Correction methods for random coincidences in fully 3D whole-body PET: Impact on data and image quality

被引:0
|
作者
Brasse, D
Kinahan, PE
Lartizien, C
Comtat, C
Casey, M
Michel, C
机构
[1] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
[2] ULP, CNRS, Inst Rech Subatom, Strasbourg, France
[3] Univ Lyon 1, CERMEP, Hop Neurol, F-69365 Lyon, France
[4] CEA, Dept Med Res, SHFJ, Orsay, France
[5] CPS Innovat, Knoxville, TN USA
关键词
fully 3-dimensional whole-body PET; random coincidences; image quality; NEC; SNR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the advantages of the increased sensitivity of fully 3-dimensional (30) PET for whole-body imaging come the challenges of more complicated quantitative corrections and, in particular. an increase in the number of random coincidences. The most common method of correcting for random coincidences is the real-time subtraction of a delayed coincidence channel, which does not add bias but increases noise. An alternative approach is the postacquisition subtraction of a low-noise random coincidence estimate, which can be obtained either from a smoothed delayed coincidence sinogram or from a calibration scan or directly estimated. Each method makes different trade-offs between noise amplification, bias, and data-processing requirements. These trade-offs are dependent on activity injected, the local imaging environment (e.g., near the bladder), and the reconstruction algorithm. Methods: Using fully 3D whole-body simulations and phantom studies, we investigate how the gains in noise equivalent count (NEC) rates from using a noiseless random coincidence estimation method are translated to improvements n image signal-to-noise ratio (SNR). The image SNR, however, depends on the image reconstruction method and the local imaging environment. Results: We show that for fully 3D whole-body imaging using a particular set of scanners and clinical protocols, a low-noise estimate of random coincidences improves sinogram and image SNRs by approximate y 15% compared with online subtraction of delayed coincidences. Conclusion: A 15% improvement in image SNR arises from a 32% increase in the NEC rate. Thus, scan duration can be reduced by 25% while still maintaining a constant total acquired NEC.
引用
收藏
页码:859 / 867
页数:9
相关论文
共 50 条
  • [1] Correction methods for random coincidences in 3D wholebody PET imaging
    Brasse, D
    Kinahan, PE
    Lartizien, C
    Comtat, C
    Casey, M
    Michel, C
    Bruckbauer, T
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2080 - 2084
  • [2] Source of impaired image quality in 3D whole-body FDG PET scanning
    Anne M. J. Paans
    Sabine M. M. Boerdijk
    Antoon T. M. Willemsen
    Jan Pruim
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 1207 - 1207
  • [3] Source of impaired image quality in 3D whole-body FDG PET scanning
    Paans, AMJ
    Boerdijk, SMM
    Willemsen, ATM
    Pruim, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) : 1207 - 1207
  • [4] Impact of elastic motion correction on quantitation and image quality of whole-body PET/CT
    Meier, Joseph
    Hamill, James
    Jones, Judson
    Hong, Inki
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [5] Strategies to improve 3D whole-body PET image reconstruction
    Cutler, PD
    Xu, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1453 - 1467
  • [6] Source of impaired image quality in 3D whole-body FDG PET scanning - Reply
    Everaert, H
    Vanhove, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (08) : 1208 - 1208
  • [7] METHODS FOR IMPROVING IMAGE QUALITY IN WHOLE-BODY PET SCANNING
    DAHLBOM, M
    YU, DC
    CHERRY, SR
    CHATZIIOANNOU, A
    HOFFMAN, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 1079 - 1083
  • [8] Simulation of Random Coincidences in Whole Body 3D Total PET with GATEv8.0
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    Dadouch, Ahmed
    Mribah, Amina
    El Hajami, Abdelhamid
    Didi, Abdessamad
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2019, 74 (06) : 669 - 674
  • [9] Simulation of Random Coincidences in Whole Body 3D Total PET with GATEv8.0
    Adil Bardane
    Jaouad Tajmouaati
    Abdelmajid Maghnouj
    Ahmed Dadouch
    Amina Mribah
    Abdelhamid El Hajami
    Abdessamad Didi
    Moscow University Physics Bulletin, 2019, 74 : 669 - 674
  • [10] Parameterization of a model-based 3D whole-body PET scatter correction
    Wollenweber, SD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1471 - 1475