Multi-Rigid Image Segmentation and Registration for the Analysis of Joint Motion From Three-Dimensional Magnetic Resonance Imaging

被引:12
|
作者
Hu, Yangqiu [1 ,2 ]
Ledoux, William R. [3 ,4 ,5 ]
Fassbind, Michael [3 ]
Rohr, Eric S. [3 ]
Sangeorzan, Bruce J. [3 ,5 ]
Haynor, David [1 ,2 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] VA Ctr Excellence Limb Loss Prevent & Prosthet En, Seattle, WA 98108 USA
[4] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[5] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
关键词
joint motion; MRI; segmentation; registration; visualization; ANKLE; SUBTALAR; KINEMATICS; FOOT; MR;
D O I
10.1115/1.4005175
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo magnetic resonance imaging (MRI) scans and its application to the analysis of foot and ankle joint motion. Using an MRI-compatible positioning device, a foot was scanned in a single neutral and seven other positions ranging from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. A segmentation method combining graph cuts and level set was developed. In the subsequent registration step, a separate rigid body transformation for each bone was obtained by registering the neutral position dataset to each of the other ones, which produced an accurate description of the motion between them. The segmentation algorithm allowed a user to interactively delineate 14 foot bones in the neutral position volume in less than 30 min total (user and computer processing unit [CPU]) time. Registration to the seven other positions took approximately 10 additional minutes of user time and 5.25 h of CPU time. For validation, our results were compared with those obtained from 3DViewnix, a semiautomatic segmentation program. We achieved excellent agreement, with volume overlap ratios greater than 88% for all bones excluding the intermediate cuneiform and the lesser metatarsals. For the registration of the neutral scan to the seven other positions, the average overlap ratio is 94.25%, while the minimum overlap ratio is 89.49% for the tibia between the neutral position and position 1, which might be due to different fields of view (FOV). To process a single foot in eight positions, our tool requires only minimal user interaction time (less than 30 min total), a level of improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications. [DOI: 10.1115/1.4005175]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Application of three-dimensional magnetic resonance image registration for monitoring hip joint diseases
    Takao, M
    Sugano, N
    Nishii, T
    Tanaka, H
    Masumoto, J
    Miki, H
    Sato, Y
    Tamura, S
    Yoshikawa, H
    MAGNETIC RESONANCE IMAGING, 2005, 23 (05) : 665 - 670
  • [2] In vivo three-dimensional wrist motion analysis using magnetic resonance imaging and volume-based registration
    Goto, A
    Moritomo, H
    Murase, T
    Oka, K
    Sugamoto, K
    Arimura, T
    Masumoto, J
    Tamura, S
    Yoshikawa, H
    Ochi, T
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) : 750 - 756
  • [3] Magnetic resonance imaging of the equine metacarpophalangeal joint: Three-dimensional reconstruction and anatomic analysis
    Martinelli, MJ
    Kuraiashkin, IV
    Carragher, BO
    Clarkson, RB
    Baker, GJ
    VETERINARY RADIOLOGY & ULTRASOUND, 1997, 38 (03) : 193 - 199
  • [4] Three-dimensional magnetic resonance myocardial motion tracking from a single image plane
    Abd-Elmoniem, Khaled Z.
    Osman, Nael F.
    Prince, Jerry L.
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) : 92 - 102
  • [5] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Zhang, Bao
    Arola, Dwayne D.
    Roys, Steve
    Gullapalli, Rao P.
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (04) : 573 - 585
  • [6] Three-dimensional Elastic Image Registration Based on Strain Energy Minimization: Application to Prostate Magnetic Resonance Imaging
    Bao Zhang
    Dwayne D. Arola
    Steve Roys
    Rao P. Gullapalli
    Journal of Digital Imaging, 2011, 24 : 573 - 585
  • [7] Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    Mercier, Laurence
    Fonov, Vladimir
    Haegelen, Claire
    Del Maestro, Rolando F.
    Petrecca, Kevin
    Collins, D. Louis
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) : 125 - 136
  • [8] Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery
    Laurence Mercier
    Vladimir Fonov
    Claire Haegelen
    Rolando F. Del Maestro
    Kevin Petrecca
    D. Louis Collins
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 125 - 136
  • [9] Retrospective rigid motion correction of three-dimensional magnetic resonance fingerprinting of the human brain
    Kurzawski, Jan W.
    Cencini, Matteo
    Peretti, Luca
    Gomez, Pedro A.
    Schulte, Rolf F.
    Donatelli, Graziella
    Cosottini, Mirco
    Cecchi, Paolo
    Costagli, Mauro
    Retico, Alessandra
    Tosetti, Michela
    Buonincontri, Guido
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2606 - 2615
  • [10] Clinical applications of three-dimensional magnetic resonance image analysis
    Bauer, GR
    Hillstrom, HJ
    Udupa, JK
    Hirsch, BE
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1996, 86 (01): : 33 - 37