Neutron therapy using medical linacs

被引:0
|
作者
Adnani, N [1 ]
Fallone, BG [1 ]
机构
[1] Cross Canc Inst, Edmonton, AB T6G 1Z2, Canada
关键词
neutrons; linacs; BNCT; BNCEPT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Measurements of the neutron flux generated at depth in water by an 18 MV photon beam of a Varian 2100C linac are presented, The thermal neutron flux at depth exhibits a maximum at around 5 cm of 2.37 x 10(6) n/cm(2)/s fur a 40 x 40 cm(2) field size, 100 cm SSD and a photon output of 400 MU/min. Because of the low thermal neutron flux, a large concentration of boron-10 at the tumor is required to achieve significant dose deposition by boron neutron capture reaction, To reduce the concentration required at the tumor it is necessary to increase the irradiation time without a significant increase in the photon dose. This is found to be possible by completely closing the collimator jaws which results in a 1000 times reduction in the photon dose. Also the thermal neutron flux can be further increased by reducing the SSD to the minimum possible (50 cm in our case). In such conditions, the linac can be considered to be operating in a neutron beam mode. la addition, a 25 MV photon beam will generated 10 times more neutrons than an 18 MV beam This report demonstrates that boron neutron capture therapy and boron neutron capture enhanced photon therapy can be successfully performed using the neutron beam generated by high energy medical linacs.
引用
收藏
页码:133 / 136
页数:4
相关论文
共 50 条
  • [41] COMPARISON OF PHOTO-NEUTRON FLUENCE FOR DIFFERENT ENERGIES, MANUFACTURERS AND MODELS OF LINACS.
    Romero Exposito, M. T.
    Sanchez-Doblado, F.
    Terron, J. A.
    Domingo, C.
    Amgarou, K.
    Garcia-Fuste, M. J.
    Gonzalez Soto, X. L.
    Lagares, J. I.
    Gomez, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S168 - S168
  • [42] Melanoma and nonmelanoma neutron capture therapy using gene therapy: overview
    Mishima, Y
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A10 - A25
  • [43] Normal Tissue Doses During Isotoxically Dose Escalated Lung Radiation Therapy Using MR-Linacs
    Bendall, L.
    Fenwick, J. D.
    Papiez, B. W.
    Hawkins, M. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S207 - S207
  • [44] Feasibility Study On Three-Dimensional GRID Therapy in Conventional Linacs
    Yan, Y.
    Meyer, J.
    Timmerman, R.
    Hrycushko, B.
    Chen, B.
    Saha, D.
    Jiang, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3432 - 3432
  • [45] PLASMA WAKEFIELD ACCELERATION EXPERIMENTS USING TWIN LINACS
    OGATA, A
    NAKANISHI, H
    KAWAKUBO, T
    ARINAGA, M
    NAKAJIMA, K
    WHITTUM, D
    YOSHIDA, Y
    UEDA, T
    KOBAYASHI, T
    SHIBATA, H
    YUGAMI, N
    NISHIDA, Y
    PHYSICA SCRIPTA, 1994, T52 : 69 - 72
  • [46] Dynamic Infrared Imaging for Biological and Medical Applications in Boron Neutron Capture Therapy
    Santa Cruz, Gustavo A.
    Gonzalez, Sara J.
    Dagrosa, Alejandra
    Schwint, Amanda E.
    Carpano, Marina
    Trivillin, Veronica A.
    Boggio, Esteban F.
    Bertotti, Jose
    Marin, Julio
    Monti Hughes, Andrea
    Molinari, Ana J.
    Albero, Miguel
    THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXIII, 2011, 8013
  • [47] Technical aspects of boron neutron capture therapy at the BNL Medical Research Reactor
    Holden, NE
    Rorer, DC
    Patti, FJ
    Liu, HB
    Reciniello, R
    Chanana, AD
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 1674 - 1676
  • [48] Application and Feasibility Design Research of Boron Neutron Capture Therapy on Medical Ship
    Guo Z.
    Fan Y.
    Zan H.
    Wan H.
    Ke G.
    Chen H.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (02): : 320 - 326
  • [49] PRELIMINARY CLINICAL RESULTS OF FAST-NEUTRON THERAPY WITH NIRS MEDICAL CYCLOTRON
    MORITA, S
    TSUNEMOTO, H
    UMEGAKI, Y
    URANO, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 3 : 281 - 282
  • [50] DOSIMETRY AT BROOKHAVEN MEDICAL RESEARCH REACTOR IN REGARD TO NEUTRON-CAPTURE THERAPY
    FAIRCHILD, RG
    ARCHAMBE.JO
    TONNA, EA
    SEIBOLD, CT
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1966, 9 (01): : 73 - +