Effect of Ulnar Head Offset on Distal Radioulnar Joint Stability

被引:4
|
作者
Orbay, Jorge [1 ]
Vernon, Lauren [1 ]
Poirier, Sophia [1 ]
Morales, Victor [1 ]
Cambo, Richard [1 ]
Mercer, Deana [2 ]
机构
[1] Miami Hand & Upper Extrem Inst, 8905 SW 87th Ave, Miami, FL 33176 USA
[2] Univ New Mexico, Dept Orthoped & Rehabil, Albuquerque, NM 87131 USA
来源
关键词
Biomechanical; distal oblique interosseous ligament; distal radioulnar joint; instability; ulnar head replacement; FAILED RESECTION ARTHROPLASTIES; INTEROSSEOUS MEMBRANE; ANATOMY; BIOMECHANICS; FOREARM; IMPLANTS; LIGAMENT; SALVAGE; WRIST;
D O I
10.1016/j.jhsa.2020.12.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose A complete ulnar head replacement may be indicated in cases of distal radial ulnar joint (DRUJ) dysfunction to address bony pathology in lieu of using a constrained total DRUJ prosthesis. Complete ulnar head implants are simple, but they may be unstable if soft tissue tension is not adequately restored. We hypothesized that incorporating an increased offset in the complete ulnar head replacement would lead to increased tension on the distal oblique interosseous ligament, increased contact force at the DRUJ, and improved joint stability. Methods Using a specially designed jig, we measured instability by comparing displacement under load (stiffness) of the DRUJ in 10 cadaveric specimens under 4 different conditions: (1) intact, (2) native head after excision of the triangular fibrocartilage complex, (3) replacement of the ulnar head with a standard offset ulnar head, and (4) replacement of the ulnar head with an increased offset ulnar head. No soft tissue repair was done. We measured anteroposterior displacement under load with maximum translation of 10 mm or maximum loads of 50 N. We tested all specimens with the forearm positioned in neutral, supination, and pronation. Results Excising the triangular fibrocartilage complex decreased the average stiffness of the DRUJ to 46% of the intact state, creating a simulated state of DRUJ instability. Replacing the ulnar head with the standard offset head increased average stiffness to 54% of the intact state. Increasing the ulnar head offset with the simulated total ulnar head replacement increased average stiffness to 77% of the intact state. Conclusions An increased offset ulnar head replacement improves DRUJ stability compared with a standard anatomic offset ulnar head replacement. Clinical relevance Understanding DRUJ morphology and offset is important in the treatment of DRUJ arthritis and instability. Copyright (C) 2021 by the American Society for Surgery of the Hand. Published by Elsevier Inc.
引用
收藏
页码:816.e1 / 816.e7
页数:7
相关论文
共 50 条
  • [11] Ulnar-shortening effect on distal radioulnar joint pressure: A biomechanical study
    Nishiwaki, Masao
    Nakamura, Toshiyasu
    Nagura, Takeo
    Toyama, Yoshiaki
    Ikegami, Hiroyasu
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02): : 198 - 205
  • [12] The dorsopalmar stability of the distal radioulnar joint
    Stuart, PR
    Berger, RA
    Linscheid, RL
    An, KN
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (04): : 689 - 699
  • [13] Dislocation of the distal radioulnar joint associated with an intraarticular fracture of the ulnar head: Report of two cases
    Tamura, Y
    Inoue, G
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (01) : 68 - 70
  • [14] Salvage of failed resection arthroplasties of the distal radioulnar joint using a new ulnar head prosthesis
    van Schoonhoven, J
    Fernandez, DL
    Bowers, WH
    Herbert, TJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03): : 438 - 446
  • [15] Ulnar Head Fracture with Volar Dislocation of the Distal Radioulnar Joint: A Case Series and Systematic Review
    Samy, David Ananth
    Julian, Harriet S.
    Pe, Eindere Zaw
    Brown, Daniel
    JOURNAL OF WRIST SURGERY, 2024, 13 (06) : 584 - 588
  • [16] Ulnar head prosthesis following trauma. A treatment option for distal radioulnar joint injury?
    Sauerbier, M.
    TRAUMA UND BERUFSKRANKHEIT, 2010, 12 (01) : 24 - 31
  • [17] Distal radius fracture with concomitant ulnar styloid fracture: does distal radioulnar joint stability depend on the location of the ulnar styloid fracture?
    Kim, Kyung Wook
    Lee, Che Ho
    Choi, Jae Heouk
    Ahn, Joong Mo
    Gong, Hyun Sik
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 839 - 845
  • [18] Distal radius fracture with concomitant ulnar styloid fracture: does distal radioulnar joint stability depend on the location of the ulnar styloid fracture?
    Kyung Wook Kim
    Che Ho Lee
    Jae Heouk Choi
    Joong Mo Ahn
    Hyun Sik Gong
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 839 - 845
  • [19] The role of the distal radioulnar ligaments, interosseous membrane, and joint capsule in distal radioulnar joint stability
    Ward, LD
    Ambrose, CG
    Masson, MV
    Levaro, F
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (02): : 341 - 351
  • [20] Relative contributions of the ulnar attachments of the triangular fibrocartilage complex to the dynamic stability of the distal radioulnar joint
    Haugstvedt, JR
    Berger, RA
    Nakamura, T
    Neale, P
    Berglund, L
    An, KN
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 445 - 451