Mapping Contact Force during Catheter Ablation for the Treatment of Atrial Fibrillation: New Insights into Ablation Therapy

被引:0
|
作者
Karim, Rashed [1 ]
Gao, Gang [1 ]
Harrison, James [1 ]
Arujuna, Aruna [1 ]
Lambert, Hendrik [3 ]
Leo, Giovanni [3 ]
Gill, Jaswinder [2 ]
Razavi, Reza [1 ]
Schaeffter, Tobias [1 ]
O'Neill, Mark [2 ]
Rhode, Kawal S. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci, London SE1 7EH, England
[2] St Thomas Hosp, Dept Cardiol, London SE1 7EH, England
[3] Endosense SA, Geneva, Switzerland
关键词
catheter ablation; atrial fibrillation; contact force; visualization techniques; image-guided intervention;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The distribution of ablation catheter contact force may be important for elucidating the mechanisms of pulmonary vein (PV) reconnection following PV isolation (PVI) for the treatment of paroxysmal atrial fibrillation (PAF). A novel method was developed for the visualisation of tissue contact force on left atrial models derived from segmented MRI data and the approach was tested in 3 patients. The left atrium was automatically segmented from preprocedural whole-heart cardiac magnetic resonance (CMR) scans in three patients undergoing circumferential PVI for catheter ablation of PAF. During the procedure, the CMR shell was overlaid on to real-time fluoroscopy using the EP Navigator (EPN) software (Philips Healthcare, The Netherlands) and registered using the trachea and intracardiac catheters. Using a wide area circumferential approach to encircle ipsilateral pairs of PVs, the position of each radiofrequency (RF) application (25W for 40s) was recorded on the CMR shell using the point tagging feature of EPN. Using a contact force-sensing ablation catheter (TactiCath, Endosense, Switzerland), the contact force-time integral (FTI) for each registered ablation point was recorded. The FTI for each point was then projected on to the CMR shell with a circular diameter of 10mm using custom-made software. This radius of force distribution was chosen to reflect the typical accuracy of location of the mapping catheter and also to take into account the motion of the catheter during the RF application. 4 vein PVI and FTI maps were achieved in all patients (see figure 1 for example). The mean FTI applied to each side of the left atrium was recorded in gram seconds. The total and regional FTIs applied Fig. 1. The FTI map for each patient in three separate views (from left to right: posterior, right PVs and anterior to achieve PVI differed between and within patients respectively, but in an inconsistent manner. The FTI map on the pre-segmented atrial shell provides an intuitive post-procedural assessment of the tissue-contact force achieved during RF delivery. The FTI is less consistent between patients for the RPVs than for the LPVs, perhaps reflecting patient-specific technical challenges. Comparison of FTI maps with post-ablation delayed enhancement, T2W MRI and clinical outcome data may assist in understanding the mechanisms of effective lesion delivery and of PV reconnection after ablation.
引用
收藏
页码:302 / +
页数:2
相关论文
共 50 条
  • [31] Contact force during ablation of persistent atrial fibrillation and electrogram attenuation
    Ullah, W.
    Hunter, R.
    Lovell, M.
    Dhillon, O.
    Diab, I.
    Dhinoja, M.
    Earley, M.
    Sporton, S.
    Schilling, R.
    EUROPEAN HEART JOURNAL, 2013, 34 : 429 - 430
  • [32] Catheter ablation for initial treatment of atrial fibrillation
    Lewalter, T.
    Nitschmann, S.
    INTERNIST, 2021, 62 (07): : 796 - 800
  • [33] Catheter ablation of atrial fibrillation: A treatment frontier
    Domanski, Michael
    Waldo, Albert L.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (03) : 141 - 143
  • [34] Catheter ablation of atrial fibrillation: A treatment frontier
    Michael Domanski
    Albert L. Waldo
    Journal of Interventional Cardiac Electrophysiology, 2006, 15 : 141 - 143
  • [35] Treatment of Atrial Fibrillation: Role of Catheter Ablation
    Kircher, S.
    Gaspar, T.
    Arya, A.
    Hindricks, G.
    JOURNAL FUR KARDIOLOGIE, 2009, 16 : 13 - 16
  • [36] Atrial Rhythm Influences Catheter Tissue Contact During Radiofrequency Ablation of Atrial Fibrillation
    Matsuda, Hisao
    Parwani, Abdul S.
    Attanasio, Philipp
    Huemer, Martin
    Wutzler, Alexander
    Blaschke, Florian
    Haverkamp, Wilhelm
    Boldt, Leif-Hendrik
    CIRCULATION, 2014, 130
  • [37] A new approach for catheter ablation of atrial tachycardia following atrial fibrillation ablation
    Faustino, Massimiliano M.
    Capuzzi, Donato
    Agricola, Tullio
    Ciammetti, Donatella
    Pecce, Piero
    Santarella, Luigi
    Pizzi, Carmine
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2012, 13 (12) : 795 - 804
  • [38] New technologies for catheter ablation of atrial fibrillation
    Gerstenfeld E.P.
    Current Treatment Options in Cardiovascular Medicine, 2011, 13 (5) : 393 - 401
  • [39] Catheter ablation of atrial fibrillation in the young: insights from the German Ablation Registry
    K. R. Julian Chun
    Boris Schmidt
    Karl-Heinz Kuck
    Dietrich Andresen
    Stefan Willems
    Stefan G. Spitzer
    Ellen Hoffmann
    Burghard Schumacher
    Lars Eckardt
    Karlheinz Seidl
    Claus Jünger
    Martin Horack
    Johannes Brachmann
    Jochen Senges
    Clinical Research in Cardiology, 2013, 102 : 459 - 468
  • [40] Catheter ablation of atrial fibrillation in the young: insights from the German Ablation Registry
    Chun, K. R. Julian
    Schmidt, Boris
    Kuck, Karl-Heinz
    Andresen, Dietrich
    Willems, Stefan
    Spitzer, Stefan G.
    Hoffmann, Ellen
    Schumacher, Burghard
    Eckardt, Lars
    Seidl, Karlheinz
    Juenger, Claus
    Horack, Martin
    Brachmann, Johannes
    Senges, Jochen
    CLINICAL RESEARCH IN CARDIOLOGY, 2013, 102 (06) : 459 - 468