Space-resolved determination of the mineral nutrient content in tree-rings by X-ray fluorescence

被引:11
|
作者
Ortega Rodriguez, Daigard Ricardo [1 ]
de Almeida, Eduardo [2 ]
Tomazello-Filho, Mario [1 ]
Pereira de Carvalho, Hudson Wallace [2 ]
机构
[1] Urt Sao Paulo, Luiz de Queiroz Coll Agr, Dept Forest Resource, Av Padua Dias 11, BR-13418900 Piracicaba, SP, Brazil
[2] Univ Sao Paulo, Ctr Nucl Energy Agr, Av Centenario 303, BR-13416000 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dendrochemistry; X-ray fluorescence; Forest nutrition; Fertilizer management; Trace elements; Non-destructive method; INDUCED BREAKDOWN SPECTROSCOPY; PLANT MATERIALS; ENVIRONMENTAL FORENSICS; ELEMENTAL COMPOSITION; NORWAY SPRUCE; WOOD; XRF; POTASSIUM; DENDROCHEMISTRY; QUANTIFICATION;
D O I
10.1016/j.scitotenv.2019.134537
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
X-ray fluorescence spectroscopy (XRF) offers rapid, multi-elemental, low cost and non-destructive elemental analysis. Different studies have used this technique to investigate distribution and concentration of essential and deleterious elements in vegetation. Special emphasis has been recently placed on the key aspects concerning sampling processes, laboratory protocols and calibration methods for quantitative analysis. The aim of the present study was to develop a quantitative methodology to determine the nutrient content in Pinus taeda tree-rings by XRF. Using a 1 mm X-ray excitation beam from a Rh X-ray tube at 30 kV and 600 mu A, and dwell time of 20 s, we present calibration curves for P, S, K, Ca, Mn and Fe based on multi-elemental standard addition using wood matrix of 17-year-old Pinus taeda trees. Satisfactory recoveries of our XRF approach for Ca, P, Mn, S and K (<115%), and tolerable for Fe (123%) were obtained compared to inductively coupled plasma optical emission spectrometry results. The non-destructive and quantitative XRF method allows assessing annual element concentrations of P. taeda trees, in order to provide tools for monitoring the nutrient dynamic in an experimental plantation. Furthermore, a method for elemental quantification based on multi-elemental standard addition using wood matrix is described as a useful procedure for future applications. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter
    So Hatakeyama
    Shinsuke Kunimura
    Nobuharu Sasaki
    Takashi Yamamoto
    Jun Kawai
    Analytical Sciences, 2008, 24 : 847 - 850
  • [42] Spatially resolved X-ray fluorescence analysis with a pyroelectric X-ray emitter
    Hatakeyama, So
    Kunimura, Shinsuke
    Sasaki, Nobuharu
    Yamamoto, Takashi
    Kawai, Jun
    ANALYTICAL SCIENCES, 2008, 24 (07) : 847 - 850
  • [43] Determination of the total sulphur content in black liquor by x-ray fluorescence
    Louhelainen, J
    Alén, R
    Isoaho, JR
    JOURNAL OF PULP AND PAPER SCIENCE, 2005, 31 (01): : 57 - 61
  • [44] Two dimensionally space-resolved electron temperature measurement of fusion plasma by x-ray monochromatic imaging method
    Fujita, K
    Nishimura, H
    Uschmann, I
    Forster, E
    Takabe, H
    Kato, Y
    Nakai, S
    LASER INTERACTION AND RELATED PLASMA PHENOMENA, 1996, (369): : 544 - 549
  • [45] X-Ray Fluorescence Determination of the Boron Content in Lithium Borate Glasses
    Finkelshtein, A. L.
    Dergin, A. A.
    Nepomnyashchikh, A., I
    Amosova, A. A.
    Chubarov, V. M.
    GLASS PHYSICS AND CHEMISTRY, 2022, 48 (01) : 6 - 9
  • [46] X-Ray Fluorescence Determination of the Boron Content in Lithium Borate Glasses
    A. L. Finkelshtein
    A. A. Dergin
    A. I. Nepomnyashchikh
    A. A. Amosova
    V. M. Chubarov
    Glass Physics and Chemistry, 2022, 48 : 6 - 9
  • [47] Imaging the space-resolved chemical heterogeneity of degraded graphite anode through scanning transmission X-ray microscope
    Zhu, Qingjun
    Sun, Gang
    Wang, Panpan
    Sui, Xulei
    Liu, Chang
    Wang, Jian
    Zhou, Jigang
    Wang, Zhenbo
    JOURNAL OF POWER SOURCES, 2024, 591
  • [48] Demonstration of space-resolved x-ray Thomson scattering capability for warm dense matter experiments on the Z accelerator
    Ao, T.
    Harding, E. C.
    Bailey, J. E.
    Lemke, R. W.
    Desjarlais, M. P.
    Hansen, S. B.
    Smith, I. C.
    Geissel, M.
    Maurer, A.
    Reneker, J.
    Romero, D.
    Sinars, D. B.
    Rochau, G. A.
    Benage, J. F.
    HIGH ENERGY DENSITY PHYSICS, 2016, 18 : 26 - 37
  • [49] Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source
    Sheftman, D.
    Shafer, D.
    Efimov, S.
    Gruzinsky, K.
    Gleizer, S.
    Krasik, Ya. E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [50] Secondary ion mass spectroscopy and synchrotron X-ray fluorescence in the study of the qualitative variation in metal content with time in tree rings
    Martin, RR
    Sham, TK
    Won, GW
    van der Heide, P
    Jones, KW
    Song, SR
    Protz, R
    CANADIAN JOURNAL OF FOREST RESEARCH, 1998, 28 (10) : 1464 - 1470