IMPROVEMENT OF SHORT-TERM STABILITY OF PULSED OPTICALLY PUMPED RUBIDIUM ATOMIC CLOCK

被引:0
|
作者
Choi, I. H. [1 ]
Lee, S. B. [1 ]
Kwon, T. Y. [1 ]
Park, S. E. [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Taejon 305340, South Korea
来源
2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM | 2010年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a (87)Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2x10(-11) at 1 s has been measured and short term stability is improved by reducing the pulse sequence time with a real time control system.
引用
收藏
页码:432 / 433
页数:2
相关论文
共 50 条
  • [41] A Lamp-Pumped Rubidium Atomic Frequency Standard with a Short-Term Stability at the Level of 2 x 10-13τ-1/2
    Nie, Shuai
    Wang, Pengfei
    Qiu, Zijing
    Zhao, Feng
    Qi, Feng
    Ming, Gang
    Wang, Fang
    Niu, Xiumei
    Kang, Songbai
    Mei, Ganghua
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2019 PROCEEDINGS, VOL I, 2019, 562 : 556 - 563
  • [42] RESEARCH ON CHARACTERISTICS OF PULSED OPTICALLY PUMPED RUBIDIUM FREQUENCY STANDARD
    Deng, Jianliao
    Hu, Zhengfeng
    Li, Lin
    He, Huijuan
    PROCEEDINGS OF THE 7TH SYMPOSIUM FREQUENCY STANDARDS AND METROLOGY, 2009, : 348 - 352
  • [43] LaLI-POP: Lamp and Laser Integrated Pulsed-Optically Pumped Atomic Clock
    Huang, Michael
    Little, Arielle
    Camparo, James
    2022 JOINT CONFERENCE OF THE EUROPEAN FREQUENCY AND TIME FORUM AND IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (EFTF/IFCS), 2022,
  • [44] OPTICALLY PUMPED CESIUM ATOMIC-BEAM CLOCK
    CEREZ, P
    GIORDANO, V
    CANDELIER, V
    DECLERCQ, E
    ONDE ELECTRIQUE, 1986, 66 (06): : 72 - 75
  • [45] EXPERIMENTS ON A SEMICONDUCTOR-LASER PUMPED RUBIDIUM ATOMIC CLOCK
    HASHIMOTO, M
    OHTSU, M
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1987, 23 (04) : 446 - 451
  • [46] Optically pumped rubidium atomic magnetometer with elliptically polarized light
    Ding, Zhichao
    Yuan, Jie
    Wang, Zhiguo
    Lu, Guangfeng
    Luo, Hui
    OPTIK, 2016, 127 (13): : 5270 - 5273
  • [47] LABORATORY MODEL OF OPTICALLY PUMPED RUBIDIUM ATOMIC FREQUENCY STANDARD
    SAXENA, GM
    CHATTERJEE, A
    MATHUR, BS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1989, 27 (12) : 791 - 795
  • [48] Characterization of Short-term GNSS Satellite Clock Stability
    Griggs, Erin R.
    Kursinski, E. Robert
    Akos, Dennis M.
    PROCEEDINGS OF THE 46TH ANNUAL PRECISE TIME AND TIME INTERVAL SYSTEMS AND APPLICATIONS MEETING, 2014, : 170 - 175
  • [49] Operating Atomic Fountain Clock Using Robust DBR Laser: Short-Term Stability Analysis
    Lee, Sangmin
    Heo, Myoung-Sun
    Kwon, Taeg Yong
    Hong, Hyun-Gue
    Lee, Sang-Bum
    Hilton, Ashby Paul
    Luiten, Andre Nicholas
    Hartnett, John Gideon
    Park, Sang Eon
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (06) : 1349 - 1354
  • [50] Realization of a pulsed optically pumped Rb clock with a frequency stability below 10-15
    Gozzelino, Michele
    Micalizio, Salvatore
    Calosso, Claudio E.
    Belfi, Jacopo
    Sapia, Adalberto
    Gioia, Marina
    Levi, Filippo
    SCIENTIFIC REPORTS, 2023, 13 (01):