On evaluating x-ray imaging crystals with synchrotron radiation

被引:7
|
作者
Pereira, N. R. [1 ]
Macrander, A. T. [2 ]
Stoeckl, C. [3 ]
Baronova, E. O. [4 ]
机构
[1] Ecopulse Inc, 7844 Vervain Ct, Springfield, VA 22152 USA
[2] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[3] Univ Rochester, Lab Laser Energet, Rochester, NY 14623 USA
[4] Kurchatov Inst, Moscow 123098, Russia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
QUARTZ CRYSTALS; RESOLUTION;
D O I
10.1063/1.5045569
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Bent crystals used in diagnostics of plasmas combine x-rays diffracted from across the crystal. Therefore imperfections in the resulting 1-D spectrum or 2-D image are not the best way to find out why one particular crystal may differ in its performance from another and what, if anything, to do about it. Instead, here we want to measure the diffraction locally, with the necessary resolution. Nominally monochromatic and unidirectional radiation from the synchrotron's standard x-ray optics proved to be insufficient for the purpose. Here much better radiation comes from the x-ray topography setup at the x-ray optics testing beamline 1-BM at the Advanced Photon Source, thanks to a specially designed quartz conditioning crystal. Some worrisome features in a bent crystal's diffraction have thereby disappeared, while minor fabrication flaws remain highly visible. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] X-RAY OPTICS FOR SYNCHROTRON RADIATION
    MALGRANGE, C
    ACTA PHYSICA POLONICA A, 1992, 82 (01) : 13 - 32
  • [22] X-RAY INTERFEROMETRY WITH SYNCHROTRON RADIATION
    BONSE, U
    MATERLIK, G
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S232 - S232
  • [23] X-RAY OPTICS FOR SYNCHROTRON RADIATION
    FREUND, AK
    SYNCHROTRON RADIATION IN STRUCTURAL BIOLOGY, 1989, 51 : 255 - 292
  • [24] X-ray microscopy with synchrotron radiation
    Chris Jacobsen
    Janos Kirz
    Nature Structural Biology, 1998, 5 : 650 - 653
  • [25] X-ray microscopy with synchrotron radiation
    Jacobsen, C
    Kirz, J
    NATURE STRUCTURAL BIOLOGY, 1998, 5 (Suppl 8) : 650 - 653
  • [26] Viewpoint on `Phase objects in synchrotron radiation hard x-ray imaging'
    Margaritondo, G.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (11)
  • [27] The imaging of failure in structural materials by synchrotron radiation X-ray microtomography
    Wu, S. C.
    Xiao, T. Q.
    Withers, P. J.
    ENGINEERING FRACTURE MECHANICS, 2017, 182 : 127 - 156
  • [28] Diffraction-enhanced imaging with synchrotron radiation X-ray for liver
    Peng, Yi-Feng
    Chen, Shaoliang
    Tang, Guangyu
    Chen, Yuesheng
    Shen, Renjie
    Chenb, Aiping
    Zhu, Pei-Ping
    Huang, Wan-Xia
    Yuan, Qing-Xi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (02) : 97 - 100
  • [29] CMOS imaging detectors as x-ray detectors for synchrotron radiation experiments
    Yagi, N
    Yamamoto, M
    Uesugi, K
    Inoue, K
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 885 - 888
  • [30] Imaging soft X-ray microscope at Rits Synchrotron Radiation Center
    Hirai, A
    Takemoto, K
    Nishino, K
    Watanabe, N
    Anderson, E
    Attwood, D
    Kern, D
    Hettwer, M
    Rudolph, D
    Aoki, S
    Nakayama, Y
    Kihara, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1102 - 1104