Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2

被引:19
|
作者
Hong, Christine
Peter Truong
Ha Na Song
Wu, Benjamin M. [2 ,3 ,4 ]
Moon, Won [1 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Orthodont, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Calif NanoSyst Inst, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Sch Engn, Los Angeles, CA 90095 USA
关键词
Mini-implants; TADs; Stability; Buccal bone thickness; Cortical bone; Micro-CT; CORTICAL BONE THICKNESS; DISTAL MOVEMENT; ANCHORAGE; ROOT; DISTALIZATION; PROXIMITY; FAILURE; LENGTH; MOLARS; SHAPE;
D O I
10.2319/031011-176.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the mechanical stability of a newly revised orthodontic mini-implant design (N2) compared with a design introduced in Part 1 of the study (N1) and the most widely-used commercially-available design (CA). To evaluate the mean buccal bone thickness of maxillary and mandibular posterior teeth using cone-beam computed tomography (CBCT). Materials and Methods: From the CBCT scans of 20 patients, six tomographic cross-sections were generated for each tooth. Buccal bone thickness was measured from the most convex point on the bone to the root surface. CA (1.5 mm in diameter and 6 mm in length), N1, and N2 (shorter and narrower than N1) were inserted in simulated bone with cortical and trabecular bone layers. Mechanical stability was compared in vitro through torque and lateral displacement tests. Results: The bone thickness ranged from 2.26 to 3.88 mm. Maximum insertion torque was decreased significantly in N2 compared to N1. However, force levels for all displacement distances and torque ratio were the highest in N2, followed by N1 and CA (alpha = .05). Conclusions: Both torque and lateral displacement tests highlighted the enhanced stability of N2 compared with CA. Design revisions to N1 effectively mitigated N1's high insertion torque and thus potentially reduced microdamage to the surrounding bone. The N2 design is promising as evidenced by enhanced stability and high mechanical efficiency. Moreover, N2 is not limited to placement in interradicular spaces and has the capacity to be placed in the buccal bone superficial to the root surface with diminished risk of endangering nearby anatomic structures during placement and treatment. (Angle Orthod. 201181:1001-1009.)
引用
收藏
页码:1001 / 1009
页数:9
相关论文
共 50 条
  • [21] Advances in orthodontic anchorage with the use of mini-implant techniques
    Cousley, R. R. J.
    Sandlertemporary, P. J.
    BRITISH DENTAL JOURNAL, 2015, 218 (03) : 1 - 6
  • [22] Advances in orthodontic anchorage with the use of mini-implant techniques
    R. R. J. Cousley
    P. J. Sandler
    British Dental Journal, 2015, 218 : E4 - E4
  • [23] A mini-implant for orthodontic anchorage in a deep overbite case
    Ohnishi, H
    Yagi, T
    Yasuda, Y
    Takada, K
    ANGLE ORTHODONTIST, 2005, 75 (03) : 444 - 452
  • [24] Orthodontic Mini-Implant Stability under Continuous or Intermittent Loading: A Histomorphometric and Biomechanical Analysis
    Wu, Yeke
    Xu, Zhenrui
    Tan, Luyuan
    Tan, Lijun
    Zhao, Zhihe
    Yang, Pu
    Li, Yu
    Tang, Tian
    Zhao, Lixing
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 163 - 172
  • [25] The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study)
    Abdalla, Khanda Latif
    Mahmood, Trefa Mohammed Ali
    HELIYON, 2023, 9 (09)
  • [26] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shen, Shuning
    Sun, Yingying
    Zhang, Chen
    Yang, Yongjin
    Li, Zhiren
    Cai, Xingwei
    Duan, Yinzhong
    Li, Tao
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 109 - 116
  • [27] The effect of loading time on the stability of mini-implant
    Lee, Seung-Yeon
    Cha, Jung-Yul
    Yoon, Tae-min
    Park, Young-Chel
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (03): : 149 - 158
  • [28] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [29] Recommended placement torque when tightening an orthodontic mini-implant
    Motoyoshi, M
    Hirabayashi, M
    Uemura, M
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 109 - 114
  • [30] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jörg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 : 1 - 6