The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair

被引:4
|
作者
Bernstein, Derek T. [1 ]
Alexander, Jamie J. [2 ]
Petersen, Nancy J. [3 ]
Lambert, Bradley S. [1 ]
Noble, Philip C. [2 ]
Netscher, David T. [2 ]
机构
[1] Houston Methodist Hosp, Dept Orthopaed Surg, Houston, TX USA
[2] Baylor Coll Med, Dept Orthopaed Surg, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Med, Sect Hlth Serv Res, Houston, TX 77030 USA
来源
关键词
Flexor tendon repair; zone II; looped; caliber; suture; suture-tendon interface; STRENGTH; LOCKING; PURCHASE; STRANDS;
D O I
10.1016/j.jhsa.2018.04.029
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To evaluate the impact of suture caliber and looped configurations on the integrity of 4-strand modified Kessler zone II flexor tendon repairs during progressive cyclic loading. Methods Seventy-two flexor digitorum profundus tendons from 18 fresh human cadaver hands were divided into 4 repair groups. Thirty-six matched tendons underwent repair using either a 4-0 looped or 4-0 single-stranded suture, and an additional 36 tendons underwent 3-0 looped or 3-0 single-stranded repairs. Repair strength was tested by progressive cyclic loading. The force generating 2-mm gap formation, ultimate failure, and the mechanism of failure were recorded for each test. The impact of looped versus single-stranded configurations and the effect of tendon cross-sectional area on repair integrity were analyzed for each suture caliber. Results There was no statistically significant difference between groups regarding the force to 2-mm gap formation or ultimate failure, and all values exceeded the minimum threshold of 27 N required to withstand an early active range of motion rehabilitation protocol. The use of a 3-0 caliber suture resulted in a significantly higher proportion of repairs failing by suture pullout through the tendon substance, including 63.5% of looped and 38.9% of single-stranded core sutures. By comparison, this occurred in 11.1% of 4-0 looped and 0% of 4-0 single-stranded sutures. Larger tendon cross-sectional areas were associated with more robust repairs, particularly in the 3-0 looped group. Conclusions In a human cadaver flexor tendon repair model, there was no significant difference in the mean force to failure between all 4 flexor tendon repair constructs under progressive cyclic loading. However, the 3-0 caliber suture failed more frequently by suture pullout, particularly with the use of a looped suture. Copyright (C) 2019 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:156.e1 / 156.e8
页数:8
相关论文
共 50 条
  • [21] COMPARATIVE MECHANICAL ANALYSIS OF A LOOPED-SUTURE TENDON REPAIR
    HADDAD, RJ
    KESTER, MA
    MCCLUSKEY, GM
    BRUNET, ME
    COOK, SD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (05): : 709 - 713
  • [22] Effect of the Number of Suture Throws on the Biomechanical Characteristics of the Suture-Tendon Construct
    Hong, Chih-Kai
    Lin, Cheng-Li
    Chang, Chih-Hsun
    Jou, I-Ming
    Su, Wei-Ren
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (12): : 1609 - 1615
  • [23] Clinical use of a combined grasping and locking core suture technique for flexor tendon repair in zone II
    Al-Qattan, Mohammad M.
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2013, 47 (06) : 438 - 441
  • [24] Enhanced Zone II Flexor Tendon Repair through a New Half Hitch Loop Suture Configuration
    Kormpakis, Ioannis
    Linderman, Stephen W.
    Thomopoulos, Stavros
    Gelberman, Richard H.
    PLOS ONE, 2016, 11 (04):
  • [25] Flexor Tendon Zone II Repair
    Hong, Daniel Y.
    Strauch, Robert J.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (04):
  • [26] Biomechanical evaluation of suture-tendon interface and tissue holding of three suture configurations in torn and degenerated versus intact human rotator cuffs
    Wlk, Matthias V.
    Abdelkafy, Ashraf
    Hexel, Michael
    Krasny, Christian
    Aigner, Nicolas
    Meizer, Roland
    Landsiedl, Franz
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (02) : 386 - 392
  • [27] The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    Wieskoetter, B.
    Herbort, M.
    Langer, M.
    Raschke, M. J.
    Waehnert, D.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (01) : 139 - 145
  • [28] The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    B. Wieskötter
    M. Herbort
    M. Langer
    M. J. Raschke
    D. Wähnert
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 139 - 145
  • [29] Comparison of pullout button versus suture anchor for zone I flexor tendon repair
    McCallister, WV
    Ambrose, HC
    Katolik, LI
    Trumble, TE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (02): : 246 - 251
  • [30] Flexor tendon suture methods: A quantitative analysis of suture material within the repair site
    Norris, SR
    Ellis, FD
    Chen, MI
    Seller, JC
    ORTHOPEDICS, 1999, 22 (04) : 413 - 416