Dynamical characterisation of a miniaturised bulge tester for use at elevated temperatures

被引:2
|
作者
Zschenderlein, U. [1 ]
Zhang, H. [1 ]
Ecke, R. [2 ]
Joehrmann, N. [1 ]
Wunderle, B. [1 ,2 ]
机构
[1] Tech Univ Chemnitz, Chemnitz, Germany
[2] Fraunhofer ENAS, Chemnitz, Germany
关键词
D O I
10.1109/EuroSimE52062.2021.9410834
中图分类号
O414.1 [热力学];
学科分类号
摘要
The bulge test is a standard technique to characterise thin films, but rarely has it been used to impose fatigue damage and extract subcritical thermo-mechanical data. It features, in contrast to many other methods a biaxial stress state. Since bulge testers have usually been used for static tests, dynamic characterisations of such test stands are widely missing. In this paper, we present and discuss the design of a minimized bulge tester for use at elevated temperatures. We measure and discuss the characteristics of the dynamic pressure loading behaviour and provide curves for pressure amplitudes as well as offset pressures. We investigate oscillating membranes with IR cameras and discuss thermal oscillations and cold spots at cracked membranes.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] USE OF FIBER OPTICS IN BIREFRINGENT SENSORS FOR ELEVATED-TEMPERATURES
    REDNER, AS
    PROCEEDINGS OF THE 1989 SEM SPRING CONFERENCE ON EXPERIMENTAL MECHANICS, 1989, : 781 - 781
  • [32] NOVEL ELECTROCHEMICAL HYDROGEN SENSORS FOR USE AT ELEVATED-TEMPERATURES
    DEUBLEIN, G
    LIAW, BY
    HUGGINS, RA
    SOLID STATE IONICS, 1988, 28 : 1660 - 1663
  • [33] THE USE OF LIF FOR DOSIMETRY IN THE MEGAGRAY RANGE AND AT ELEVATED IRRADIATION TEMPERATURES
    WAIBEL, A
    GOKSU, HY
    REGULLA, DF
    RADIATION PROTECTION DOSIMETRY, 1990, 34 (1-4) : 327 - 330
  • [34] SELECTED THERMOPLASTIC BEARING MATERIALS FOR USE AT ELEVATED-TEMPERATURES
    HAGER, AM
    FRIEDRICH, K
    JUNGHANS, R
    WEAR, 1993, 162 (pt B) : 649 - 655
  • [35] ELASTOMERS FOR USE IN DICHLOROTETRAFLUOROETHANE, BRINE, AND OIL AT ELEVATED-TEMPERATURES
    THIBEAU, RJ
    INDUSTRIAL & ENGINEERING CHEMISTRY PRODUCT RESEARCH AND DEVELOPMENT, 1983, 22 (01): : 127 - 131
  • [36] USE OF XENON AND KRYPTON RESONANCE LAMPS AT ELEVATED-TEMPERATURES
    YAKOVLEV, SA
    NEVYAZHSKAYA, IA
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1990, 57 (10): : 639 - 641
  • [37] INFRARED FLOW CELL FOR USE AT ELEVATED-TEMPERATURES AND PRESSURES
    OLTAY, E
    PENNINGER, JM
    ALEMDAROGLU, N
    ALBERIGS, JM
    ANALYTICAL CHEMISTRY, 1973, 45 (04) : 802 - 803
  • [38] Determination of the flow stress of magnesium AZ31-O sheet at elevated temperatures using the hydraulic bulge test
    Kaya, S.
    Altan, T.
    Groche, P.
    Kloepsch, C.
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2008, 48 (05): : 550 - 557
  • [39] Micromechanical characterisation of Sn-Ag-Cu solder FCOB interconnects at ambient and elevated temperatures
    Li, DZ
    Liu, CQ
    Conway, P
    54TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2004, : 128 - 133
  • [40] An automated ash fusion test for characterisation of the behaviour of ashes from biomass and coal at elevated temperatures
    Pang, Cheng Heng
    Hewakandamby, Buddhika
    Wu, Tao
    Lester, Edward
    FUEL, 2013, 103 : 454 - 466