Experimental Study on Rotational Behavior of Bolted Glulam Beam-to-column Connections Reinforced Using CFRP Sheets

被引:0
|
作者
Wang, Ming-Qian [1 ]
Song, Xiao-Bin [1 ]
Gu, Xiang-Lin [1 ]
Wu, Ya-Jie [1 ]
Luo, Lie [1 ]
机构
[1] Tongji Univ, Dept Bldg Engn, Shanghai, Peoples R China
关键词
Glulam; Bolted Beam-to-column Connection; Slotted-in Steel Plate; CFRP sheet; Monotonic Loading Test; Moment Resistance; Deformability;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, three groups of bolted glulam beam-to-column connections with slotted-in steel plates (in total 11 full-scale specimens) were tested under monotonic loading to investigate the rotational behavior of such connections with the use of carbon fiber reinforcing polymer sheets wrapping. The influence of CFRP sheet layers on the performance improvement of the connections was also quantified. The test results indicated that the maximum moments were increased by 14% and 18% for reinforced connections wrapped using 1 and 2 layers of CFRP sheets, respectively; furthermore, the deformability ratios evaluated based on the rotation angles corresponding to the yielding and maximum moments, respectively, were increased by 78% and 72%. It was also found that the variation of the maximum moment of reinforced connections can be reduced with increased layers of CFRP sheets.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 50 条
  • [31] Analytical investigation and parametric study on the fire behavior of glulam bolted beam-to-column connections based on the quasi-non-linear fracture mechanics model
    Luo, Jing
    Li, Zheng
    He, Minjuan
    Gan, Zhaozhuo
    Wang, Xijun
    FIRE SAFETY JOURNAL, 2022, 133
  • [32] Experimental study on beam-to-column clip angle bolted connection
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2019, 141 : 540 - 553
  • [33] Experimental Evaluation of Steel Beam Bolted to Reinforced Concrete Column Connections
    Li, Xian
    Xiao, Yan
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 311 - 319
  • [34] Experimental evaluation of steel beam bolted to reinforced concrete column connections
    Li, Xian
    Xiao, Yan
    Key Engineering Materials, 2009, 400-402 : 311 - 319
  • [35] Rotational behavior of bolted post-to-beam glulam connections with friction damped knee brace
    Zhang, Jing
    Liu, Dongying
    Liu, Zhifang
    Mo, Liucheng
    Xiang, Xinmei
    Wang, Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [36] Ultimate behaviour of bolted beam-to-column connections in large rotations
    Francavilla, Antonella B.
    Latour, Massimo
    Tan, P.J.
    Rizzano, Gianvittorio
    ce/papers, 2023, 6 (3-4) : 2201 - 2205
  • [37] Experimental analysis of innovative dissipative bolted double split tee beam-to-column connections
    Latour, Massimo
    Piluso, Vincenzo
    Rizzano, Gianvittorio
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2011, 4 (02): : 53 - 64
  • [38] A FE parametric study of RWS beam-to-column bolted connections with cellular beams
    Tsavdaridis, Konstantinos Daniel
    Papadopoulos, Theodore
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 116 : 92 - 113
  • [39] Ultimate behaviour of bolted beam-to-column connections in large rotations
    Francavilla, Antonella B.
    Latour, Massimo
    Tan, P. J.
    Rizzano, Gianvittorio
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 208
  • [40] ANALYSIS OF BEAM-TO-COLUMN BOLTED FLUSH END PLATE CONNECTIONS
    Foces, Antonio
    Garrido, Jose Antonio
    Moreno, Alicia
    REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2007, 23 (01): : 35 - 53