Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations

被引:11
|
作者
Duetschler, Alisha [1 ,2 ]
Bauman, Grzegorz [3 ,4 ]
Bieri, Oliver [3 ,4 ]
Cattin, Philippe C. [3 ,5 ]
Ehrbar, Stefanie [6 ,7 ]
Engin-Deniz, Georg [1 ,2 ]
Giger, Alina [3 ,5 ]
Josipovic, Mirjana [8 ]
Jud, Christoph [3 ,5 ]
Krieger, Miriam [1 ,2 ]
Nguyen, Damien [3 ,4 ]
Persson, Gitte F. [8 ,9 ,10 ]
Salomir, Rares [11 ,12 ]
Weber, Damien C. [1 ,6 ,13 ]
Lomax, Antony J. [1 ,2 ]
Zhang, Ye [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Forschungsstr 111, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[4] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Basel, Switzerland
[5] Univ Basel, Ctr Med Image Anal & Nav, Allschwil, Switzerland
[6] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[7] Univ Zurich, Zurich, Switzerland
[8] Copenhagen Univ Hosp, Dept Oncol, Rigshosp, Copenhagen, Denmark
[9] Copenhagen Univ Hosp, Dept Oncol, Herlev Gentofte Hosp, Herlev, Denmark
[10] Univ Copenhagen, Fac Med Sci, Dept Clin Med, Copenhagen, Denmark
[11] Univ Geneva, Fac Med, Image Guided Intervent Lab 949, Geneva, Switzerland
[12] Univ Hosp Geneva, Radiol Div, Geneva, Switzerland
[13] Univ Bern, Dept Radiat Oncol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
4D imaging; 4DMRI; 4D numerical phantom; intrafraction motion; proton therapy; RESPIRATORY MOTION; XCAT PHANTOM; PROTON; CT; SIMULATION; THERAPY; MODEL; REGISTRATION; DEFORMATION; FRAMEWORK;
D O I
10.1002/mp.15591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding "ground truths," have been developed and validated for 4D radiotherapy applications. Methods The phantoms are based on CTs providing density information and motion from multi-breathing-cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter-subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. Results Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior-inferior tumor motion amplitude of 7 +/- 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). Conclusion We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible "ground truth" deformation vector fields of each 4DCT(MRI). The open-source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.
引用
收藏
页码:2890 / 2903
页数:14
相关论文
共 50 条
  • [21] Evaluation of a novel anthropomorphic thorax phantom with a dynamic lung using 4DCT
    Lustermans, Didier
    Abdulrahim, Roua
    Reniers, Brigitte
    Verhaegen, Frank
    Fonseca, Gabriel Paiva
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3273 - S3275
  • [22] Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study
    Pollock, S.
    Kipritidis, J.
    Lee, D.
    Bernatowicz, K.
    Keall, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3301 - 3301
  • [23] Establishing a framework to implement 4D XCAT Phantom for 4D radiotherapy research
    Panta, Raj K.
    Segars, Paul
    Yin, Fang-Fang
    Cai, Jing
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (04) : 565 - 570
  • [24] A deformable phantom for 4D radiotherapy verification: Design and image registration evaluation
    Serban, Monica
    Heath, Emily
    Stroian, Gabriela
    Collins, D. Louis
    Seuntjens, Jan
    MEDICAL PHYSICS, 2008, 35 (03) : 1094 - 1102
  • [25] Image-based retrospective 4D MRI in external beam radiotherapy: A comparative study with a digital phantom
    Paganelli, Chiara
    Kipritidis, John
    Lee, Danny
    Baroni, Guido
    Keall, Paul
    Riboldi, Marco
    MEDICAL PHYSICS, 2018, 45 (07) : 3161 - 3172
  • [26] Development of a 3D dynamic verification phantom for 4DCT and IMRT
    Hubenschmidt, J
    Parikh, P
    Low, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1822 - 1822
  • [27] 4DCT ventilation function image-based functional lung protection for esophageal cancer radiotherapy
    Zhou, Pixiao
    Wang, Ruihao
    Yu, Hui
    Liao, Zhiwei
    Zhang, Ying
    Huang, Zouqin
    Zhang, Shuxu
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (05) : 445 - 455
  • [28] 4DCT ventilation function image-based functional lung protection for esophageal cancer radiotherapy
    Pixiao Zhou
    Ruihao Wang
    Hui Yu
    Zhiwei Liao
    Ying Zhang
    Zouqin Huang
    Shuxu Zhang
    Strahlentherapie und Onkologie, 2023, 199 : 445 - 455
  • [29] Application of a Dynamic Lung Phantom to Commissioning 4D Imaging Systems for Radiotherapy
    Lowe, M.
    Webster, G.
    Rowbottom, C.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S44 - S44
  • [30] Towards Quality Assurance of 4D Radiotherapy Using a Deformable Lung Phantom
    Serban, M.
    Alexander, A.
    Seuntjens, J.
    MEDICAL PHYSICS, 2008, 35 (06)