Pulmonary artery catheter knot in a liver transplantation, a rare complication

被引:0
|
作者
Silva, Felipe L. [1 ]
Gomes, Jose L. U. M. [1 ]
Boas, Walkiria W., V [1 ]
de Freitas, Gabriela, V [1 ]
机构
[1] Univ Fed Minas Gerais, Clin Hosp, Dept Anesthesiol, Belo Horizonte, MG, Brazil
关键词
Complications; hemodynamic monitoring; pulmonary artery catheter; pulmonary artery catheter knot formation; Swan-Ganz catheter;
D O I
10.4103/sja.sja_711_21
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The pulmonary artery catheter (PAC) measures hemodynamic parameters in real time, providing valuable data for the management of the critical patient. Nevertheless, its use is associated with several complications. Knot formation is a rare complication related to PAC insertion. A 51-year-old patient with complicated ethanolic liver cirrhosis underwent orthotopic liver transplantation. Invasive hemodynamic monitoring was performed using a Swan-Ganz pulmonary artery catheter (PAC) inserted through the right internal jugular vein. Chest X-ray in the immediate postoperative period showed the presence of a possible knot adjacent to the tip of the sheath in the internal jugular vein. The patient was then referred to the hemodynamics room, where, through fluoroscopy, a true knot was successfully removed after femoral vein dissection. The medical team should weigh the risk and benefit of using the PAC, taking into account the patient's clinical conditions, the benefits, and possible complications of the procedure.
引用
收藏
页码:478 / 480
页数:3
相关论文
共 50 条
  • [41] Management of Hepatic Artery Complication after Liver Transplantation
    Liu, Chun-Yi
    Chen, Chao-Long
    Wang, Chih-Chi
    Wang, Shih-Ho
    Concejero, Allan M.
    Lin, Chih-Che
    Liu, Yeuh-Wei
    Yong, Chee-Chien
    Lee, Wei-Feng
    Lin, Ting-Lung
    Lin, Jong-Yueh
    Yap, Anthony Q.
    Jawade, Kailash
    LIVER TRANSPLANTATION, 2010, 16 (06) : S212 - S212
  • [42] Hemodynamic-volumetric versus pulmonary artery catheter monitoring during anesthesia for liver transplantation
    Della Rocca, G
    Pompei, L
    Costa, MG
    Coccia, C
    Rossi, M
    Berloco, PM
    Pietropaoli, P
    Cortesini, R
    TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) : 1394 - 1396
  • [43] IRREMOVABLE EPIDURAL CATHETER DUE TO A SLING AND A KNOT A RARE COMPLICATION OF EPIDURAL-ANESTHESIA IN OBSTETRICS
    RIEGLER, R
    PERNETZKY, A
    ANAESTHESIST, 1983, 32 (01): : A19 - A20
  • [44] Tuberculous Liver Abscess: A Rare Complication aft er Liver Transplantation
    Machicado, Jorge D.
    Nevah, Moises
    Machicao, Victor I.
    Lopez, Francisco
    Pan, Jen J.
    Fallon, Michael
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 : S443 - S444
  • [45] Unusual Complication of Pulmonary Artery Catheter Placement; Entanglement with ICD Leads
    Biru, N.
    Zaaqoq, A. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [46] FROZEN PULMONARY-ARTERY CATHETER - A COMPLICATION ASSOCIATED WITH CRYOABLATION OF THE VENTRICLE
    ZAHL, K
    MURRAY, T
    JOBES, DR
    ANESTHESIOLOGY, 1986, 64 (05) : 662 - 663
  • [47] A rare complication of port catheter
    Kiral, Nesrin
    Sarac, Gulsen
    Yuksel, Tugba
    Salepci, Banu
    Caglayan, Benan
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2010, 58 (02): : 177 - 180
  • [48] A rare complication of epidural catheter
    Bigat, Z
    Boztug, N
    Onder, G
    Ertok, E
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (04) : 589 - U1
  • [49] Pulmonary Artery Pseudoaneurysm: A Rare Complication After Suction Thrombectomy
    Watson, Madeline
    Srivali, Narat
    ARCHIVOS DE BRONCONEUMOLOGIA, 2025, 61 (02): : 113 - 114
  • [50] Occlusion of the right Pulmonary artery as a rare Complication of a dissecting Aorta
    Sabou, T.
    Kamusella, P.
    Andresen, R.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (12): : 1161 - U65