Accuracy of Quantitative Computed Tomography Bone Mineral Density Measurements in Mandibles: A Cadaveric Study

被引:4
|
作者
Miguel-Sanchez, Alfonso [1 ]
Vilaplana-Vivo, Jaime [1 ]
Vilaplana-Vivo, Carlos [1 ]
Angel Vilaplana-Gomez, Juan [1 ]
Camacho-Alonso, Fabio [2 ]
机构
[1] Univ Murcia, Oral Surg, E-30001 Murcia, Spain
[2] Univ Murcia, Oral Med, E-30001 Murcia, Spain
关键词
bone mineral density; calibration bone phantom; computed tomography; BIOMECHANICAL ASPECTS; IMPLANT STABILITY; TITANIUM IMPLANTS; TRABECULAR BONE; CT; SITES; ASSESSMENTS; NAVIGATION; INSERTION; QUALITY;
D O I
10.1111/cid.12168
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim was to investigate the accuracy of quantitative computed tomography bone mineral density (BMD) measurements in mandibles, comparing measured BMD with calibrated BMD. Materials and MethodsSeventy mandibles from adult cadavers were used. Twenty tomographic cuts were made in each mandible. In each tomographic cut, a region of interest was located, and the bone density was measured in Hounsfield unit (HU). A polymethyl methacrylate phantom containing four inserts of different predetermined densities (hydroxyapatite 100, 200, 500, and 700mg/cm(3)) was used to calculate calibrated bone density. Correlation between measured and calibrated bone densities was calculated. ResultsMean total correlation between measured and calibrated BMD in the 20 sagittal tomography cuts showed almost perfect positive correlation (r=0.998, p<.001). However, when average BMD measurements in HU were compared, the measured total BMD (in the 20 sagittal tomography cuts studied) was 54.99421.59, whereas the total calibrated BMD was 49.28 +/- 364.95, with statistically significant difference (p=.001). ConclusionsThere are discrepancies between measured and calibrated BMD; in this sense, a calibrated bone phantom with a predetermined mineral density should be used to determine the exact BMD before dental implants surgery.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [41] Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography in Normal Cats
    Cheon, Haengbok
    Choi, Wooshin
    Lee, Youngjae
    Lee, Donghoon
    Kim, Juhyung
    Kang, Ji-Houn
    Na, Kijeong
    Chang, Jinhwa
    Chang, Dongwoo
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2012, 74 (11): : 1461 - 1467
  • [42] Quantitative computed tomography of bone mineral density in the mandible -: imaging the topographical distribution of bone mineral density by automatic segmentation of jaw structures
    Hothan, T
    Hidajat, N
    Nelson, K
    Felix, R
    Mäurer, J
    RADIOLOGE, 2001, 41 (06): : 497 - +
  • [43] AGE-RELATED CHANGES OF BONE MINERAL DENSITY IN MANDIBLE BY QUANTITATIVE COMPUTED TOMOGRAPHY
    Du, X.
    Jiao, J.
    Cheng, X.
    Wang, L.
    Li, K.
    Liu, H.
    Wang, C.
    Arena, C.
    Zhurakivska, K.
    Guglielmi, G.
    Lo Muzio, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (04): : 997 - 1003
  • [44] Volumetric bone mineral density using peripheral quantitative computed tomography in Japanese women
    Hasegawa, Y
    Kushida, K
    Yamazaki, K
    Inoue, T
    OSTEOPOROSIS INTERNATIONAL, 1997, 7 (03) : 195 - 199
  • [45] Quantitative computed tomography precision and accuracy for long-term follow-up of bone mineral density measurements - A five-year in vitro assessment
    Braillon, PM
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (03) : 259 - 266
  • [46] Bone mineral density measurements in postmortem computed tomography: An open-source approach
    Hansen, Kasper
    Vinther, Dennis
    Boel, Lene Warner Thorup
    Agacan, Guelislam
    Thygesen, Jesper
    Uhrenholt, Lars
    Lauridsen, Henrik
    FORENSIC IMAGING, 2024, 37
  • [47] Use of computed tomography for assessing bone mineral density
    Schreiber, Joseph J.
    Anderson, Paul A.
    Hsu, Wellington K.
    NEUROSURGICAL FOCUS, 2014, 37 (01)
  • [48] ASSESSMENT OF BONE MINERAL DENSITY: A COMPARATIVE PILOT STUDY WITH PHANTOM LESS QUANTITATIVE COMPUTED TOMOGRAPHY (QCT) AND QUANTITATIVE ULTRASOUND (QUS)
    David, L. R.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S41 - S41
  • [49] Accuracy of Volumetric Bone Mineral Density Measurement in Weight Bearing, Cone Beam Computed Tomography
    Waungana, Tadiwa H.
    Qiu, Keven
    Tse, Justin J.
    Anderson, Donald D.
    Emery, Carolyn A.
    Boyd, Steven K.
    Manske, Sarah L.
    JOURNAL OF CLINICAL DENSITOMETRY, 2024, 27 (03)
  • [50] Computed Tomography Evaluation of Human Mandibles with Regard to Layer Thickness and Bone Density of the Cortical Bone
    Markwardt, J.
    Meissner, H.
    Weber, A.
    Laniado, M.
    Reitemeier, B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (01): : 40 - 47