Five-year experience with pulmonary vein isolation using the second-generation cryoballoon for treatment of persistent atrial fibrillation

被引:8
|
作者
Akkaya, Ersan [1 ,2 ]
Berkowitsch, Alexander [1 ]
Zaltsberg, Sergej [1 ]
Greiss, Harald [1 ]
Hamm, Christian W. [1 ,3 ]
Sperzel, Johannes [1 ]
Neumann, Thomas [1 ]
Kuniss, Malte [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, Benekestr 2-8, D-61231 Bad Nauheim, Germany
[2] Jung Stilling Heart Ctr, Dept Cardiol, Siegen, Germany
[3] Justus Liebig Univ, Med Clin 1, Giessen, Germany
关键词
learning curve; persistent atrial fibrillation; predictors; pulmonary vein isolation; second-generation cryoballoon; FOLLOW-UP; SINGLE PROCEDURE; ABLATION; RECOMMENDATIONS; CATHETER; OUTCOMES; FREEZE; TRIAL; 1ST;
D O I
10.1111/jce.13743
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction We analyzed the procedural experience and clinical outcome after pulmonary vein isolation (PVI) in patients with persistent atrial fibrillation (AF) gained over 5 years using the second-generation cryoballoon (CB-Adv). Methods and Results Conclusions For this retrospective study, we enrolled 281 patients undergoing PVI at our institution between 2012 and 2016. The analyzed period was divided into 5 calendar years. Follow-up data, including Holter electrocardiography recordings, were collected during outpatient clinic visits. The impact of several variables on outcome was evaluated by means of univariate and multivariate analyses and Cox proportional hazards regression models. The median procedure and fluoroscopy times over the years were 90 (72 of 114) and 15 (11 of 21) minutes, respectively. A continuous decline in complication rates and fluoroscopy and procedure times was observed in each subsequent year. During mid-term follow-up (33 [25 of 48] months), 178 (63.3%) patients were AF, atrial flutter, or atrial tachycardia free. Multivariate analysis revealed left atrial area (hazard ratio [HR] = 1.05; P < 0.001), female sex (HR = 2.53; P < 0.001), and common ostium (HR = 1.93; P < 0.001) as significant predictors of outcome. The overall 1-year success rate was 76.2%. A gradual decrease in the 1-year success rate (from 90.5% in 2012 to 67.9% in 2016) was mainly related to a steady increase of left atrial area in the entire cohort with successive years of the study. PVI using CB-Adv in patients with persistent AF is accompanied by a learning curve and facilitates a satisfactory outcome, followed by the proper selection of patients.
引用
收藏
页码:1500 / 1507
页数:8
相关论文
共 50 条
  • [41] Electrical isolation of the superior vena cava using second-generation cryoballoon in patients with atrial fibrillation
    Wei, Hui-Qiang
    Guo, Xiao-Gang
    Sun, Qi
    Yang, Jian-Du
    Xie, Hai-Yang
    Cao, Zhong-Jing
    Chen, Yan-Qiao
    Zhang, Shu
    Wu, Shulin
    Ma, Jian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1307 - 1314
  • [42] Patterns of posterior wall isolation using the second-generation cryoballoon for atrial fibrillation ablation: A single-center experience
    Casale, Joel A.
    Kittel, Tyler
    Vivas, Yoel
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1748 - 1748
  • [43] Hybrid Cryoballoon Pulmonary Vein Isolation and Radiofrequency Posterior Wall Isolation for Persistent Atrial Fibrillation
    Nguyen, Heajung L.
    Macias, Carlos
    Khakpour, Houman
    Bradfield, Jason S.
    Shivkumar, Kalyanam
    Buch, Eric F.
    CIRCULATION, 2020, 142
  • [44] Novel second-generation cryoballoon: improved procedural efficacy of pulmonary vein isolation
    Kuniss, M.
    Greiss, H.
    Zaltsberg, S.
    Pajitnev, D.
    Berkowitsch, A.
    Akkaya, E.
    Hamm, C.
    Neumann, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 431 - 432
  • [45] One-Year Clinical Outcome of Pulmonary Vein Isolation Using the Second-Generation Cryoballoon: A Meta-Analysis
    He, Xin
    Chen, Yili
    Zhou, Yue
    Huang, Yiyi
    He, Jiangui
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (02): : 182 - 189
  • [46] Optimal diameter of the pulmonary vein ostium for second-generation 28-mm cryoballoon ablation of atrial fibrillation
    Kurokawa, Sayaka
    Nagashima, Koichi
    Watanabe, Ryuta
    Arai, Masaru
    Wakamatsu, Yuji
    Otsuka, Naoto
    Yagyu, Seina
    Nakai, Toshiko
    Okumura, Yasuo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (02): : 201 - 209
  • [47] Clinical outcome of the 2nd generation cryoballoon for pulmonary vein isolation in patients with persistent atrial fibrillation
    Jansson, Victoria
    Mortsell, David
    Malmborg, Helena
    Lonnerholm, Stefan
    Lundqvist, Carina Blomstrom
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1739 - 1740
  • [48] Concomitant Pulmonary Vein and Posterior Wall Isolation Using Cryoballoon With Adjunct Radiofrequency in Persistent Atrial Fibrillation
    Aryana, Arash
    Allen, Shelley L.
    Pujara, Deep K.
    Bowers, Mark R.
    O'Neill, Padraig Gearoid
    Yamauchi, Yasuteru
    Shigeta, Takatoshi
    Vierra, Eleanor C.
    Okishige, Kaoru
    Natale, Andrea
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (02) : 187 - 196
  • [49] Analysis of procedural data of pulmonary vein isolation for atrial fibrillation with the second-generation laser balloon
    Nagase, Takahiko
    Bordignon, Stefano
    Perrotta, Laura
    Bologna, Fabrizio
    Tsianakas, Nikolaos
    Chen, Shaojie
    Konstantinou, Athanasios
    Chun, Julian K. R.
    Schmidt, Boris
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 837 - 845
  • [50] Atrioventricular conduction disturbance during pulmonary vein isolation using the second-generation cryoballoon - Vagal impact of cryoballoon ablation
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Hada, Masahiro
    Yamao, Kazuya
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Tada, Hiroshi
    Hirao, Kenzo
    Iesaka, Yoshito
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 265 : 113 - 117