Correction methods for random coincidences in fully 3D whole-body PET: Impact on data and image quality

被引:0
|
作者
Brasse, D
Kinahan, PE
Lartizien, C
Comtat, C
Casey, M
Michel, C
机构
[1] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
[2] ULP, CNRS, Inst Rech Subatom, Strasbourg, France
[3] Univ Lyon 1, CERMEP, Hop Neurol, F-69365 Lyon, France
[4] CEA, Dept Med Res, SHFJ, Orsay, France
[5] CPS Innovat, Knoxville, TN USA
关键词
fully 3-dimensional whole-body PET; random coincidences; image quality; NEC; SNR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the advantages of the increased sensitivity of fully 3-dimensional (30) PET for whole-body imaging come the challenges of more complicated quantitative corrections and, in particular. an increase in the number of random coincidences. The most common method of correcting for random coincidences is the real-time subtraction of a delayed coincidence channel, which does not add bias but increases noise. An alternative approach is the postacquisition subtraction of a low-noise random coincidence estimate, which can be obtained either from a smoothed delayed coincidence sinogram or from a calibration scan or directly estimated. Each method makes different trade-offs between noise amplification, bias, and data-processing requirements. These trade-offs are dependent on activity injected, the local imaging environment (e.g., near the bladder), and the reconstruction algorithm. Methods: Using fully 3D whole-body simulations and phantom studies, we investigate how the gains in noise equivalent count (NEC) rates from using a noiseless random coincidence estimation method are translated to improvements n image signal-to-noise ratio (SNR). The image SNR, however, depends on the image reconstruction method and the local imaging environment. Results: We show that for fully 3D whole-body imaging using a particular set of scanners and clinical protocols, a low-noise estimate of random coincidences improves sinogram and image SNRs by approximate y 15% compared with online subtraction of delayed coincidences. Conclusion: A 15% improvement in image SNR arises from a 32% increase in the NEC rate. Thus, scan duration can be reduced by 25% while still maintaining a constant total acquired NEC.
引用
收藏
页码:859 / 867
页数:9
相关论文
共 50 条
  • [21] Impact of body habitus on quatitative and qualitative image quality in whole-body FDG-PET
    Tatsumi, M
    Clark, PA
    Nakamoto, Y
    Wahl, RL
    RADIOLOGY, 2002, 225 : 199 - 199
  • [22] A prototype axial shield for use in 3D whole-body PET
    Cutler, PD
    Laforest, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 10 - 15
  • [23] Whole-body PET scanner produces 3D images in seconds
    Sara Reardon
    Nature, 2019, 570 : 285 - 286
  • [24] Evaluating image quality for whole-body PET oncology imaging
    Kinahan, PE
    Lartizien, C
    Kim, JS
    Comtat, C
    Lewellen, TK
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 254P - 254P
  • [25] Whole-body 3D scanner and scan data report
    Addleman, S
    THREE-DIMENSIONAL IMAGE CAPTURE, 1997, 3023 : 2 - 5
  • [26] Evaluation of the count recovery coefficient of a whole-body PET/CT scanner in 3D mode image
    Tsujikawa, T.
    Okazawa, H.
    Ohtsuka, H.
    Morita, N.
    Nishitani, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S313 - S313
  • [27] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    高飞
    Yamada Ryoko
    Watanabe Mitsuo
    刘华锋
    Chinese Physics B, 2009, 18 (07) : 3066 - 3072
  • [28] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    Gao Fei
    Ryoko, Yamada
    Mitsuo, Watanabe
    Liu Hua-Feng
    CHINESE PHYSICS B, 2009, 18 (07) : 3066 - 3072
  • [29] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1362 - 1366
  • [30] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, Thomas
    Kinahan, Paul E.
    Townsend, David W.
    IEEE Transactions on Nuclear Science, 1997, 44 (6 pt 2): : 2400 - 2407