In vivo imaging of ocular blood flow using high-speed ultrasound

被引:0
|
作者
Ketterling, Jeffrey A. [1 ]
Urs, Raksha [2 ]
Silverman, Ronald H. [2 ]
机构
[1] Riverside Res, Lizzi Ctr Biomed Engn, New York, NY 10038 USA
[2] Columbia Univ, Dept Ophthalmol, Harkness Eye Inst, Med Ctr, New York, NY 10027 USA
关键词
ULTRAFAST; GPU;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Clinical ophthalmic ultrasound is currently performed with mechanically scanned, single-element probes, but these are unable to provide useful information about blood flow with Doppler techniques. Linear arrays are well-suited for the detection of blood flow, but commercial systems generally exceed FDA ophthalmic safety limits. A high-speed plane-wave ultrasound approach with an 18-MHz linear array was utilized to characterize blood flow in the orbit and choroid. Acoustic intensity was measured and the plane-wave mode was within FDA limits. Data were acquired for up to 2 sec and up to 20,000 frames/s with sets of steered plane-wave transmissions that spanned 2*theta degrees where 0 degrees was normal to the array. Lateral resolution was characterized using compounding from 1 to 50 transmissions and -6-dB lateral beamwidths ranged from 320 to 180 mu m, respectively. Compounded high-frame-rate data were post-processed using a singular value decomposition spatiotemporal filter and then flow was estimated at each pixel using standard Doppler processing methods. A 1-cm diameter rotating scattering phantom and a 2-mm diameter tube with a flow of blood-mimicking fluid were utilized to validate the flow-estimation algorithms. In vivo data were obtained from the posterior pole of the human eye which revealed regions of flow in the choroid and major orbital vessels supplying the eye.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] High-speed imaging in fluids
    Versluis, Michel
    EXPERIMENTS IN FLUIDS, 2013, 54 (02)
  • [42] THE APPROACH TO HIGH-SPEED IMAGING
    MANSFIELD, P
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 804 - 804
  • [43] High-speed AFM imaging
    Ando, Toshio
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2014, 28 : 63 - 68
  • [44] Introduction to high-speed imaging
    Leonardi, M
    EUROPEAN RADIOLOGY, 1997, 7 (Suppl 5) : S164 - S165
  • [45] High-speed imaging spectrometry
    Volin, CE
    Descour, MR
    Dereniak, EL
    IMAGING SPECTROMETRY III, 1997, 3118 : 179 - 183
  • [46] High-speed 3D Ultrasound Imaging Using L1-norm Minimization
    Mimura, Yuki
    Abe, Hikaru
    Saitoh, Tadashi
    Sugimoto, Toshiyuki
    Takahashi, Tatsuhisa
    Yanagida, Hirotaka
    Transactions of Japanese Society for Medical and Biological Engineering, 2022, 60 (01) : 25 - 31
  • [47] High-Speed Electrochemical Imaging
    Momotenko, Dmitry
    Byers, Joshua C.
    McKelvey, Kim
    Kang, Minkyung
    Unwin, Patrick R.
    ACS NANO, 2015, 9 (09) : 8942 - 8952
  • [48] An accurate temperature field reconstruction method using schlieren imaging and optical flow for high-speed flow fields
    Wu, Jun
    Zhang, Zhen
    Zhu, Yuheng
    Tang, Yuanhong
    Guo, Runxia
    Chen, Jiusheng
    Xing, Zhiwei
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [49] Simultaneous imaging of flow and sound using high-speed parallel phase-shifting interferometry
    Ishikawa, Kenji
    Tanigawa, Risako
    Yatabe, Kohei
    Oikawa, Yasuhiro
    Onuma, Takashi
    Niwa, Hayato
    OPTICS LETTERS, 2018, 43 (05) : 991 - 994
  • [50] Ocular blood flow imaging and quantification
    Mujat, Mircea
    Zhao, Youbo
    Iftimia, Nicusor
    Ferguson, R. Daniel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)