Hemovigilance and patient safety: analysis of immediate transfusion reactions in elderly

被引:1
|
作者
dos Santos Sobral, Paola Almeida [1 ]
Donato Gottems, Leila Bernarda [2 ]
Santana, Levy Aniceto [2 ]
机构
[1] Secretaria Estado Saude Dist Fed, Brasilia, DF, Brazil
[2] Escola Super Ciencias Saude, Brasilia, DF, Brazil
关键词
Transfusion Reaction; Blood Safety; Patient Safety; Blood ComponentTransfusion; Blood Component Transfusion; Quality of Health Care; Aged;
D O I
10.1590/0034-7167-2019-0735
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To identify immediate transfusion reactions in elders hospitalized in a public hospital in the Federal District. Methods: This is an observational, retrospective, documental, and analytical research, with a quantitative analysis of 516 transfusions of packed red blood cells in elders hospitalized in the largest public hospital, who required blood components, from June to December 2017, through descriptive statistics. Results: The sample corresponded to 46.36% of the total number of transfusions in elders in the period. The mean age was 70 years old. There were adverse effects (reactions to the transfusion) in 12 (2.3%) transfusions. Respiratory alterations (33.3%) and fever (23.8%) were the most common events. Conclusion: The incidence of reactions to the transfusion is below national and international rates, indicating probable undernotification, which could be associated to a lack of knowledge regarding its clinical manifestations and the lack of systematic monitoring of the transfusion.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Adverse Transfusion Reactions Notified to the Hemovigilance Information System "Sihevi-Ins" in Colombia
    Forero, Maria I. Bermudez
    Garcia, Michel
    Gardeazabal, Paula A.
    Soto, Jonathan A.
    TRANSFUSION, 2018, 58 : 112A - 112A
  • [32] A REPORTING SYSTEM FOR BLOOD COMPONENTS IN TRANSFUSION REACTIONS IN A UNIVERSITY HOSPITAL: THE NATIONAL HEMOVIGILANCE SYSTEM
    Shimodaira, S.
    Ishikawa, S.
    Kojima, S.
    Nakasone, N.
    Nakazawa, K.
    Hasegawa, Y.
    Honda, T.
    VOX SANGUINIS, 2009, 97 : 164 - 164
  • [33] Hemovigilance system in the university hospital three years analysis of transfusion incidents
    Rehacek, V
    VOX SANGUINIS, 2008, 95 : 150 - 150
  • [34] Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module
    Haass, Kathryn A.
    Sapiano, Mathew R. P.
    Savinkina, Alexandra
    Kuehnert, Matthew J.
    Basavaraju, Sridhar V.
    TRANSFUSION MEDICINE REVIEWS, 2019, 33 (02) : 84 - 91
  • [35] IMMEDIATE, NON-HAEMOLYTIC REACTIONS TO BLOOD TRANSFUSION - ANALYSIS OF A SERIES OF TRANSFUSIONS
    RAMGREN, O
    SKOLD, E
    TENGBERG, JE
    ACTA MEDICA SCANDINAVICA, 1958, 162 (03): : 211 - 223
  • [36] Incidence of adverse transfusion reactions in the Quebec's hemovigilance system 2000-2001
    Robillard, P
    Itaj, NK
    Garneau, N
    TRANSFUSION, 2003, 43 (09) : 22A - 22A
  • [37] Hypersensitivity transfusion reactions due to IgA deficiency are rare according to French hemovigilance data
    Tacquard, Charles
    Boudjedir, Karim
    Carlier, Monique
    Muller, Jean-Yves
    Gomis, Philippe
    Mertes, Paul Michel
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2017, 140 (03) : 884 - 885
  • [38] Transfusion-Related Adverse Reactions Reported to the National Healthcare Safety Network Hemovigilance Module - United States, 2010-2018
    Kracalik, Ian
    Mowla, Sanjida
    Basavaraju, Sridhar
    Sapiano, Matt
    TRANSFUSION, 2020, 60 : 14A - 15A
  • [39] Patterns of Adverse Transfusion Reactions in a Tertiary Care Centre of North India: A Step Towards Hemovigilance
    Bassi, Rajni
    Aggarwal, Shikha
    Bhardwaj, Kanchan
    Thakur, Kusum K.
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2017, 33 (02) : 248 - 253
  • [40] Patterns of Adverse Transfusion Reactions in a Tertiary Care Centre of North India: A Step Towards Hemovigilance
    Rajni Bassi
    Shikha Aggarwal
    Kanchan Bhardwaj
    Kusum K. Thakur
    Indian Journal of Hematology and Blood Transfusion, 2017, 33 : 248 - 253