An Open-Loop Positioning Method for Reduction of Influence of Nonlinearities in Piezoelectric Actuator

被引:4
|
作者
Henmi, Nobuhiko [1 ]
机构
[1] Shinshu Univ, Nagano 3808553, Japan
关键词
Piezoelectric Actuator; Open-Loop Drive; Precise Positioning; Voltage Drive; Creep; Hysteresis;
D O I
10.1299/jamdsm.5.70
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A unique driving method of piezoelectric actuator to reduce influences of hysteresis and creep is represented in the paper. It is for point-to-point (PTP) open-loop positioning. In the method, when an object is stepwise positioned using the piezoelectric actuator, the input voltage to the actuator is raised up to maximum value and pulled down to 0V sinusoidally in order to initialize the actuator condition, and then it is returned to a constant starting point at the beginning of every step. Finally it is raised up to appropriate step height with some overshoot. Both influences of hysteresis and creep characteristics are reduced drastically using the method. Stepwise positioning of 2 mu m step height with 0.2 mu m accuracy is realized using the basic method. For nano-meter order positioning accuracy, creep behavior of the actuator is serious problem. It is found that multi-cycle large sinusoidal drive which is called initializing drive can reduce creep motion significantly. Eventually, less than 5nm accuracy for 20nm stepwise PTP positioning is realized.
引用
收藏
页码:70 / 79
页数:10
相关论文
共 50 条
  • [21] The influence of vergence adaptation on open-loop vergence dynamics
    Satgunam, PremNandhini
    Gowrisankaran, Sowjanya
    Fogt, Nick
    VISION RESEARCH, 2009, 49 (14) : 1795 - 1804
  • [22] A novel Approach to Calibrate Open-loop Amplifier Nonlinearities through Piecewise linear Interpolation
    Gong Yuehong
    Luo Min
    Yu Mingyan
    Ma Jianguo
    Mao Ze
    2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT-2012), 2012, : 1431 - 1433
  • [23] Open-Loop Drug Delivery Strategy to the Cochlea using a Permanent Magnetic Actuator
    Amokrane, Walid
    Belharet, Karim
    Souissi, Mouna
    Grayeli, Alexis Bozorg
    Ferreira, Antoine
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2018, : 1519 - 1524
  • [24] An algebraic method for analyzing open-loop dynamic systems
    Zhou, W
    Jeffrey, DJ
    Reid, GJ
    COMPUTATIONAL SCIENCE - ICCS 2005, PT 3, 2005, 3516 : 586 - 593
  • [25] Reduction of open-loop low frequency beam motion at the APS
    Decker, G
    Kang, YG
    Kim, S
    Mangra, D
    Merl, R
    McGhee, D
    Sharma, S
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 303 - 305
  • [26] Comparison Study between Open-Loop and Closed-Loop Identification for Industrial Hydraulics Actuator System
    Ali, Nur Husnina Mohamad
    Ghazali, Rozaimi
    Jaafar, Hazriq Izzuan
    Ghani, Muhammad Fadli
    Soon, Chong Chee
    Has, Zulfatman
    INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND ROBOTICS RESEARCH, 2024, 13 (05): : 516 - 521
  • [27] Simultaneous compensation of hysteresis and creep in a single piezoelectric actuator by open-loop control for quasi-static space active optics applications
    Wang, Xuan
    Pommier-Budinger, Valerie
    Reysset, Aurelien
    Gourinat, Yves
    CONTROL ENGINEERING PRACTICE, 2014, 33 : 48 - 62
  • [28] Real-time calibration of open-loop piezoelectric actuators for interferometric applications
    Bruno L.
    Maletta C.
    International Journal of Mechanics and Materials in Design, 2008, 4 (2) : 97 - 103
  • [29] Two methods to eliminate the elastic influence of open-loop mechanism
    Jixie Kexue Yu Jishu, 5 (774-776, 794):
  • [30] Control of open-loop neutrally stable systems subject to actuator saturation and external disturbances
    Wang, Xu
    Saberi, Ali
    Grip, Havard Fjaer
    Stoorvogel, Anton A.
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2013, 23 (02) : 229 - 240