COMPARISON OF DIFFERENT METHODS FOR VISCOUS DAMPER PLACEMENT IN EXISTING FRAME BUILDINGS

被引:0
|
作者
Landi, Luca [1 ]
Conti, Filippo [1 ]
Diotallevi, Pier Paolo [1 ]
机构
[1] Univ Bologna, Dept DICAM, Bologna, Italy
关键词
Damper distribution; Nonlinear viscous damper; Seismic retrofit; Design procedure; Nonlinear dynamic analyses;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The main purpose of this research is to investigate the effects of different vertical distributions of the properties of nonlinear fluid-viscous dampers for the retrofit of existing multi-story reinforced concrete frames. In particular, the different distributions are defined on the basis of the same value of the supplemental damping ratio. Since the viscous dampers are used for the retrofit of existing buildings, they are dimensioned assuming that the structure can exceed the elastic limit, with the only condition to satisfy the prefixed performance limit. In the design phase the different vertical distributions of damper properties are compared in terms of the total sum of the damping coefficients. The effectiveness of the different distributions is then examined by performing time-history analysis of several case studies considering a nonlinear behavior both for the viscous dampers and for the structural members. The results of the nonlinear dynamic analyses are examined in terms of inter-story drifts and dampers forces. The considered case studies are five RC frames characterized by different number of stories (3, 6 and 9 stories) and also by different properties in terms of regularity in elevation. In this way it is also possible to investigate the effect of the vertical distribution of the damper properties for regular and irregular frames.
引用
收藏
页码:275 / 280
页数:6
相关论文
共 50 条
  • [31] A comparison study of different dust control methods in pig buildings
    Takai, H
    Pedersen, S
    APPLIED ENGINEERING IN AGRICULTURE, 2000, 16 (03) : 269 - 277
  • [32] Odour from livestock buildings - A comparison of different evaluation methods
    Sowa, A
    Schirz, S
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2001, 61 (04): : 127 - 132
  • [33] Odour from livestock buildings - A comparison of different evaluation methods
    Sowa, A.
    Schirz, S.
    Gefahrstoffe Reinhaltung der Luft, 2001, 61 (04): : 127 - 132
  • [34] Effects of isolator properties on viscous damper capacity of base isolated adjacent buildings
    Kandemir-Mazanoglu, Elif Cagda
    JOURNAL OF VIBROENGINEERING, 2017, 19 (04) : 2739 - 2748
  • [35] Simplified methods for seismic assessment of existing buildings
    Tehranizadeh, Mohsen
    Amirmojahedi, Maryam
    Moshref, Amir
    EARTHQUAKES AND STRUCTURES, 2016, 10 (06) : 1405 - 1428
  • [36] OPTIMAL VISCOUS DAMPER PLACEMENT USING LEVEL SET TOPOLOGY OPTIMIZATION METHOD
    Ansari, Masoud
    Khajepour, Amir
    Esmailzadeh, Ebrahim
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 3, PTS A AND B, 2012, : 1119 - 1125
  • [37] A Comparison of Thermal Insulation with Interstitial Condensation in Different Climate Contexts in Existing Buildings in Europe
    Tronchin, Lamberto
    Fabbri, Kristian
    Tommasino, Maria Cristina
    ENERGIES, 2023, 16 (04)
  • [38] A practical design method to retrofit existing RC buildings with viscous dampers
    Gobirahavan, R.
    Wijeyewickrema, A. C.
    COMPUTATIONAL MODELLING OF CONCRETE STRUCTURES. EURO-C 2018, 2018, : 983 - 992
  • [39] A new method to assess the seismic vulnerability of existing wood frame buildings
    Loss, Cristiano
    Piazza, Maurizio
    Zonta, Daniele
    STRUCTURAL HEALTH ASSESSMENT OF TIMBER STRUCTURES, 2013, 778 : 486 - 494
  • [40] Seismic Fragility Evaluation of Existing RC Frame and URM Buildings in Algeria
    Mustapha Remki
    Abderrahmane Kibboua
    Djillali Benouar
    Fouad Kehila
    International Journal of Civil Engineering, 2018, 16 : 845 - 856