Persistent residual shunts after atrial septal defect closure with the Amplatzer septal occluder

被引:0
|
作者
Hiremath, Gurumurthy [1 ]
March, S. Kimara [2 ]
Bass, John L. [1 ]
机构
[1] Univ Minnesota, Masonic Childrens Hosp, Dept Pediat, Div Pediat Cardiol, 2450 Riverside Ave, Minneapolis, MN 55454 USA
[2] Univ Minnesota Phys, Dept Cardiol, Minneapolis, MN USA
关键词
Atrial septal defect; Residual shunt; Amplatzer septal occluder; TRANSCATHETER CLOSURE; DEVICE CLOSURE; EROSION; RISK;
D O I
10.1016/j.ppedcard.2021.101462
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of atrial septal defects (ASD) is a common procedure. Amplatzer Septal Occluder (ASO) was the first device to receive FDA approval for this procedure in December 2001 and is commonly used for this indication. Persistent residual shunts are infrequent following ASD device closure with the ASO device. We report two adult patients with persistent and remarkably similar residual shunts that occurred anteriorly between the discs of the device as it splayed around the aorta. We speculate that oversizing ASO devices could lead to a residual shunt between the discs.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Transcatheter closure of atrial septal defect using amplatzer septal occluder in Chinese adults
    Lee, CH
    Kwok, OH
    Fan, K
    Chau, E
    Yip, A
    Chow, WH
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (03) : 373 - 377
  • [22] Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder
    Song, Jinyoung
    Lee, Sang Yoon
    Baek, Jae Sook
    Shim, Woo Seub
    Choi, Eun Young
    YONSEI MEDICAL JOURNAL, 2013, 54 (05) : 1104 - 1109
  • [23] Thrombus Formation during Percutaneous Closure of an Atrial Septal Defect with an Amplatzer Septal Occluder
    Yorgun, Hikmet
    Canpolat, Ugur
    Kaya, Ergun Baris
    Aytemir, Kudret
    Oto, Ali
    TEXAS HEART INSTITUTE JOURNAL, 2011, 38 (04) : 427 - 430
  • [24] Congenital ventricular septal defect closure with Amplatzer septal occluder
    Chessa, M
    Butera, G
    Bini, RM
    Pomè, G
    Giamberti, A
    Drago, M
    Rosti, L
    Carminati, M
    EUROPEAN HEART JOURNAL, 2001, 22 : 417 - 417
  • [25] Residual atrial septal defect after percutaneous closure with an Amplatzer device
    Casquero, Elena
    Pinon, Miguel
    Paredes, Emilio
    Casais, Rocio
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (02) : 489 - 489
  • [26] Atrial septal defect closure in adult patients with the amplatzer ASD occluder
    Slevert, H
    Krumsdorf, U
    Horvath, K
    Keppeler, P
    Schräder, R
    Zeplin, H
    Spies, H
    Fach, A
    Scherer, D
    Ensslen, R
    Merle, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 497A - 497A
  • [27] Huge thrombus formation 1 year after percutaneous closure of an atrial septal defect with an Amplatzer septal occluder
    Uysal, Fahrettin
    Bostan, Ozlem Mehtap
    Signak, Isik Senkaya
    Gunes, Mustafa
    Cil, Ergun
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2016, 16 (01): : 63 - 64
  • [28] Impact of right ventricular size on ECG after percutaneous closure of atrial septal defect with Amplatzer Septal Occluder
    Di Bernardo, S
    Berger, F
    Fasnacht, M
    Bauersfeld, U
    SWISS MEDICAL WEEKLY, 2005, 135 (43-44) : 647 - 651
  • [29] Comparison of results of closure of secundum atrial septal defect by surgery versus amplatzer septal occluder
    Cowley, CG
    Lloyd, TR
    Bove, EL
    Gaffney, D
    Dietrich, M
    Rocchini, AP
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (05): : 589 - +
  • [30] 'DEVICECTOMY' FOLLOWING SEVERE NICKEL ALLERGY AFTER TRANSCATHETER CLOSURE OF AN ATRIAL SEPTAL DEFECT WITH AMPLATZER SEPTAL OCCLUDER
    Fernandes, P.
    Michielon, G.
    Fraisse, A.
    HEART, 2018, 104 : A6 - A7