Investigation of the use of nano-refrigerants to enhance the performance of an ejector refrigeration system

被引:52
|
作者
Tashtoush, Bourhan M. [1 ]
Al-Nimr, Moh'd A. [1 ]
Khasawneh, Mohammad A. [1 ]
机构
[1] Jordan Univ Sci & Technol, Mech Engn, Irbid, Jordan
关键词
Ejector cooling cycle; Nano-refrigerant; Nanoparticle; Refrigeration; Flow boiling; Heat transfer; BOILING HEAT-TRANSFER; THERMAL-CONDUCTIVITY; NANOFLUIDS; DRIVEN; NANOREFRIGERANT; NANOPARTICLES; ENERGY; MODEL; CYCLE; GEOMETRIES;
D O I
10.1016/j.apenergy.2017.09.117
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, the performance of an ejector refrigeration system using nano-refrigerants is investigated. A new hypothesis is proposed for flow boiling modeling, where nanoparticles are assumed to not migrate to the vapor phase as phase changes occur continuously; this causes a significant increase in nanoparticle mass fraction for high vapor quality values. This assumption shows a reasonable correlation with previously published data for R113/CuO mixtures, where an average deviation of 9.24% was obtained. A parametric analysis is performed to investigate the variation in heat transfer coefficient (HTC) with temperature, nanoparticle type, size, and mass fraction. Finally, the effect of nanoparticles on the coefficient of performance (COP) of the ejector refrigeration cycle as a response to the augmented flow boiling HTC is investigated by simulating a 5-kW cooling refrigeration cycle. Considering the advantage of using nano-refrigerants, a higher quality vapor was attained at the evaporator exit, resulting in an increase in the enthalpy difference in the evaporator in the ejector cooling cycle. As a result, a lower mass flux inside the evaporator is required to attain the same cooling capacity. Improved refrigerant-side HTCs improve the overall HTCs of the evaporator, allowing the evaporator to operate at lower temperature differences and higher pressures, which consequently increases the cycle COPs. Furthermore, the refrigerant vapor quality increases at the evaporator exit, leading to an enhanced COP of the cycle. The augmentation in COP reached 24.7% and 12.61% for R134a with 2 wt.% CuO and Al2O3, respectively, whereas the vapor quality for the refrigerant leaving the evaporator increased from 0.7616 for the case of the pure refrigerant to 0.8212 for R134a/CuO 2 wt.% nano-refrigerant.
引用
收藏
页码:1446 / 1463
页数:18
相关论文
共 50 条
  • [41] Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement
    Sutthivirode, Kittiwoot
    Thongtip, Tongchana
    ENERGY REPORTS, 2022, 8 : 7263 - 7273
  • [42] Investigation of ejectors in refrigeration system: Optimum performance evaluation and ejector area ratios perspectives
    Chen, Jianyong
    Havtun, Hans
    Palm, Bjorn
    APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 182 - 191
  • [43] Experimental investigation of a two-phase ejector installed into the refrigeration system for performance enhancement
    Sutthivirode, Kittiwoot
    Thongtip, Tongchana
    ENERGY REPORTS, 2022, 8 : 7263 - 7273
  • [44] Impact of the mixing theories on the performance of ejector expansion refrigeration cycles for environmentally-friendly refrigerants
    Atmaca, Aye Ugurcan
    Erek, Aytunc
    Ekren, Orhan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 211 - 225
  • [45] Numerical investigation in effects of refrigerants' thermodynamic properties on performance of supersonic ejector
    Liang, Youcai
    Ye, Junhao
    Li, Hongyang
    Wang, Jianming
    Li, Zhengyong
    Lu, Jidong
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (13) : 2953 - 2966
  • [46] Experimental investigation of the COP improvement of a refrigeration cycle by use of an ejector
    Lucas, Christian
    Koehler, Juergen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06): : 1595 - 1603
  • [47] Performance investigation of a solar-driven ejector refrigeration cycle
    Saleh, B.
    Aly, Ayman A.
    Alsehli, M.
    Bassuoni, M. M.
    Elfasakhany, A.
    WORLD JOURNAL OF ENGINEERING, 2019, 16 (05) : 625 - 635
  • [48] The behaviour of a hybrid compressor and ejector refrigeration system with refrigerants 134a and 142b
    Hernández, JI
    Dorantes, RJ
    Best, R
    Estrada, CA
    APPLIED THERMAL ENGINEERING, 2004, 24 (13) : 1765 - 1783
  • [49] Evaluation on environment-friendly refrigerants with similar normal boiling points in ejector refrigeration system
    Wang, F.
    Shen, S. Q.
    Li, D. Y.
    HEAT AND MASS TRANSFER, 2015, 51 (07) : 965 - 972
  • [50] Evaluation on environment-friendly refrigerants with similar normal boiling points in ejector refrigeration system
    F. Wang
    S. Q. Shen
    D. Y. Li
    Heat and Mass Transfer, 2015, 51 : 965 - 972