Noise susceptibility of cochlear implant users: The role of spectral resolution and smearing

被引:151
|
作者
Fu, QJ [1 ]
Nogaki, G [1 ]
机构
[1] House Ear Res Inst, Dept Auditory Implants & Percept, Los Angeles, CA 90057 USA
关键词
noise susceptibility; cochlear implants; spectral resolution; spectral smearing; gated noise;
D O I
10.1007/s10162-004-5024-3
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of background noise increases. Previous studies have shown that, for cochlear implant users, the absence of fine spectro-temporal cries may contribute to poorer performance in noise, especially Mien the noise is dynamic (e.g., competing speaker or modulated noise). Here we report on sentence recognition by cochlear implant users and by normal-hearing subjects listening to an acoustic simulation of a cochlear implant, in the presence of stead), or square-wave modulated speech-shaped noise. Implant users were tested using their everyday, clinically assigned speech processors. In the acoustic simulation, normal-hearing listeners were tested for different degrees of spectral resolution (16, eight, or four channels) and spectral smearing (carrier filter slopes of -24 or -6 dB/octave). For Modulated noise, normal-hearing listeners experienced significant release from masking when the original, unprocessed speech was presented (which preserved the spectro-temporal fine structure), while cochlear implant users experienced no release from masking. As the spectral resolution was reduced, normal-hearing listeners release from masking gradually diminished. Release from masking was further reduced as the degree of spectral smearing increased. Interestingly, the mean speech recognition thresholds of implant users were very close to those of normal-hearing subjects listening to four-channel spectrally smeared noise-band speech. Also, the best cochlear implant listeners performed like normal-hearing subjects listening to eight- to 16-channel spectrally smeared noise-band speech. These findings Suggest that implant users' susceptibility to noise may be caused by the reduced spectral resolution and the high degree of spectral smearing associated with channel interaction. Efforts to improve the effective number of spectral channels as well as reduce channel interactions May improve implant performance in noise, especially for temporally modulated noise.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [11] ALGORITHMS TO IMPROVE LISTENING IN NOISE FOR COCHLEAR IMPLANT USERS
    Hersbach, Adam A.
    Mauger, Stefan J.
    Grayden, David B.
    Fallon, James B.
    McDermott, Hugh J.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 428 - 432
  • [12] Abnormal Binaural Spectral Integration in Cochlear Implant Users
    Lina A. J. Reiss
    Rindy A. Ito
    Jessica L. Eggleston
    David R. Wozny
    Journal of the Association for Research in Otolaryngology, 2014, 15 : 235 - 248
  • [13] The acceptance of background noise in adult cochlear implant users
    Plyler, Patrick N.
    Bahng, Junghwa
    von Hapsburg, Deborah
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2008, 51 (02): : 502 - 515
  • [14] Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users
    Anderson, Elizabeth S.
    Nelson, David A.
    Kreft, Heather
    Nelson, Peggy B.
    Oxenham, Andrew J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (01): : 364 - 375
  • [15] Assessing the role of spectral and intensity cues in spectral ripple detection and discrimination in cochlear-implant users
    Anderson, Elizabeth S.
    Oxenham, Andrew J.
    Nelson, Peggy B.
    Nelson, David A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 132 (06): : 3925 - 3934
  • [16] Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners
    Chen, Biao
    Shi, Ying
    Kong, Ying
    Chen, Jingyuan
    Zhang, Lifang
    Li, Yongxin
    Galvin, John J.
    Fu, Qian-Jie
    TRENDS IN HEARING, 2023, 27
  • [17] Perception of Iterated Rippled Noise Periodicity in Cochlear Implant Users
    Wagner, Luise
    Plontke, Stefan K.
    Rahne, Torsten
    AUDIOLOGY AND NEURO-OTOLOGY, 2017, 22 (02) : 104 - 115
  • [18] Benefit of the UltraZoom beamforming technology in noise in cochlear implant users
    Isabelle Mosnier
    Nathalie Mathias
    Jonathan Flament
    Dorith Amar
    Amelie Liagre-Callies
    Stephanie Borel
    Emmanuèle Ambert-Dahan
    Olivier Sterkers
    Daniele Bernardeschi
    European Archives of Oto-Rhino-Laryngology, 2017, 274 : 3335 - 3342
  • [19] Spectral loudness summation for electrical stimulation in cochlear implant users
    Theelen-van den Hoek, Femke L.
    Boymans, Monique
    Dreschler, Wouter A.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (11) : 818 - 827
  • [20] Benefit of the UltraZoom beamforming technology in noise in cochlear implant users
    Mosnier, Isabelle
    Mathias, Nathalie
    Flament, Jonathan
    Amar, Dorith
    Liagre-Callies, Amelie
    Borel, Stephanie
    Ambert-Dahan, Emmanuele
    Sterkers, Olivier
    Bernardeschi, Daniele
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (09) : 3335 - 3342