Development of an ASIC for multi-readout X-ray CCDs

被引:0
|
作者
Matsuura, Daisuke [1 ,2 ]
Nakajima, Hiroshi [1 ,2 ]
Miyata, Emi [1 ,2 ]
Tsunemi, Hiroshi [1 ]
Doty, John P. [3 ]
Ikeda, Hirokazu [4 ]
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, 1-1 Machikaneyama, Osaka 5600043, Japan
[2] Mitsubishi Heavy Ind Co Ltd, Dept Space & Integrated Def Syst, Aichi, Japan
[3] Noqsi Aerosp Ltd, Pine, CO 80470 USA
[4] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Kanagawa, Japan
关键词
charge-coupled device(CCD); X-ray detector; imaging detector; ASIC;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray CCDs have poor timing resolution of several seconds. Since the pixel rate is limited to keep readout noise low, we develop an application specific integrated circuits (ASIC) for multi-readout of X-ray CCDs in order to make the readout circuits small and the power consumption low. Our ASIC with the size of 3 mm x 3 mm has four channels, each channel converts the CCD outputs to 12 bits data employing a delta-sigma(Delta Sigma) digitization. The fabrication process is a 0.35 mu m CMOS technology provided by Taiwan Semiconductor Manufacturing Company (TSMC). The equivalent input noise is about 34 mu V and the power consumption is about 70mW per chip at the pixel rate of 44 kHz. When we use the X-ray CCD whose sensitivity is 3.5 mu V/e(-), the equivalent noise charge is 10 e(-) and the energy resolution is 164 eV(FWHM) at 5.9 keV.
引用
收藏
页码:1073 / 1077
页数:5
相关论文
共 50 条
  • [21] Multilayer X-ray sensitive CCDs
    Skrylev, AS
    Skrylev, PA
    Shilin, VA
    SECOND CONFERENCE ON PHOTONICS FOR TRANSPORTATION, 2002, 4761 : 215 - 225
  • [22] EVENT RECOGNITION IN X-RAY CCDS
    OWENS, A
    MINEO, T
    MCCARTHY, KJ
    WELLS, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 353 - 365
  • [23] Quantum efficiency of X-ray CCDs
    Prigozhin, G
    Woo, J
    Gregory, JA
    Loomis, AH
    Bautz, MW
    Ricker, GR
    Kraft, S
    SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS II, 1998, 3301 : 108 - 115
  • [24] CCDS MAP THE X-RAY SKY
    WELLS, A
    POUNDS, K
    PHYSICS WORLD, 1993, 6 (05) : 32 - 36
  • [25] Development of a pixel readout ASIC for CZT detectors for spectral X-ray photon-counting imaging applications
    Wang, X.
    Deng, Z.
    Liu, W.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [26] X-ray CCDs developed for the joint European X-ray telescope
    Owens, Alan
    Abbey, A.F.
    Brauninger, H.
    Burkert, W.
    Castelli, C.
    Chapman, H.
    Dowson, J.
    Li, Y.
    McCarthy, Kieran J.
    Pool, P.
    Sims, M.R.
    Spragg, J.
    Watson, D.J.
    Wells, A.
    Willingale, R.
    Journal of X-Ray Science and Technology, 1996, 6 (03)
  • [27] CCDs for X-ray topography at synchrotrons
    Castelli, CM
    Allinson, NM
    Barnett, SJ
    Clark, GF
    Moon, K
    Whitehouse, CR
    Wells, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (03): : 481 - 484
  • [28] Design of a Multi-Channel Low-Noise Readout ASIC for CdZnTe-Based X-Ray and γ-Ray Spectrum Analyzer
    Gan, B.
    Wei, T.
    Gao, W.
    Zheng, R.
    Hu, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 1995 - 2002
  • [29] Prototype implementation of a CMOS current mode readout ASIC for X-Ray imaging applications
    Zervakis, E
    Loukas, D
    Haralabidis, N
    Pavlidis, A
    ICECS 2003: PROCEEDINGS OF THE 2003 10TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2003, : 910 - 913
  • [30] Characterization of a New ASIC Readout for Pixel CZT Detectors for Hard X-Ray Astronomy
    Ventura, Giulio
    Caroli, Ezio
    Auricchio, Natalia
    Bertuccio, Giuseppe
    Caccia, Stefano
    Donati, Ariano
    Del Sordo, Stefano
    Schiavone, Filomena
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3656 - 3659