SC-Cut Quartz Resonators for Dynamic Liquid Viscosity Measurements

被引:7
|
作者
Ju, Shuai [1 ]
Zhang, Chen [1 ]
Zahedinejad, Parham [1 ]
Zhang, Haifeng [1 ]
机构
[1] Univ North Texas, Dept Mech & Energy Engn, Denton, TX 76207 USA
关键词
Viscosity; Resonators; Fluids; Vibrations; Liquids; Frequency measurement; Acoustics; Piezoelectric; quartz resonator; stress compensated (SC)-cut; thickness-shear; viscosity; CRYSTAL RECTANGULAR-PLATES; FORCED VIBRATIONS; DENSITY; SENSOR; MICROBALANCE; FREQUENCY; MIXTURES; SOLUBILITY; EXCITATION; CONTACT;
D O I
10.1109/TUFFC.2021.3096782
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article proposes an innovative viscosity sensor based on the thickness-shear vibration of stress compensated (SC)-cut quartz resonator. The thickness-shear mode is first analyzed and further studied with fluid-structure interaction between the resonator and the viscous fluid loading. The characteristic equation is derived based on the 3-D linear piezoelectric equations and solved for sensitivity analysis. Then laboratory experiment is carried out to validate the theory. To conduct the viscosity measurement, the SC-cut quartz resonator is integrated with a U-tube test fixture, which is designed and fabricated for sensor housing to avoid the influence of the mass of the fluid. The resonator is tested with various viscosities by tuning the ratio of glycerol/water mixture. Experiment results show consistency with the analytical solution, which together present an improved sensitivity of viscosity measurement by using SC-cut quartz resonator comparing to other resonator-based viscosity sensors. The proposed viscosity sensor is sensitive, accurate, and portable, and therefore can be applied to real-time, on-site measurement or sampling of fluidic samples.
引用
收藏
页码:3616 / 3623
页数:8
相关论文
共 50 条
  • [31] MECHANICAL EFFECTS COMPENSATION FOR SC-CUT CRYSTAL
    DELAITE, R
    VALENTIN, JP
    REVUE DE PHYSIQUE APPLIQUEE, 1987, 22 (02): : 119 - 123
  • [32] Forced vibrations of SC-cut quartz crystal rectangular plates with partial electrodes by the Lee plate equations
    Wu, Rongxing
    Wang, Wenjun
    Chen, Guijia
    Du, Jianke
    Ma, Tingfeng
    Wang, Ji
    ULTRASONICS, 2016, 65 : 338 - 344
  • [33] LOW-NOISE VHF CRYSTAL-CONTROLLED OSCILLATOR UTILIZING DUAL SC-CUT RESONATORS
    DRISCOLL, MM
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 121 - 121
  • [35] Comparison of passive and active aging of SC-CUT and AT-CUT crystals
    Neubig, BW
    PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), 1996, : 316 - 322
  • [36] An Analysis of the Frequency-temperature Relations of SC-cut Quartz Crystal Plates with the Lee Plate Theory
    Ma, Tingfeng
    Wang, Wejun
    Wu, Rongxing
    Du, Jianke
    Huang, Dejin
    Wang, Ji
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1013 - 1016
  • [37] VISCOSITY MEASUREMENT WITH QUARTZ RESONATORS
    DYACHENK.BP
    MEASUREMENT TECHNIQUES-USSR, 1970, (08): : 1240 - &
  • [38] Viscosity measurements of liquids under pressure by using the quartz crystal resonators
    Daridon, J. -L.
    Cassiede, M.
    Paillol, J. H.
    Pauly, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (09):
  • [39] An unique design of temperature compensated SC-Cut crystal oscillators
    Tokyo Metropolitan University, Hachioji, Tokyo 192-0397, Japan
    不详
    IEEJ Trans. Electron. Inf. Syst., 2007, 8 (1192-1193): : 1192 - 1193
  • [40] Free and forced vibrations of SC-cut quartz crystal rectangular plates with the first-order Mindlin plate equations
    Wu, Rongxing
    Wang, Wenjun
    Chen, Guijia
    Chen, Hui
    Ma, Tingfeng
    Du, Jianke
    Wang, Ji
    ULTRASONICS, 2017, 73 : 96 - 106