High-precision analysis of calcium isotopes using a Nu Sapphire collision cell (CC)-MC-ICP-MS

被引:13
|
作者
Gao, Bing-Yu [1 ]
Su, Ben-Xun [1 ,2 ]
Li, Wen-Jun [1 ]
Yuan, Meng [1 ,2 ]
Sun, Jian [3 ]
Zhao, Ye [4 ]
Liu, Xia [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Geol & Geophys, Key Lab Mineral Resources, Beijing 100029, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Geol Sci, Inst Geol, MNR Key Lab Isotope Geol, Key Lab Deep Earth Dynam,Minist Nat Resources, Beijing 100037, Peoples R China
[4] Nu Instruments, Unit 74 Clywedog Rd South,Wrexham Ind Estate, Wrexham LL13 9XS, Wales
关键词
MC-ICP-MS; CA ISOTOPES; IGNEOUS ROCKS; FRACTIONATION; MANTLE; DELTA-CA-44/40; CONSTRAINTS; SYSTEMATICS; CARBONATES; INSIGHTS;
D O I
10.1039/d2ja00150k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents high-precision analyses of calcium (Ca) isotope ratios using a collision-cell multi-collector inductively coupled plasma mass spectrometer (CC-MC-ICP-MS, Nu Sapphire). This instrument allows Ca isotope measurement in the low resolution mode, requiring much less sample compared with TIMS and conventional MC-ICP-MS, and has additional measurement capability of both radiogenic (epsilon Ca-40) and stable isotope ratios (delta Ca-44/40 and delta Ca-44/42). The effects of several factors on the precision and accuracy of Ca isotopic data were evaluated, including the total Ca concentration, Ca intensity mismatch between the sample and standard, HNO3 molarity mismatch between the sample and standard, and the presence of matrix elements. High precision was obtained on 100 ng g(-1) Ca samples (i.e., for 6 replicates similar to 600 ng of Ca). Accurate measurements require the following conditions: (1) Ca intensities matched within 3% between the sample and standard, (2) low contents of Sr, Mg and Cr (Sr/Ca, Mg/Ca and Cr/Ca ratios need to be lower than 0.01%, and K/Ca, Al/Ca, Ti/Ca and Cr/Ca ratios <1%). Eleven standard reference materials analyzed using the established method yield highly consistent Ca isotope results with literature values. The long-term external precisions are higher than 0.07 parts per thousand (2 SD) for delta Ca-44/40 and higher than 0.05 parts per thousand (2 SD) for delta Ca-44/42. The slope of the fractionation line between delta Ca-44/40 and delta Ca-44/42 is 1.9616 +/- 0.0794, within the error of the slope value from the exponential law.
引用
收藏
页码:2111 / 2121
页数:11
相关论文
共 50 条
  • [31] Potassium isotopic composition of seven widely available biological standards using collision cell (CC)-MC-ICP-MS
    Moynier, Frederic
    Hu, Yan
    Dai, Wei
    Kubik, Edith
    Mahan, Brandon
    Moureau, Julien
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (11) : 2444 - 2448
  • [32] High precision cadmium isotopic measurements by MC-ICP-MS
    Cloquet, C
    Carignan, J
    Libourel, G
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A144 - A144
  • [33] High precision Rb isotope measurements by MC-ICP-MS
    Hu, Xia
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2744 - 2755
  • [35] High accuracy measurements of Fe isotopes using hexapole collision cell MC-ICP-MS and isotope dilution for certification of reference materials
    Vogl, J
    Klingbeil, P
    Pritzkow, W
    Riebe, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) : 1125 - 1132
  • [36] High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket
    Li, Ming
    Lei, Yv
    Feng, Lanping
    Wang, Zaicong
    Belshaw, Nick S.
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chen, Haihong
    Chai, Xinna
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1707 - 1719
  • [37] High-precision Mg isotope analyses of low-Mg rocks by MC-ICP-MS
    An, Yajun
    Wu, Fei
    Xiang, Yuanxin
    Nan, Xiaoyun
    Yu, Xun
    Yang, Jinhui
    Yu, Huimin
    Xie, Liewen
    Huang, Fang
    CHEMICAL GEOLOGY, 2014, 390 : 9 - 21
  • [38] Sequential separation of cerium (Ce) and neodymium (Nd) in geological samples for high-precision analysis of stable Ce isotopes, and stable and radiogenic Nd isotopes by MC-ICP-MS
    Ding, Weiming
    Zheng, Xin-Yuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (06) : 1583 - 1599
  • [39] High resolution MC-ICP-MS measurements of Fe isotopes in granitoids
    Freydier, R
    Poitrasson, F
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A681 - A681
  • [40] A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Tan, Decan
    Wang, Shui-Jiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1639 - 1651