Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging

被引:17
|
作者
Thanh Phuoc Nguyen [1 ]
Van Tu Nguyen [2 ]
Mondal, Sudip [3 ]
Van Hiep Pham [2 ]
Dinh Dat Vu [2 ]
Kim, Byung-Gak [4 ]
Oh, Junghwan [2 ,3 ]
机构
[1] Cao Thang Tech Coll, Dept Mechatron, Ho Chi Minh City 700000, Vietnam
[2] Pukyong Natl Univ, Interdisciplinary Program Biomed Mech & Elect Eng, Busan 48513, South Korea
[3] Pukyong Natl Univ, Ctr Marine Integrated Biomed Technol, Busan 48513, South Korea
[4] Pukyong Natl Univ, Coll Future Convergence, Busan 48513, South Korea
关键词
ultrasound; photoacoustic imaging; photoacoustic microscopy; biomedical imaging; multifocal point transducer; IN-VIVO; HIGH-FREQUENCY; ULTRASOUND; TOMOGRAPHY; CONTRAST; DESIGN; FABRICATION; SYSTEM;
D O I
10.3390/s20072020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a photoacoustic microscopy (PAM) system based on a multifocal point (MFP) transducer was fabricated to produce a large depth-of-field tissue image. The customized MFP transducer has seven focal points, distributed along with the transducer's axis, fabricated by separate spherically-focused surfaces. These surfaces generate distinct focal zones that are overlapped to extend the depth-of-field. This design allows extending the focal zone of 10 mm for the 11 MHz MFP transducer, which is a great improvement over the 0.48 mm focal zone of the 11 MHz single focal point (SFP) transducer. The PAM image penetration depths of a chicken-hemoglobin phantom using SFP and MFP transducers were measured as 5 mm and 8 mm, respectively. The significant increase in the PAM image-based penetration depth of the chicken-hemoglobin phantom was a result of using the customized MFP transducer.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Deep learning-enhanced microscopy with extended depth-of-field
    Yide Zhang
    Light: Science & Applications, 12
  • [22] Extending the depth-of-field of imaging systems with a scattering diffuser
    Meihua Liao
    Dajiang Lu
    Giancarlo Pedrini
    Wolfgang Osten
    Guohai Situ
    Wenqi He
    Xiang Peng
    Scientific Reports, 9
  • [23] Synthetic Bessel light needle for extended depth-of-field microscopy
    Yang, Jiamiao
    Gong, Lei
    Shen, Yuecheng
    Wang, Lihong, V
    APPLIED PHYSICS LETTERS, 2018, 113 (18)
  • [24] Depth-of-Field and Coded Aperture Imaging on XSlit Lens
    Ye, Jinwei
    Ji, Yu
    Yang, Wei
    Yu, Jingyi
    COMPUTER VISION - ECCV 2014, PT III, 2014, 8691 : 753 - 766
  • [25] Studies on depth-of-field effects in microscopy supported by numerical simulations
    Overby, DR
    Johnson, M
    JOURNAL OF MICROSCOPY-OXFORD, 2005, 220 : 176 - 189
  • [26] DROP SIZING AND DEPTH-OF-FIELD CORRECTION IN TV IMAGING
    KIM, KS
    KIM, SS
    ATOMIZATION AND SPRAYS, 1994, 4 (01) : 65 - 78
  • [27] Extending the depth-of-field of imaging systems with a scattering diffuser
    Liao, Meihua
    Lu, Dajiang
    Pedrini, Giancarlo
    Osten, Wolfgang
    Situ, Guohai
    He, Wenqi
    Peng, Xiang
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [28] Large Depth-of-Field Integral Microscopy by Use of a Liquid Lens
    Llavador, Anabel
    Scrofani, Gabriele
    Saavedra, Genaro
    Martinez-Corral, Manuel
    SENSORS, 2018, 18 (10)
  • [29] Expansion of Depth-of-Field of Scattering Imaging Based on DenseNet
    Lin Zhaosu
    Wang Yangyundou
    Wang Hao
    Hu Chuanfei
    Gu Min
    Yang Hui
    ACTA OPTICA SINICA, 2022, 42 (04)
  • [30] Information optimized extended depth-of-field imaging systems
    van der Gracht, J
    Euliss, GW
    VISUAL INFORMATION PROCESSING X, 2001, 4388 : 103 - 112