A Voltammetric Sensor Based on MgFe2O4 Decorated on Reduced Graphene Oxide-modified Electrode for Sensitive and Simultaneous Determination of Catechol and Hydroquinone

被引:21
|
作者
Ognjanovic, Milos [1 ]
Stankovic, Dalibor M. [1 ,2 ]
Fabian, Martin [1 ,3 ]
Vukadinovic, Aleksandar [1 ]
Prijovic, Zeljko [1 ]
Dojcinovic, Biljana [4 ]
Antic, Bratislav [1 ]
机构
[1] Univ Belgrade, Vinca Inst Nucl Sci, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia
[2] Univ Belgrade, Fac Chem, Innovat Ctr, Studentski Trg 12-16, Belgrade 11000, Serbia
[3] Slovak Acad Sci, Inst Geotech, Watsonova 45, Kosice, Slovakia
[4] Univ Belgrade, Inst Chem Technol & Met, Studentski Trg 12-16, Belgrade 11000, Serbia
关键词
MgFe@RGO nanocomposite; Magnesium ferrite; Dihydroxibenzenes; Differential pulse voltammetry; CARBON-PASTE ELECTRODE; GOLD NANOPARTICLES; ELECTROCHEMICAL PREPARATION; DIHYDROXYBENZENE ISOMERS; DOPED GRAPHENE; GREEN APPROACH; PERFORMANCE; REDUCTION; COMPOSITE; TITANIUM;
D O I
10.1002/elan.201800357
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work facile one step synthesis of magnesium ferrite (MgFe2O4) nanoparticles decorated on reduced graphene oxide (MgFe@RGO) using a microwave assisted hydrothermal procedure is reported. The synthesized material was characterized with help of several techniques and applied for the modification of glassy carbon electrode. Such prepared electrode was utilized for successive simultaneous detection of structurally similar compounds, 1,2- and 1,4-dihydroxibenzenes (catechol (CC) and hydroquinone (HQ)), using differential pulse voltammetry technique. It was found that oxidation current increases linearly with the concentrations of both investigated compounds. Detection limits for both species are <= 0.31 mu M. The best analytical response in the presence of both CC and HQ, taking into account peak shape and peak current, was obtained at pH 5.6 utilizing acetate buffer solution. The often-presented species in the surface waters as well as gallic acid and caffeine do not interfere with determination of CC and HQ, while ascorbic acid shows high interference. The method is successfully applied for detection of catechol and hydroquinone in real samples analyses.
引用
收藏
页码:2620 / 2627
页数:8
相关论文
共 50 条
  • [1] A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) : 209 - 213
  • [2] A promising photoelectrochemical sensor based on a ZnO particle decorated N-doped reduced graphene oxide modified electrode for simultaneous determination of catechol and hydroquinone
    Vilian, A. T. Ezhil
    Rajkumar, Muniyandi
    Chen, Shen-Ming
    Hu, Chi-Chang
    Piraman, Shakkthivel
    RSC ADVANCES, 2014, 4 (89): : 48522 - 48534
  • [3] Simultaneous Voltammetric Determination of Uric Acid, Xanthine, and Hypoxanthine Using CoFe2O4/Reduced Graphene Oxide-Modified Electrode
    Nguyen Thi Vuong Hoan
    Nguyen Ngoc Minh
    Nguyen Thi Hong Trang
    Le Thi Thanh Thuy
    Cao Van Hoang
    Tran Xuan Mau
    Ho Xuan Anh Vu
    Phan Thi Kim Thu
    Nguyen Hai Phong
    Dinh Quang Khieu
    JOURNAL OF NANOMATERIALS, 2020, 2020
  • [4] polycalconcarboxylic acid/electrochemically reduced graphene oxide-modified glassy carbon electrode-based voltammetric sensor for the simultaneous determination of dopamine and tyrosine
    Swathy, S.
    Kodakat, Keerthi
    Kumar, K. Girish
    IONICS, 2024, 30 (06) : 3521 - 3539
  • [5] A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    He, Jiahong
    Qiu, Ri
    Li, Wenpo
    Xing, Shaohua
    Song, Zhongrong
    Li, Qiang
    Zhang, Shengtao
    ANALYTICAL METHODS, 2014, 6 (16) : 6494 - 6503
  • [6] A voltammetric sensor based on electrochemically reduced graphene modified electrode for sensitive determination of midecamycin
    Xi, Xia
    Ming, Liang
    ANALYTICAL METHODS, 2012, 4 (09) : 3013 - 3018
  • [7] A graphene oxide-mesoporous MnO2 nanocomposite modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of hydroquinone and catechol
    Gan, Tian
    Sun, Junyong
    Huang, Kejing
    Song, Li
    Li, Youmei
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 412 - 418
  • [8] A voltammetric sensor based on electrochemically activated glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    Kong, Yong
    Chen, Xiaohui
    Yao, Chao
    Ma, Mengjie
    Chen, Zhidong
    ANALYTICAL METHODS, 2011, 3 (09) : 2121 - 2126
  • [9] High sensitive simultaneous determination of hydroquinone and catechol based on graphene/BMIMPF6 nanocomposite modified electrode
    Liu, Zhimin
    Wang, Zhenling
    Cao, Yanyan
    Jing, Yanfeng
    Liu, Yanli
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02): : 540 - 546
  • [10] A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode
    Nikhil, S.
    Karthika, A.
    Suresh, P.
    Suganthi, A.
    Rajarajan, M.
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (07) : 2148 - 2159