le Tourneau
    CARDIOLOGY, 2016, 134 (02) : 238 - 238
  • [47] Aortic Valve Replacement in Octogenarians: Utility of Risk Stratification With EuroSCORE
    Leontyev, Sergey
    Walther, Thomas
    Borger, Michael A.
    Lehmann, Sven
    Funkat, Anne K.
    Rastan, Ardawan
    Kempfert, Joerg
    Falk, Volkmar
    Mohr, Friedrich W.
    ANNALS OF THORACIC SURGERY, 2009, 87 (05): : 1440 - 1445
  • [48] Valve surgery in octogenarians with a "porcelain" aorta and aortic insufficiency
    Greelish, JP
    Soltesz, EG
    Byrne, JG
    JOURNAL OF CARDIAC SURGERY, 2002, 17 (04) : 285 - 288
  • [49] Aortic valve replacement in octogenarians: performance analysis of EuroSCORE II
    D Hernandez-Vaquero
    R Diaz
    JC Llosa
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [50] THE RISK IN PREDICTING OUTCOMES FOR OCTOGENARIANS UNDERGOING AORTIC VALVE REPLACEMENT
    Buu-Khanh Lam
    Elmestekawy, ElSayed
    Tran, Diem T.
    Dupuis, Jean-Yves
    McDonald, Bernard
    Ruel, Marc
    Mesana, Thierry G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1361 - E1361