Analysis of photorefractive volume holographic lenses with different recording and read-out wavelengths

被引:1
|
作者
Hu, Zhijuan [1 ]
Yan, Aimin [2 ]
Liu, Dean [2 ]
Liu, Liren [2 ]
机构
[1] Shanghai Normal Univ, Math & Sci Coll, Shanghai 200234, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
来源
OPTIK | 2010年 / 121卷 / 22期
关键词
Photorefractive volume holographic grating; Coupled-wave theory; Diffraction properties; LITHIUM-NIOBATE; GRATINGS; RECONSTRUCTION; STORAGE;
D O I
10.1016/j.ijleo.2009.06.014
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The photorefractive volume holographic lenses for converting a plane wave to a lateral-spread spherical wave with different recording and reconstructing wavelength has been studied. Using the coupled-wave theory, the half-analytical solutions for the amplitudes of the space harmonics of the field inside the transmission geometry are presented. The values of the off-Bragg parameter at the reconstructed process and the diffracted beam's amplitude distribution are analyzed. In addition, the dependences of diffraction properties on the focal length of recording spherical wave and on the geometrical dimensions of the grating are discussed. Furthermore, the focusing properties of this photorefractive holographic lens are analyzed. (C) 2009 Elsevier GmbH. All rights reserved.
引用
收藏
页码:2067 / 2072
页数:6
相关论文
共 50 条
  • [21] ANALYSIS ON READ-OUT SIGNAL IN MAGNETOOPTICAL DISC DRIVE SYSTEM
    LEE, CW
    RIM, KH
    KIM, YW
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (11B): : 5443 - 5444
  • [22] DESIGN OF SUBSTRATE-MODE HOLOGRAPHIC INTERCONNECTS WITH DIFFERENT RECORDING AND READOUT WAVELENGTHS
    AMITAI, Y
    GOODMAN, JW
    APPLIED OPTICS, 1991, 30 (17): : 2376 - 2381
  • [23] Laboratory analysis of influence of methane, on the infrared read-out of volatile anesthetics
    Rolly, G
    Versichelen, L
    ANESTHESIOLOGY, 1996, 85 (3A) : A445 - A445
  • [24] Performance Analysis of Oscillator-Based Read-Out Circuit for LVDT
    Gunasekaran, Vinodhini
    George, Boby
    Aniruddhan, Sankaran
    Janardhanan, Dhurga Devi
    Palur, Ramakrishna Venkatraman
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (04) : 1080 - 1088
  • [25] ANALYSIS OF PHOTOREFRACTIVE STRATIFIED VOLUME HOLOGRAPHIC OPTICAL-ELEMENTS
    DEVRE, R
    HESSELINK, L
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1994, 11 (09) : 1800 - 1808
  • [26] Surface plasmon polariton coupling between nano recording marks and their effect on optical read-out signal
    Kuo Pin Chiu
    Kuei Fu Lai
    Shih Chiang Yen
    Din Ping Tsai
    Optical Review, 2009, 16 : 326 - 331
  • [27] Surface plasmon polariton coupling between nano recording marks and their effect on optical read-out signal
    Chiu, Kuo Pin
    Lai, Kuei Fu
    Yen, Shih Chiang
    Tsai, Din Ping
    OPTICAL REVIEW, 2009, 16 (03) : 326 - 331
  • [28] RECORDING AND READ-OUT OF THIN REFLECTING DYNAMIC HOLOGRAMS NEAR THE INTERFACE OF METAL DIELECTRIC-PAIR
    KOROLEV, AE
    NAZAROV, VN
    STASELKO, DI
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 15 (20): : 87 - 92
  • [29] CHARACTERISTIC PROPERTIES OF IMAGE PARTIAL RECONSTRUCTION IN READ-OUT OF DIFFUSE-OBJECT VOLUME HOLOGRAMS
    KAPITANOV, AV
    OPTIKA I SPEKTROSKOPIYA, 1991, 70 (04): : 850 - 855
  • [30] Comparison of potency assays using different read-out systems and their suitability for quality control
    Zumpe, C.
    Bachmann, C. L.
    Metzger, A. U.
    Wiedemann, N.