Cardiac output measurement

被引:1
|
作者
Kolb, Benjamin [1 ]
Kapoor, Vikas [2 ]
机构
[1] North Manchester Gen Hosp, Anaesthesia, Manchester, Lancs, England
[2] North Manchester Gen Hosp, Manchester, Lancs, England
来源
关键词
Aortic Doppler; bioimpedance; cardiac output; indicator dilution; oesophageal Doppler; pulse contour analysis; pulse power analysis; pulse waveform analysis; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.1016/j.mpaic.2019.01.007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cardiac output measurement has become increasingly important in anaesthesia and critical care, particularly with the growing emphasis on perioperative medicine. Flow cannot be measured by any direct means and therefore models are employed to deduce useful information from other parameters. Numerous techniques are available, each with advantages and disadvantages in terms of invasiveness and validity. Often a balance is struck between invasiveness and validity of the measurements, with acceptance of trends monitoring in some cases, rather than absolute values of cardiac output.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 50 条
  • [31] CARDIAC-OUTPUT MEASUREMENT BY THERMODILUTION
    PELLETIER, C
    CANADIAN JOURNAL OF SURGERY, 1979, 22 (04) : 347 - 350
  • [32] THE MEASUREMENT OF CARDIAC OUTPUT - A NEW METHOD
    PETERSON, LH
    HELRICH, M
    GREENE, L
    TAYLOR, C
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1954, 228 (01): : 112 - 112
  • [33] MEASUREMENT OF CARDIAC OUTPUT BY THERMAL DILUTION
    SANMARCO, ME
    PHILIPS, CM
    MARQUEZ, LA
    HALL, C
    DAVILA, JC
    AMERICAN JOURNAL OF CARDIOLOGY, 1971, 28 (01): : 54 - &
  • [34] Cardiac output measurement by thermodilution in mice
    不详
    FASEB JOURNAL, 1996, 10 (03): : T14 - T14
  • [35] Comparison of methods for cardiac output measurement
    Kööbi, T
    Kaukinen, S
    Kauppinen, P
    CRITICAL CARE MEDICINE, 2001, 29 (05) : 1092 - 1092
  • [36] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    BULLER, NP
    LANCET, 1987, 1 (8526): : 215 - 215
  • [37] Cardiac output measurement in pediatric anesthesia
    Skowno, Justin J.
    Broadhead, Michael
    PEDIATRIC ANESTHESIA, 2008, 18 (11) : 1019 - 1028
  • [38] Measurement of Cardiac Output in Children by Bioreactance
    Yolanda Ballestero
    Jesús López-Herce
    Javier Urbano
    Maria José Solana
    Marta Botrán
    Jose M. Bellón
    Angel Carrillo
    Pediatric Cardiology, 2011, 32 : 469 - 472
  • [39] BIOIMPEDANCE MEASUREMENT OF CARDIAC-OUTPUT
    SMITH, DN
    CRITICAL CARE MEDICINE, 1994, 22 (09) : 1513 - 1514
  • [40] NONINVASIVE CARDIAC-OUTPUT MEASUREMENT
    WONG, DH
    WESTERN JOURNAL OF MEDICINE, 1990, 153 (03): : 310 - 310