ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

被引:15
|
作者
Silva, E. H. [1 ,2 ,3 ,4 ]
Knezevic, Z. [5 ]
Struelens, L. [1 ]
Covens, P. [2 ,3 ,6 ]
Ueno, S. [7 ]
Vanhavere, F. [1 ]
Buls, N. [2 ,3 ,8 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, B-2400 Mol, Belgium
[2] VUB, LABO, Laarbeeklaan 103, B-1090 Brussels, Belgium
[3] BEFY, Laarbeeklaan 103, B-1090 Brussels, Belgium
[4] Minist Educ Brazil, CAPES Fdn, BR-70040020 Brasilia, DF, Brazil
[5] Rudjer Boskovic Inst, Bijenicka 54, Zagreb 10000, Croatia
[6] Dept Radiat Protect VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium
[7] Chiyoda Technol Corp, Oarai Res Ctr, 3681 Naritacho, Oarai, Ibaraki 3111313, Japan
[8] UZ Brussel, Dept Radiol, Laarbeeklaan 101, B-1090 Brussels, Belgium
关键词
CONVERSION COEFFICIENTS; DOSE-EQUIVALENT; AIR KERMA; RADIATION; PHANTOM; PHOTON; H-P(3);
D O I
10.1093/rpd/ncw104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radio-photoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK center dot CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to H-p(3), although some improvements may be necessary.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 50 条
  • [21] THE PHOTON ENERGY-DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSIMETERS OVER THE RANGE 17 KEV TO 6.8 MEV
    CROFT, S
    WEAVER, DR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01): : 123 - 132
  • [22] The β-ray energy and angular response of the EYE-D™ eye-lens dosemeter
    Szumska, A.
    Budzanowski, M.
    Kopec, R.
    Olko, P.
    Ciupek, K.
    RADIATION MEASUREMENTS, 2013, 56 : 374 - 379
  • [23] Neutron dosimetry with TL albedo dosemeters at high energy accelerators
    Haninger, T.
    Fehrenbacher, G.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 361 - 363
  • [24] FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS
    Clairand, I.
    Ginjaume, M.
    Vanhavere, F.
    Carinou, E.
    Daures, J.
    Denoziere, M.
    Silva, E. H.
    Roig, M.
    Principi, S.
    Van Rycheghem, L.
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 21 - 26
  • [25] Application of a radiophotoluminescent glass dosimeter to nonreference condition dosimetry in the postal dose audit system
    Mizuno, Hideyuki
    Fukumura, Akifumi
    Fukahori, Mai
    Sakata, Suoh
    Yamashita, Wataru
    Takase, Nobuhiro
    Yajima, Kaori
    Katayose, Tetsurou
    Abe-Sakama, Kyoko
    Kusano, Yohsuke
    Shimbo, Munefumi
    Kanai, Tatsuaki
    MEDICAL PHYSICS, 2014, 41 (11)
  • [26] Feasibility study of radiophotoluminescent glass dosimeter for in vivo dosimetry in external photon beam radiotherapy
    Nazia Neelam Shehzadi
    Chul-Young Yi
    Ki-Hwan Kim
    Jaeuk Jang
    Ui-Jung Hwang
    Yunho Kim
    In Jung Kim
    Young Min Seong
    Journal of the Korean Physical Society, 2021, 78 : 523 - 534
  • [27] THE APPLICATION OF RADIOPHOTOLUMINESCENT GLASS TO GAMMA-DOSIMETRY IN MIXED N-GAMMA FIELDS
    CROFT, S
    WEAVER, DR
    HEFFER, PJH
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 67 - 70
  • [28] Feasibility study of radiophotoluminescent glass dosimeter for in vivo dosimetry in external photon beam radiotherapy
    Shehzadi, Nazia Neelam
    Yi, Chul-Young
    Kim, Ki-Hwan
    Jang, Jaeuk
    Hwang, Ui-Jung
    Kim, Yunho
    Kim, In Jung
    Seong, Young Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (06) : 523 - 534
  • [29] Correction of stopping power and LET quenching for radiophotoluminescent glass dosimetry in a therapeutic proton beam
    Chang, Weishan
    Koba, Yusuke
    Katayose, Tetsurou
    Yasui, Keisuke
    Omachi, Chihiro
    Hariu, Masatsugu
    Saitoh, Hidetoshi
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8869 - 8881
  • [30] Eye lens dosimetry in anesthesiology: a prospective study
    Bart Vaes
    Karel Van Keer
    Lara Struelens
    Werner Schoonjans
    Ivo Nijs
    Jan Vandevenne
    Sven Van Poucke
    Journal of Clinical Monitoring and Computing, 2017, 31 : 303 - 308