TOTAL KNEE ARTHROPLASTY WITH A MOBILE TIBIAL BEARING. MEDIUM-TERM FOLLOW-UP RESULTS

被引:1
|
作者
Betoni Guglielmetti, Luiz Gabriel [1 ]
Couto, Rodrigo do Carmo [1 ]
Arbix de Camargo, Osmar Pedro [1 ]
Severino, Nilson Roberto [1 ]
Leite Cury, Ricardo de Paula [1 ]
de Oliveira, Victor Marques [1 ]
Aihara, Tatsuo [1 ]
Avakian, Roger [1 ]
机构
[1] Fac Ciencias Med Santa Casa Sao Paulo, Dept Orthoped & Traumatol, Sao Paulo, Brazil
来源
ACTA ORTOPEDICA BRASILEIRA | 2010年 / 18卷 / 06期
关键词
Knee arthroplasty knee replacement; Knee prosthesis; Treatment outcome Outcome assessment (health care); Postoperative complications; FIXED-BEARING; ROTATING-PLATFORM; REPLACEMENT; PROSTHESIS; KINEMATICS; DESIGN; DISLOCATION; FRACTURES; OUTCOMES; SYSTEM;
D O I
10.1590/S1413-78522010000600001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Evaluation of mid term follow up results of the application of a total knee replacement with a mobile tibial bearing design Methods Ninety six patients (107 knees) were submitted to total knee Arthroplasty performed with a model of prosthesis with rotating mobility in the tibial component The patients were evaluated after a mean follow up of 52 7 months standard deviation 21 94 (minimum 24 months and maximum 120 months) through the Knee Society Clinical Rating System (KSCRS) with a mean outcome of 78 22 points Results The complications that occurred immediately after or during the surgery included one wound dehiscence with spontaneous healing two patellar fractures one fracture of the medial condyle of the femur three peroneal nerve impairments and one sympathetic reflex nervous distrophy Subsequent complications were one patellar fracture one distal fracture of the femur four aseptic loosenings and four deep joint infections which required arthroplastic revisions Conclusion With the exception of the cases requiring arthroplastic revision due to septic or aseptic loosening the authors conclude that the clinical and functional results obtained with Total Knee Replacement with a mobile bearing component in a mid term follow up were good
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [31] Rotaglide Total Knee Arthroplasty: A Long-Term Follow-up Study
    Metsovitis, Stergios R.
    Ploumis, Avraam L.
    Chantzidis, Paraskevas T.
    Terzidis, Ioannis P.
    Christodoulou, Anastasios G.
    Dimitriou, Christos G.
    Tsakonas, Athanasios C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (09): : 878 - 884
  • [32] Long-term Follow-up of Patellar Nonresurfacing in Total Knee Arthroplasty
    Choi, Young
    Koo, Junsung
    Moon, Sang Won
    Yang, Younghoon
    Son, Junghwan
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (01) : 49 - 54
  • [33] Transurethral balloon laser prostatectomy in the canine: Medium-term, follow-up results
    Suzuki, T
    Kurokawa, K
    Suzuki, K
    Yamanaka, H
    LASERS IN SURGERY AND MEDICINE, 1995, 17 (04) : 358 - 363
  • [34] Linear accelerator radiosurgery for vestibular schwannomas: Results of medium-term follow-up
    Ellenbogen, Jonathan R.
    Waqar, Mueez
    Kinshuck, Andrew J.
    Jenkinson, Michael D.
    Lesser, Tristram H. J.
    Husband, David
    Javadpour, Mohsen
    BRITISH JOURNAL OF NEUROSURGERY, 2015, 29 (05) : 678 - 684
  • [35] INTRARTICULAR TREATMENT OF OSTEOARTROPATY KNEE WITH POLYNUCLEOTIDES: A PILOT STUDY WITH MEDIUM-TERM FOLLOW-UP
    Saggini, R.
    Di Stefano, A.
    Cavezza, T.
    Saladino, G.
    Bellomo, R. G.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2013, 27 (02): : 543 - 549
  • [36] The effect of tibial slope angle on clinical and functional results after mobile bearing total knee arthroplasty
    Adiyeke, Levent
    Kafadar, Adnan Behcet
    Erdogan, Ozgur
    Gunduz, Cagdas Deniz
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2022, 29 (01)
  • [37] Bilateral condyle fracture of tibial insert in mobile bearing total knee arthroplasty
    Yoon, Jung-Ro
    Jeong, Hyeon-Il
    Oh, Kwang-Jun
    Yang, Jae-Hyuk
    KNEE, 2014, 21 (01): : 318 - 321
  • [38] Long-term follow-up of the GSB II total knee used in primary total knee arthroplasty
    Sprenger, TR
    Doerzbacher, JF
    JOURNAL OF ARTHROPLASTY, 2002, 17 (02): : 176 - 183
  • [39] Long-term results of total knee arthroplasty in haemophilic patients: an 18-year follow-up
    Lukas Ernstbrunner
    Andreas Hingsammer
    Sabrina Catanzaro
    Reto Sutter
    Brigit Brand
    Karl Wieser
    Sandro F. Fucentese
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 3431 - 3438
  • [40] Long-term results of total knee arthroplasty in haemophilic patients: an 18-year follow-up
    Ernstbrunner, Lukas
    Hingsammer, Andreas
    Catanzaro, Sabrina
    Sutter, Reto
    Brand, Brigit
    Wieser, Karl
    Fucentese, Sandro F.